This paper presents an implantable microsystem for tonometric blood pressure measurement in small animals. The microsystem consists of four major components: (1) a titanium base for supporting a pressure sensor and an interface chip, (2) a micromachined capacitive pressure sensor array, (3) a switched-capacitor interface chip, and (4) a titanium cap. A new micromachining fabrication process has been developed to create capacitive pressure transducers with a flat surface necessary for tonometric pressure measurement. An array of three capacitive sensors is used to increase signal output and improve stability. A custom-designed switched-capacitor CMOS interface circuit is used to measure changes in capacitance. In vitro calibration tests have been performed on the complete cuff using a silastic tube to mimic a pliable blood vessel. A sensitivity of 2 mV/mmHg @ 100 mmHg and a resolution of 0.5 mmHg (based on 1 mV RMS interface chip noise floor) has been obtained. The dimensions of the cuff system 10(L) x 6.5(W) x 3(11) mm(3).
引用
收藏
页码:285 / 292
页数:8
相关论文
共 50 条
[41]   Continuous blood pressure measurement based on photoplethysmography [J].
Chen Yi ;
Cheng Jian ;
Ji Wenqiang .
PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, :1656-1663
[42]   The oscillometric blood pressure measurement - mathematical modeling [J].
Juroszek, Barbara .
PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12) :304-307
[43]   Arm position is important for blood pressure measurement [J].
RT Netea ;
JWM Lenders ;
P Smits ;
T Thien .
Journal of Human Hypertension, 1999, 13 :105-109
[44]   Blood pressure measurement in special populations and circumstances [J].
Stergiou, George S. ;
Dolan, Eamon ;
Kollias, Anastasios ;
Poulter, Neil R. ;
Shennan, Andrew ;
Staessen, Jan A. ;
Zhang, Zhen-Yu ;
Weber, Michael A. .
JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07) :1122-1127
[45]   The great myth of office blood pressure measurement [J].
Myers, Martin G. .
JOURNAL OF HYPERTENSION, 2012, 30 (10) :1894-1898
[46]   Standardized blood pressure measurement in clinical practice [J].
Eckert S. ;
Grabfelder M. .
MMW - Fortschritte der Medizin, 2017, 159 (9) :67-68
[47]   Blood pressure measurement during exercise: A review [J].
Griffin, SE ;
Robergs, RA ;
Heyward, VH .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (01) :149-159
[48]   Arm position is important for blood pressure measurement [J].
Netea, RT ;
Lenders, JWM ;
Thien, T .
JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (02) :105-109
[49]   Implications of Blood Pressure Measurement Technique for Implementation of Systolic Blood Pressure Intervention Trial (SPRINT) [J].
Agarwal, Rajiv .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (02)
[50]   Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure [J].
Davies, JI ;
Band, MM ;
Pringle, S ;
Ogston, S ;
Struthers, AD .
JOURNAL OF HYPERTENSION, 2003, 21 (03) :571-576