MULTICRITERIA OPTIMIZATION IN INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR LOCALLY ADVANCED CANCER OF THE PANCREATIC HEAD

被引:69
|
作者
Hong, Theodore S. [1 ,2 ]
Craft, David L. [1 ,2 ]
Carlsson, Fredrik [3 ]
Bortfeld, Thomas R. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] RaySearch Labs, Stockholm, Sweden
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 72卷 / 04期
关键词
Pancreatic cancer; Multicriteria optimization; IMRT;
D O I
10.1016/j.ijrobp.2008.07.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Intensity-modulated radiation therapy (IMRT) affords the potential to decrease radiation therapy-associated toxicity by creating highly conformal dose distributions. However, the inverse planning process can create a suboptimal plan despite meeting all constraints. Multicriteria optimization (MCO) may reduce the time-consuming iteration loop necessary to develop a satisfactory plan while providing information regarding trade-offs between different treatment planning goals. In this exploratory study, we examine the feasibility and utility of MCO in physician plan selection in patients with locally advanced pancreatic cancer (LAPC). Methods and Materials: The first 10 consecutive patients with LAPC treated with IMRT were evaluated. A database of plans (Pareto surface) was created that met the inverse planning goals. The physician then navigated to an "optimal" plan from the point on the Pareto surface at which kidney dose was minimized. Results: Pareto surfaces were created for all 10 patients. A physician was able to select a plan from the Pareto surface within 10 minutes for all cases. Compared with the original (treated) IMRT plans, the plan selected from the Pareto surface had a lower stomach mean dose in 9 of 10 patients, although often at the expense of higher kidney dose than with the treated plan. Conclusion: The MCO is feasible in patients with LAPC and allows the physician to choose a satisfactory plan quickly. Generally, when given the opportunity, the physician will choose a plan with a lower stomach dose. The MCO enables a physician to provide greater active clinical input into the IMRT planning process. (c) 2008 Elsevier Inc.
引用
收藏
页码:1208 / 1214
页数:7
相关论文
共 50 条
  • [31] Evaluation of Dynamic Tumor-tracking Intensity-modulated Radiotherapy for Locally Advanced Pancreatic Cancer
    Nakamura, Akira
    Hiraoka, Masahiro
    Itasaka, Satoshi
    Nakamura, Mitsuhiro
    Akimoto, Mami
    Ishihara, Yoshitomo
    Mukumoto, Nobutaka
    Goto, Yoko
    Kishi, Takahiro
    Yoshimura, Michio
    Matsuo, Yukinori
    Yano, Shinsuke
    Mizowaki, Takashi
    SCIENTIFIC REPORTS, 2018, 8
  • [32] Dental radiation dosimetric maps from intensity-modulated radiation therapy planning for head and neck cancers
    Polce, Simran
    Gogineni, Emile
    Antone, Jeffrey
    Ghaly, Maged
    Keith Frank, Douglas
    Segal, Joshua D.
    Parashar, Bhupesh
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (05): : 1428 - 1439
  • [33] A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer
    Fan, Y.
    Qiu, G.
    Pan, Q.
    Zhang, F.
    Luan, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (01): : 185 - 189
  • [34] Intensity-modulated radiation therapy in head and neck cancers: An update
    Lee, Nancy
    Puri, Dev R.
    Blanco, Angel I.
    Chao, K. S. Clifford
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2007, 29 (04): : 387 - 400
  • [35] TREATMENT OF LOCALLY ADVANCED PANCREATIC CANCER: THE ROLE OF RADIATION THERAPY
    Johung, Klmberly
    Saif, Muhammad Wasif
    Chang, Bryan W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 508 - 518
  • [36] A Two-Stage Programming Approach to Fluence Map Optimization for Intensity-Modulated Radiation Therapy Treatment Planning
    Rocha, Humberto
    Dias, Joana M.
    Ferreira, Brigida C.
    Lopes, Maria Do Carmo
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 687 - 690
  • [37] A comparative analysis between sequential boost and integrated boost intensity-modulated radiation therapy with concurrent chemotherapy for locally-advanced head and neck cancer
    Vlacich, Gregory
    Stavas, Mark J.
    Pendyala, Praveen
    Chen, Shaeu-Chiann
    Shyr, Yu
    Cmelak, Anthony J.
    RADIATION ONCOLOGY, 2017, 12
  • [38] Intensity-modulated radiation therapy for patients with rectal cancer
    Vuong, Te
    Garant, Aurelie
    Gallant, Fleure
    COLORECTAL CANCER, 2014, 3 (03) : 235 - 238
  • [39] Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer
    Sarah Stefanowicz
    Kristin Stützer
    Sebastian Zschaeck
    Annika Jakobi
    Esther G. C. Troost
    Radiation Oncology, 13
  • [40] Dosimetric and clinical toxicity comparison of critical organ preservation with three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and RapidArc for the treatment of locally advanced cancer of the pancreatic head
    Jin, L.
    Wang, R.
    Jiang, S.
    Yue, J.
    Liu, T.
    Dou, X.
    Zhu, K.
    Feng, R.
    Xu, X.
    Chen, D.
    Yin, Y.
    CURRENT ONCOLOGY, 2016, 23 (01) : E41 - E48