Functional MRI of the kidney: tools for translational studies of pathophysiology of renal disease

被引:92
作者
Prasad, PV [1 ]
机构
[1] Evanston NW Healthcare, Dept Radiol, Evanston, IL 60201 USA
关键词
perfusion; renal function; blood oxygenation level-dependent; human; contrast agent;
D O I
10.1152/ajprenal.00114.2005
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Magnetic resonance imaging (MRI) provides exquisite anatomic detail of various organs and is capable of providing additional functional information. This combination allows for comprehensive diagnostic evaluation of pathologies such as ischemic renal disease. Noninvasive MRI techniques could facilitate translation of many studies performed in controlled animal models using technologies that are invasive to humans. Such a translation is being recognized as essential because many proposed interventions and drugs that prove efficacious in animal models fail to do so in humans. In this article, we review the state-of-the-art functional MRI technique as applied to the kidneys.
引用
收藏
页码:F958 / F974
页数:17
相关论文
共 157 条
[1]   Correlation of quantitative dynamic magnetic resonance imaging findings with pathology results in renal transplants: A preliminary report [J].
Agildere, AM ;
Tarhan, NC ;
Bozdagi, G ;
Demirag, A ;
Niron, EA ;
Haberal, M .
TRANSPLANTATION PROCEEDINGS, 1999, 31 (08) :3312-3316
[2]   NITRIC-OXIDE AND PROSTANOIDS PROTECT THE RENAL OUTER MEDULLA FROM RADIOCONTRAST TOXICITY IN THE RAT [J].
AGMON, Y ;
PELEG, H ;
GREENFELD, Z ;
ROSEN, S ;
BREZIS, M .
JOURNAL OF CLINICAL INVESTIGATION, 1994, 94 (03) :1069-1075
[3]   DISPARATE EFFECTS OF ADENOSINE-A(1)-RECEPTOR AND A(2)-RECEPTOR AGONISTS ON INTRARENAL BLOOD-FLOW [J].
AGMON, Y ;
DINOUR, D ;
BREZIS, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (06) :F802-F806
[4]  
AGMON Y, 1993, EXP NEPHROL, V1, P357
[5]  
Ahmed Manzoor, 2004, Semin Vasc Surg, V17, P181, DOI 10.1053/j.semvascsurg.2004.03.013
[6]   Detection of acute renal ischemia in swine using blood oxygen level-dependent magnetic resonance imaging [J].
Alford, SK ;
Sadowski, EA ;
Unal, O ;
Polzin, JA ;
Consigny, DW ;
Korosec, FR ;
Grist, TM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) :347-353
[7]  
[Anonymous], 1993, CEREBRAL BLOOD FLOW
[8]   Theory of spin-exchange optical pumping of 3He and 129Xe [J].
Appelt, S ;
Baranga, AB ;
Erickson, CJ ;
Romalis, MV ;
Young, AR ;
Happer, W .
PHYSICAL REVIEW A, 1998, 58 (02) :1412-1439
[9]   Quantification of renal perfusion using an intravascular contrast agent (Part 1): Results in a canine model [J].
Aumann, S ;
Schoenberg, SO ;
Just, A ;
Briley-Saebo, K ;
Bjornerud, A ;
Bock, M ;
Brix, G .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) :276-287
[10]   Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI [J].
Baumann, D ;
Rudin, M .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :587-595