Digital pulse shape analysis for the capture-gated liquid scintillator BC-523A

被引:27
作者
Flaska, Marek [1 ]
Pozzi, Sara A. [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Capture-gated detector; Liquid scintillator; Neutron spectroscopy; Special nuclear material; PLASTIC SCINTILLATOR; FAST-NEUTRONS; GAMMA-RAYS; DISCRIMINATION; SPECTROMETER;
D O I
10.1016/j.nima.2008.10.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The BC-523A detector is a boron-10-loaded liquid scintillation detector that is sensitive to not only fast neutrons and gamma rays, but also to thermal neutrons. This detector has recently attracted the attention of several researchers and has shown promise for neutron spectroscopy. Several efforts have been made to accurately characterize this detector for several neutron and gamma-ray energies. In this paper, we show, for the first time, that neutron capture pulses can be visually distinguished from neutron scattering pulses by using an offline digital pulse shape discrimination method based on charge integration. In addition, new Monte Carlo simulation and measurement results for time to capture are compared and reasonable agreement is achieved. This work has applications in fields such as nuclear safeguards, nuclear nonproliferation, and national security. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 17 条
[1]   ENERGY RESPONSE OF A FULL-ENERGY-ABSORPTION NEUTRON SPECTROMETER USING BORON-LOADED LIQUID SCINTILLATOR BC-523 [J].
AOYAMA, T ;
HONDA, K ;
MORI, C ;
KUDO, K ;
TAKEDA, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 333 (2-3) :492-501
[2]   Development of a handheld device for simultaneous monitoring of fast neutrons and gamma rays [J].
Aryaeinejad, R ;
Reber, EL ;
Spencer, DF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1909-1913
[3]   An approach to multiplicity counting for a versatile new sensor for plutonium assay with a very short die-away time, and independent measurements of neutrons and gamma rays [J].
Belian, AP ;
Browne, MC ;
Clay, W ;
Ensslin, N ;
Geist, W ;
Nguyen, H ;
Ianakiev, K ;
Mayo, D ;
Panowski, S ;
Russo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) :54-57
[4]   INTEGRAL TEST OF A B-10 LOADED LIQUID SCINTILLATOR FOR NEUTRON DETECTION [J].
CHOU, HP ;
HORNG, CY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 328 (03) :522-525
[5]  
CZIRR JB, 1994, NUCL INSTRUM METH A, V349, P532, DOI 10.1016/0168-9002(94)91222-X
[6]   Capture-gated neutron spectrometry [J].
Czirr, JB ;
Merrill, DB ;
Buehler, D ;
McKnight, TK ;
Carroll, JL ;
Abbott, T ;
Wilcox, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :309-312
[7]   NEW ELECTRONICALLY BLACK NEUTRON DETECTORS [J].
DRAKE, DM ;
FELDMAN, WC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 247 (03) :576-582
[8]   Identification of shielded neutron sources with the liquid scintillator BC-501A using a digital pulse shape discrimination method [J].
Flaska, M. ;
Pozzi, S. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 577 (03) :654-663
[9]   Digital techniques for n/γ pulse shape discrimination and capture-gated neutron spectroscopy using liquid scintillators [J].
Jastaniah, SD ;
Sellin, PJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3) :202-210
[10]  
KNOLL GF, 2000, RAD DETECTION MEASUR, P570