Estimation of spatio-temporal parameters of gait from magneto-inertial measurement units: multicenter validation among Parkinson, mildly cognitively impaired and healthy older adults

被引:61
作者
Bertoli, Matilde [1 ,2 ]
Cereatti, Andrea [1 ,2 ,3 ]
Trojaniello, Diana [4 ]
Avanzino, Laura [5 ,6 ]
Pelosin, Elisa [7 ]
Del Din, Silvia [8 ]
Rochester, Lynn [8 ,9 ]
Ginis, Pieter [10 ]
Bekkers, Esther M. J. [10 ,11 ]
Mirelman, Anat [12 ,13 ,14 ]
Hausdorff, Jeffrey M. [12 ,13 ,14 ,15 ,16 ]
Della Croce, Ugo [1 ,2 ]
机构
[1] Univ Sassari, Dept Biomed Sci, Sassari, Italy
[2] Interuniv Ctr Bioengn Human Neuromusculoskeletal, Sassari, Italy
[3] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
[4] Osped San Raffaele, E Serv Life & Hlth, Milan, Italy
[5] Univ Genoa, Sect Human Physiol, Dept Expt Med, Genoa, Italy
[6] Univ Genoa, Ctr Polifunz Sci Motorie, Genoa, Italy
[7] Univ Genoa, Dept Neurosci Rehabil Ophthalmol Genet & Maternal, Genoa, Italy
[8] Newcastle Univ, Inst Neurosci, Inst Ageing, Clin Ageing Res Unit, Campus Ageing & Vital, Newcastle, England
[9] Newcastle Upon Tyne Hosp NHS Fdn Trust, Newcastle, England
[10] Katholieke Univ Leuven, Dept Rehabil Sci, Neuromotor Rehabil Res Grp, Louvain, Belgium
[11] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, Dept Neurol,Parkinson Ctr Nijmegen, Nijmegen, Netherlands
[12] Tel Aviv Sourasky Med Ctr, Ctr Study Movement Cognit & Mobil, Neurol Inst, Tel Aviv, Israel
[13] Tel Aviv Univ, Sagol Sch Neurosci, Tel Aviv, Israel
[14] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[15] Rush Univ, Med Ctr, Rush Alzheimers Dis Ctr, Tel Aviv, Israel
[16] Rush Univ, Med Ctr, Dept Orthopaed Surg, Tel Aviv, Israel
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
关键词
Clinical gait analysis; Spatial and temporal gait parameters; Magneto-inertial sensors; Wearable sensors; Parkinson; Elderly; Multicentric study; CONVOLUTIONAL NEURAL-NETWORKS; STRIDE LENGTH; FALL RISK; SENSORS; SYSTEM; FOOT; TIME;
D O I
10.1186/s12938-018-0488-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The use of miniaturized magneto-inertial measurement units (MIMUs) allows for an objective evaluation of gait and a quantitative assessment of clinical outcomes. Spatial and temporal parameters are generally recognized as key metrics for characterizing gait. Although several methods for their estimate have been proposed, a thorough error analysis across different pathologies, multiple clinical centers and on large sample size is still missing. The aim of this study was to apply a previously presented method for the estimate of spatio-temporal parameters, named Trusted Events and Acceleration Direct and Reverse Integration along the direction of Progression (TEADRIP), on a large cohort (236 patients) including Parkinson, mildly cognitively impaired and healthy older adults collected in four clinical centers. Data were collected during straight-line gait, at normal and fast walking speed, by attaching two MIMUs just above the ankles. The parameters stride, step, stance and swing durations, as well as stride length and gait velocity, were estimated for each gait cycle. The TEADRIP performance was validated against data from an instrumented mat. Results: Limits of agreements computed between the TEADRIP estimates and the reference values from the instrumented mat were -27 to 27 ms for Stride Time, -68 to 44 ms for Stance Time, -31 to 31 ms for Step Time and -67 to 52 mm for Stride Length. For each clinical center, the mean absolute errors averaged across subjects for the estimation of temporal parameters ranged between 1 and 4%, being on average less than 3% (< 30 ms). Stride length mean absolute errors were on average 2% (approximate to 25 mm). Error comparisons across centers did not show any significant difference. Significant error differences were found exclusively for stride and step durations between healthy elderly and Parkinsonian subjects, and for the stride length between walking speeds. Conclusions: The TEADRIP method was effectively validated on a large number of healthy and pathological subjects recorded in four different clinical centers. Results showed that the spatio-temporal parameters estimation errors were consistent with those previously found on smaller population samples in a single center. The combination of robustness and range of applicability suggests the use of the TEADRIP as a suitable MIMU-based method for gait spatio-temporal parameter estimate in the routine clinical use. The present paper was awarded the "SIAMOC Best Methodological Paper 2017".
引用
收藏
页数:14
相关论文
共 35 条
  • [21] V-TIME: a treadmill training program augmented by virtual reality to decrease fall risk in older adults: study design of a randomized controlled trial
    Mirelman, Anat
    Rochester, Lynn
    Reelick, Miriam
    Nieuwhof, Freek
    Pelosin, Elisa
    Abbruzzese, Giovanni
    Dockx, Kim
    Nieuwboer, Alice
    Hausdorff, Jeffrey M.
    [J]. BMC NEUROLOGY, 2013, 13
  • [22] Gait Alterations in Healthy Carriers of the LRRK2 G2019S Mutation
    Mirelman, Anat
    Gurevich, Tanya
    Giladi, Nir
    Bar-Shira, Anat
    Orr-Urtreger, Avi
    Hausdorff, Jeffrey M.
    [J]. ANNALS OF NEUROLOGY, 2011, 69 (01) : 193 - 197
  • [23] Estimation of stride length in level walking using an inertial measurement unit attached to the foot: A validation of the zero velocity assumption during stance
    Peruzzi, A.
    Della Croce, U.
    Cereatti, A.
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (10) : 1991 - 1994
  • [24] Algorithm for Turning Detection and Analysis Validated under Home-Like Conditions in Patients with Parkinson's Disease and Older Adults using a 6 Degree-of-Freedom Inertial Measurement Unit at the Lower Back
    Pham, Minh H.
    Elshehabi, Morad
    Haertner, Linda
    Heger, Tanja
    Hobert, Markus A.
    Faber, Gert S.
    Salkovic, Dina
    Ferreira, Joaquim J.
    Berg, Daniela
    Sanchez-Ferro, Alvaro
    van Dieen, Jaap H.
    Maetzler, Walter
    [J]. FRONTIERS IN NEUROLOGY, 2017, 8
  • [25] A spot check for assessing static orientation consistency of inertial and magnetic sensing units
    Picerno, Pietro
    Cereatti, Andrea
    Cappozzo, Aurelio
    [J]. GAIT & POSTURE, 2011, 33 (03) : 373 - 378
  • [26] Fourier-based integration of quasi-periodic gait accelerations for drift-free displacement estimation using inertial sensors
    Sabatini, Angelo Maria
    Ligorio, Gabriele
    Mannini, Andrea
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [27] Gait assessment in Parkinson's disease: Toward an ambulatory system for long-term monitoring
    Salarian, A
    Russmann, H
    Vingerhoets, FJG
    Dehollain, C
    Blanc, Y
    Burkhard, PR
    Aminian, K
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (08) : 1434 - 1443
  • [28] Sijobert B., 2015, Health, V7, P704, DOI [10.4236/health.2015.76084, DOI 10.4236/HEALTH.2015.76084]
  • [29] Quantification of human motion: gait analysis - benefits and limitations to its application to clinical problems
    Simon, SR
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (12) : 1869 - 1880
  • [30] An Ambulatory Gait Monitoring System with Activity Classification and Gait Parameter Calculation Based on a Single Foot Inertial Sensor
    Song, Minsu
    Kim, Jonghyun
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (04) : 885 - 893