An Implantable Microsystem for Tonometric Blood Pressure Measurement

被引:41
作者
Ziaie, Babak [1 ]
Najafi, Khalil [2 ,3 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Michigan, Dept Elect Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Comp Sci Ctr Integrated Microsyst, Ann Arbor, MI 48109 USA
基金
美国国家航空航天局;
关键词
implantable microsystems; tonometry; bioMEMS; biomedical microdevices; blood pressure measurement; biomedical transducers;
D O I
10.1023/A:1012452613720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable microsystem for tonometric blood pressure measurement in small animals. The microsystem consists of four major components: (1) a titanium base for supporting a pressure sensor and an interface chip, (2) a micromachined capacitive pressure sensor array, (3) a switched-capacitor interface chip, and (4) a titanium cap. A new micromachining fabrication process has been developed to create capacitive pressure transducers with a flat surface necessary for tonometric pressure measurement. An array of three capacitive sensors is used to increase signal output and improve stability. A custom-designed switched-capacitor CMOS interface circuit is used to measure changes in capacitance. In vitro calibration tests have been performed on the complete cuff using a silastic tube to mimic a pliable blood vessel. A sensitivity of 2 mV/mmHg @ 100 mmHg and a resolution of 0.5 mmHg (based on 1 mV RMS interface chip noise floor) has been obtained. The dimensions of the cuff system 10(L) x 6.5(W) x 3(11) mm(3).
引用
收藏
页码:285 / 292
页数:8
相关论文
共 50 条
[31]   What is the accuracy of clinic blood pressure measurement? [J].
Sala, C ;
Santin, E ;
Rescaldani, M ;
Cuspidi, C ;
Magrini, F .
AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (02) :244-248
[32]   HALES,STEPHEN AND THE MEASUREMENT OF BLOOD-PRESSURE [J].
LEWIS, O .
JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (12) :865-871
[33]   Effect of positioning on blood pressure measurement in pregnancy [J].
Myers, Monica C. ;
Brandt, Debra S. ;
Prunty, April ;
Gilbertson-White, Stephanie ;
Sanborn, Amy ;
Santillan, Mark K. ;
Santillan, Donna A. .
PREGNANCY HYPERTENSION-AN INTERNATIONAL JOURNAL OF WOMENS CARDIOVASCULAR HEALTH, 2022, 27 :110-114
[34]   Blood pressure measurement using Korotkoff sounds [J].
Mahajan, Rutvij ;
Thakurdesai, Shantanu ;
Modak, Gaurav ;
Jotrao, Sumit ;
Bhat, Ajinkya .
2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, :635-639
[35]   The influence of cuff size on blood pressure measurement [J].
Bakx, C ;
Oerlemans, G ;
vandenHoogen, H ;
vanWeel, C ;
Thien, T .
JOURNAL OF HUMAN HYPERTENSION, 1997, 11 (07) :439-445
[36]   History of Blood Pressure Measurement in Newborns and Infants [J].
Javorka, Kamil .
PHYSIOLOGICAL RESEARCH, 2023, 72 (05) :543-555
[37]   The influence of cuff size on blood pressure measurement [J].
C Bakx ;
G Oerlemans ;
H van den Hoogen ;
C van Weel ;
T Thien .
Journal of Human Hypertension, 1997, 11 :439-445
[38]   Automated blood pressure measurement for diagnosing hypertension [J].
Myers, Martin G. .
BLOOD PRESSURE MONITORING, 2007, 12 (06) :405-406
[39]   Blood Pressure Measurement: Assessment of a Variable Quantity [J].
Jobbagy, Akos ;
Csordas, Peter ;
Mersich, Andras .
ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2011, 80 (04) :316-324
[40]   Personalization of the Oscillometric Blood-Pressure Measurement [J].
Nagy, P. ;
Jobbagy, A. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02) :885-888