Enhanced capillary performance in axially grooved aluminium wicks by alkaline corrosion treatment

被引:37
作者
Huang, Guanghan [1 ,2 ]
Yuan, Wei [1 ]
Tang, Yong [1 ]
Zhang, Bin [1 ]
Zhang, Shiwei [1 ]
Lu, Longsheng [1 ]
机构
[1] South China Univ Technol, Sch Mech & Automot Engn, Key Lab Surface Funct Struct Mfg, Guangdong Higher Educ Inst, Wushan Rd, Guangzhou 510640, Guangdong, Peoples R China
[2] Univ South Carolina, Dept Mech Engn, Columbia, SC 29208 USA
关键词
Grooved aluminium wick; Capillary performance; Alkaline corrosion treatment; Capillary limit; HEAT-TRANSFER DEVICES; COMPOSITE WICKS; PIPE ARRAYS; COLLECTOR;
D O I
10.1016/j.expthermflusci.2016.11.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an alkaline corrosion treatment for axially grooved aluminium wicks, which significantly enhances the capillary performance of these wicks and increases the applicability of axially grooved aluminium heat pipes in space or in a horizontal direction. The effect of corrosion parameters (molar concentration and reaction time) on the capillary performance was investigated. An IR camera was used to build a capillary rate-of-rise test apparatus to measure the capillary performance of corroded wicks. Experimental results indicate that the corroded-aluminium grooved wicks always present higher capillary pressures than non-corroded ones. However, care should be taken to control the molar concentration and reaction time such that the best capillary performance can be achieved. In this study, the optimal corrosion parameters were found to be 1.25 mol/L NaOH for 10 min (noted as N1.25-10), which resulted in the best capillary performance parameter (Delta P-cap.K) of 8.97 +/- 0,38 x 10(-7) N. This finding demonstrated an enhancement of 155% compared with the value of 3.51 +/- 0.1 x 10(-7) N for the non corroded wicks. Furthermore, a novel prediction method was proposed to calculate.the capillary heat transfer limit of heat pipes based on IR rate-of-rise tests on wicks. The calculated corresponding heat pipe capillary limit (Q(C), max) of the sample N1.25-10 reached the maximum value of 9.00 W +/- 4.25%, far exceeding the value of 3.52 W +/- 1.5% for the non-corroded wicks. The underlying mechanism of the enhancement is associated with the micro-coarse-structured morphology and improved hydrophilicity of the corroded aluminium surface. This study demonstrates that alkaline corrosion treatment is an easy and effective way to improve the capillary performance of grooved aluminium wicks and the capillary heat transfer limit of grooved aluminium heat pipes. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:212 / 221
页数:10
相关论文
共 25 条
  • [1] Elaboration of thermal control systems on heat pipes for microsatellites Magion 4, 5 and BIRD
    Baturkin, V
    Zhuk, S
    Vojta, J
    Lura, F
    Biering, B
    Lötzke, HG
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (09) : 1109 - 1117
  • [2] Bilegan I.C., 1983, P 4 INT HEAT PIP C, P89
  • [3] Chi S.W., 1976, HEAT PIPE THEORY PRA
  • [4] Deepa P., 2014, ARABIAN J CHEM
  • [5] Evaluation of capillary performance of sintered porous wicks for loop heat pipe
    Deng, Daxiang
    Liang, Dejie
    Tang, Yong
    Peng, Jiemin
    Han, Xiaodong
    Pan, Minqiang
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 50 : 1 - 9
  • [6] Characterization of capillary performance of composite wicks for two-phase heat transfer devices
    Deng, Daxiang
    Tang, Yong
    Huang, Guanghan
    Lu, Longsheng
    Yuan, Dong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 56 (1-2) : 283 - 293
  • [7] Experimental study of the performance for a novel kind of MHPA-FPC solar water heater
    Deng, Yuechao
    Wang, Wei
    Zhao, Yaohua
    Yao, Liang
    Wang, Xinyue
    [J]. APPLIED ENERGY, 2013, 112 : 719 - 726
  • [8] Experimental investigation of performance for the novel flat plate solar collector with micro-channel heat pipe array (MHPA-FPC)
    Deng, Yuechao
    Zhao, Yaohua
    Wang, Wei
    Quan, Zhenhua
    Wang, Lincheng
    Yu, Dan
    [J]. APPLIED THERMAL ENGINEERING, 2013, 54 (02) : 440 - 449
  • [9] Dunn P.D., 2012, HEAT PIPES
  • [10] Faghri Amir., 1995, HEAT PIPE SCI TECHNO