Air quality impacts and health-benefit valuation of a low-emission technology for rail yard locomotives in Atlanta Georgia

被引:14
作者
Galvis, Boris [1 ,2 ]
Bergin, Michael [1 ,3 ]
Boylan, James [4 ]
Huang, Yan [4 ]
Bergin, Michelle [3 ]
Russell, Armistead G. [1 ]
机构
[1] Georgia Inst Technol, Atlanta, GA 30332 USA
[2] La Salle Univ, Bogota, Colombia
[3] Duke Univ, Durham, NC USA
[4] Georgia Dept Nat Resources, Air Protect Branch, Environm Protect Div, Atlanta, GA USA
关键词
Atlanta; Georgia; Rail yard locomotive emissions; Health impacts; Black carbon; Dispersion modeling; Cost benefit; FINE PARTICULATE MATTER; LUNG-CANCER; UNITED-STATES; FOLLOW-UP; POLLUTION; MORTALITY; DISEASE; RISK;
D O I
10.1016/j.scitotenv.2015.06.064
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One of the largest rail yard facilities in the Southeastern US, the Inman and Tilford yards, is located in the northwestern section of Atlanta, Georgia alongside other industries, schools, businesses, and dwellings. It is a significant source of fine particulate (PM2.5) and black carbon (BC) (Galvis, Bergin, & Russell, 2013). We calculate 2011 PM2.5 and BC emissions from the rail yards and primary industrial and on-road mobile sources in the area and determine their impact on local air quality using Gaussian dispersion modeling. We determine the change in PM2.5 and BC concentrations that could be accomplished by upgrading traditional switcher locomotives used in these rail yards to a lower emitting technology and evaluate the health benefits for comparison with upgrade costs. Emissions from the rail yards were estimated using reported fuel consumption data (GAEPD, 2012b) and emission factors previously measured in the rail yards (Galvis et al., 2013). Model evaluation against 2011 monitoring data found agreement between measured and simulated concentrations. Model outputs indicate that the line-haul and switcher activities are responsible for increments in annual average concentrations of approximately 0.5 +/- 0.03 mu g/m(3) (39%) and 0.7 +/- 0.04 mu g/m(3) (56%) of BC, and for 1.0 +/- 0.1 mu g/m(3) (7%) and 1.6 +/- 0.2 mu g/m(3) (14%) of PM2.5 at two monitoring sites located north and south of the rail yards respectively. Upgrading the switcher locomotives at the yards with a lower emitting technology in this case "mother slug" units could decrease PM2.5 and BC emissions by about 9 and 3 t/year respectively. This will lower annual average PM2.5 concentrations between 0.3 +/- 0.1 mu g/m(3) and 0.6 +/- 0.1 mu g/m(3) and BC concentrations between 0.1 +/- 0.02 mu g/m(3) and 0.2 +/- 0.03 mu g/m(3) at monitoring sites north and south of the rail yards respectively, and would facilitate PM2.5 NAAQS attainment in the area. We estimate that health benefits of approximately 20 million dollars per year could be gained. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 57 条
[1]  
ABT A, 2012, BENMAP ENV BEN MAPP
[2]  
[Anonymous], 1992, CBMS-NSF Reg. Conf. Ser. in Appl. Math
[3]  
[Anonymous], 2012, REP C BLACK CARB
[4]  
ARC, 2011, ATL REG COMM LINK BA
[5]  
ARCADIS, 2005, BOLT MOOR MILL TRANS
[6]   Daily sampling of PM2.5 in Atlanta:: results of the first year of the assessment of spatial aerosol composition in Atlanta study -: art. no. 8415 [J].
Butler, AJ ;
Andrew, MS ;
Russell, AG .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D1)
[7]  
Campbell D., 2009, ROSEVILLE RAIL YARD
[8]  
CARB, 2011, RAIL HLTH RISK ASS M
[9]  
Census B., 2010, POP HOUS CENS
[10]   Grand challenges for high-speed rail environmental assessment in the United States [J].
Chester, Mikhail V. ;
Ryerson, Megan S. .
TRANSPORTATION RESEARCH PART A-POLICY AND PRACTICE, 2014, 61 :15-26