An Implantable Microsystem for Tonometric Blood Pressure Measurement

被引:41
作者
Ziaie, Babak [1 ]
Najafi, Khalil [2 ,3 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Michigan, Dept Elect Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Comp Sci Ctr Integrated Microsyst, Ann Arbor, MI 48109 USA
基金
美国国家航空航天局;
关键词
implantable microsystems; tonometry; bioMEMS; biomedical microdevices; blood pressure measurement; biomedical transducers;
D O I
10.1023/A:1012452613720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable microsystem for tonometric blood pressure measurement in small animals. The microsystem consists of four major components: (1) a titanium base for supporting a pressure sensor and an interface chip, (2) a micromachined capacitive pressure sensor array, (3) a switched-capacitor interface chip, and (4) a titanium cap. A new micromachining fabrication process has been developed to create capacitive pressure transducers with a flat surface necessary for tonometric pressure measurement. An array of three capacitive sensors is used to increase signal output and improve stability. A custom-designed switched-capacitor CMOS interface circuit is used to measure changes in capacitance. In vitro calibration tests have been performed on the complete cuff using a silastic tube to mimic a pliable blood vessel. A sensitivity of 2 mV/mmHg @ 100 mmHg and a resolution of 0.5 mmHg (based on 1 mV RMS interface chip noise floor) has been obtained. The dimensions of the cuff system 10(L) x 6.5(W) x 3(11) mm(3).
引用
收藏
页码:285 / 292
页数:8
相关论文
共 50 条
[21]   Blood pressure measurement in children and adolescents [J].
Kardas, Przemyslaw .
FAMILY MEDICINE AND PRIMARY CARE REVIEW, 2008, 10 (02) :226-230
[22]   How to do Blood Pressure Measurement [J].
Middeke, Martin .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2016, 141 (12) :884-888
[23]   Narrowband auscultatory blood pressure measurement [J].
Sebald, DJ ;
Bahr, DE ;
Kahn, AR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) :1038-1044
[24]   Association of Heart Rate With Blood Pressure Variability: Implications for Blood Pressure Measurement [J].
Cahan, Amos ;
Ben-Dov, Iddo Z. ;
Bursztyn, Michael .
AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (03) :313-318
[25]   Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods [J].
Narita, Keisuke ;
Shimbo, Daichi ;
Kario, Kazuomi .
HYPERTENSION RESEARCH, 2024, 47 (12) :3345-3355
[26]   Recent advances in blood pressure measurement technology: normalized blood pressure measurement with a double-cuff sphygmotonometer [J].
Tochikubo, O ;
Kimura, K .
BLOOD PRESSURE MONITORING, 2001, 6 (06) :297-301
[27]   Actual Standard of Blood Pressure Measurement - Statement of the German High Blood Pressure League [J].
Eckert, Siegfried ;
Ott, Christian ;
Buechner, Nikolaus ;
Dechend, Ralf ;
Lueders, Stephan ;
Mengden, Thomas ;
Sanner, Bernd .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2019, 144 (21) :1522-1527
[28]   The impact of pulse pressure on the accuracy of wrist blood pressure measurement [J].
T H Westhoff ;
S Schmidt ;
R Meissner ;
W Zidek ;
M van der Giet .
Journal of Human Hypertension, 2009, 23 :391-395
[29]   The impact of pulse pressure on the accuracy of wrist blood pressure measurement [J].
Westhoff, T. H. ;
Schmidt, S. ;
Meissner, R. ;
Zidek, W. ;
van der Giet, M. .
JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (06) :391-395
[30]   The Enigma of Blood Pressure Measurement in Children with CKD [J].
Falkner, Bonita .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2018, 13 (03) :359-360