An Implantable Microsystem for Tonometric Blood Pressure Measurement

被引:41
|
作者
Ziaie, Babak [1 ]
Najafi, Khalil [2 ,3 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Michigan, Dept Elect Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Comp Sci Ctr Integrated Microsyst, Ann Arbor, MI 48109 USA
基金
美国国家航空航天局;
关键词
implantable microsystems; tonometry; bioMEMS; biomedical microdevices; blood pressure measurement; biomedical transducers;
D O I
10.1023/A:1012452613720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an implantable microsystem for tonometric blood pressure measurement in small animals. The microsystem consists of four major components: (1) a titanium base for supporting a pressure sensor and an interface chip, (2) a micromachined capacitive pressure sensor array, (3) a switched-capacitor interface chip, and (4) a titanium cap. A new micromachining fabrication process has been developed to create capacitive pressure transducers with a flat surface necessary for tonometric pressure measurement. An array of three capacitive sensors is used to increase signal output and improve stability. A custom-designed switched-capacitor CMOS interface circuit is used to measure changes in capacitance. In vitro calibration tests have been performed on the complete cuff using a silastic tube to mimic a pliable blood vessel. A sensitivity of 2 mV/mmHg @ 100 mmHg and a resolution of 0.5 mmHg (based on 1 mV RMS interface chip noise floor) has been obtained. The dimensions of the cuff system 10(L) x 6.5(W) x 3(11) mm(3).
引用
收藏
页码:285 / 292
页数:8
相关论文
共 50 条
  • [1] An Implantable Microsystem for Tonometric Blood Pressure Measurement
    Babak Ziaie
    Khalil Najafi
    Biomedical Microdevices, 2001, 3 : 285 - 292
  • [2] A FEW DETAILS REGARDING TONOMETRIC MEASUREMENT OF BLOOD-PRESSURE
    BRUNER, JMR
    ANESTHESIOLOGY, 1992, 77 (02) : 396 - 397
  • [3] A FEW DETAILS REGARDING TONOMETRIC MEASUREMENT OF BLOOD-PRESSURE - REPLY
    KEMMOTSU, O
    ECKERLE, JS
    ANESTHESIOLOGY, 1992, 77 (02) : 397 - 398
  • [4] Wireless Batteryless Implantable Blood Pressure Monitoring Microsystem for Small Laboratory Animals
    Cong, Peng
    Ko, Wen H.
    Young, Darrin J.
    IEEE SENSORS JOURNAL, 2010, 10 (02) : 243 - 254
  • [5] Comparison of blood pressure measurement consistency using tonometric and automated oscillometric instruments
    Yucha, CB
    Calderon, KS
    Tsai, PS
    Yang, MCK
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2002, 27 (04) : 306 - 306
  • [6] Wireless Implantable Blood Pressure Sensing Microsystem Design for Monitoring of Small Laboratory Animals
    Cong, Peng
    Ko, Wen H.
    Young, Darrin J.
    SENSORS AND MATERIALS, 2008, 20 (07) : 327 - 340
  • [7] Integrated Electronic System Design for an Implantable Wireless Batteryless Blood Pressure Sensing Microsystem
    Cong, Peng
    Ko, Wen H.
    Young, Darrin J.
    IEEE COMMUNICATIONS MAGAZINE, 2010, 48 (04) : 98 - 104
  • [8] Use of radial arterial tonometric continuous blood pressure measurement in cardiovascular reactivity studies
    Nelesen, RA
    Dimsdale, JE
    BLOOD PRESSURE MONITORING, 2002, 7 (05) : 259 - 263
  • [9] Subcubic Millimeter Wireless Implantable Intraocular Pressure Monitor Microsystem
    Bhamra, Hansraj
    Tsai, Jui-Wei
    Huang, Yu-Wen
    Yuan, Quan
    Shah, Jay V.
    Irazoqui, Pedro
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) : 1204 - 1215
  • [10] A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
    Ahmadi, Mohammad Mahdi
    Jullien, Graham A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (03) : 169 - 180