Invasive Device-Related Nosocomial Infection Surveillance in Intensive Care Unit

被引:4
作者
Cukurova, Zafer [1 ]
Durdu, Bulent [2 ]
Hergunsel, Oya [1 ]
Eren, Gulay [1 ]
Tekdos, Yasemin [1 ]
Durdu, Yasemin [3 ]
机构
[1] Bakirkoy Dr Sadi Konuk Egitim & Arastirma Hastane, Anestezi & Reanimasyon Klin, Istanbul, Turkey
[2] Bakirkoy Dr Sadi Konuk Egitim & Arastirma Hastane, Enfeksiyon Hastaliklari & Klin Mikrobiyol Birimi, Istanbul, Turkey
[3] Esenyurt Devlet Hastanesi, Enfeksiyon Hastaliklari & Klin Mikrobiyol Birimi, Istanbul, Turkey
来源
TURKIYE KLINIKLERI TIP BILIMLERI DERGISI | 2012年 / 32卷 / 02期
关键词
Catheter-related infections; urinary catheterization; urinary tract infections; RATES;
D O I
10.5336/medsci.2011-24387
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study is to determine invasive device-related nosocomial infection (IDRNI) rates of our hospital and to determine new strategies by reviewing infection control measures and to improve the quality of patient care and treatment. Material and Methods: Our study was carried out as an active, prospective, patient and laboratory based surveillance study by recording daily data of 1567 patients who had been monitored longer than 48 hours in Anesthesiology and Reanimation Clinic of Bakirkoy Dr. Sadi Konuk Training and Research Hospital between January 2008-January 2011. Estimations and diagnosis were done according to Center for Disease Control and prevention-CDC criteria. Results: A total of 252 invasive device-related nosocomial infections were detected in 12.981 patient days of 1567 patients during three years, between January 2008 and January 2011. Ventilator-related pneumonia rates was detected as 12.60, 16.87 and 16.21, respectively in 1000 ventilator days according to years. Central catheter-related bloodstream infection rate was found as 12.36, 9.53 and 6.44, respectively in 1000 catheter days according to years. Catheter-related urinary system infection rates were found as 5.09, 5.76 and 1.81 in 1000, respectively urinary catheter days according to years. The most common pathogen isolated from invasive device-related nosocomial infection in three years was Acinetobacter spp. (24.2%) followed by coagulase negative staphylococcus (11.4%), Pseudomonas aeruginosa (11.4%), Escherichia coli (11%) and Staphylococcus aureus (10.6%). Conclusion: IDRNI rates in our clinic are consistent with data reported from Turkey. Our main aim will be to reduce these rates by increasing effective protection methods.
引用
收藏
页码:438 / 443
页数:6
相关论文
共 50 条
  • [21] Catheter-associated urinary tract infection in a surgical intensive care unit
    Mladenovic, Jovan
    Veljovic, Milic
    Udovicic, Ivo
    Lazic, Srdjan
    Jadranin, Zeljko
    Segrt, Zoran
    Ristic, Petar
    Suljagic, Vesna
    VOJNOSANITETSKI PREGLED, 2015, 72 (10) : 883 - 888
  • [22] Surveillance of device-associated infections in intensive care units of a tertiary care hospital
    Rizwan, M.
    Ikram, A.
    Zaman, G.
    Satti, L.
    Ahmed, P.
    JOURNAL OF HOSPITAL INFECTION, 2017, 95 (01) : 101 - 102
  • [23] Preventing infection in the intensive care unit: Targeted or universal decolonization
    Peter, John Victor
    NATIONAL MEDICAL JOURNAL OF INDIA, 2013, 26 (03) : 161 - 163
  • [24] Infection Acquisition Following Intensive Care Unit Room Privatization
    Teltsch, Dana Y.
    Hanley, James
    Loo, Vivian
    Goldberg, Peter
    Gursahaney, Ash
    Buckeridge, David L.
    ARCHIVES OF INTERNAL MEDICINE, 2011, 171 (01) : 32 - 38
  • [25] Prevention and management catheter-associated urinary tract infection in intensive care unit
    Rahimi, Mehdi
    Farhadi, Khosro
    Babaei, Hossein
    Soleymani, Firouz
    JOURNAL OF NURSING AND MIDWIFERY SCIENCES, 2019, 6 (02) : 98 - 103
  • [26] Device-associated hospital-acquired infection rates in Turkish intensive care units.: Findings of the International Nosocomial Infection Control Consortium (INICC)
    Leblebicioglu, H.
    Rosenthal, V. D.
    Arikan, O. A.
    Ozgultekin, A.
    Yalcin, A. N.
    Koksal, I.
    Usluer, G.
    Sardan, Y. C.
    Ulusoy, S.
    JOURNAL OF HOSPITAL INFECTION, 2007, 65 (03) : 251 - 257
  • [27] Device-related infection in de novo transvenous implantable cardioverter-defibrillator Medicare patients
    El-Chami, Mikhael F.
    Jacobsen, Caroline M.
    Griffiths, Robert, I
    Hansen, Linda K.
    Wold, Nick
    Amorosi, Stacey L.
    Stivland, Timothy M.
    Knight, Bradley P.
    Weiss, Raul
    Mark, George E.
    Biffi, Mauro
    Probst, Vincent
    Lambiase, Pier D.
    Miller, Marc A.
    Baddour, Larry M.
    HEART RHYTHM, 2021, 18 (08) : 1301 - 1309
  • [28] Bundled preparation of skin antisepsis decreases the risk of cardiac implantable electronic device-related infection
    Chen, Huang-Chung
    Chen, Mien-Cheng
    Chen, Yung-Lung
    Tsai, Tzu-Hsien
    Pan, Kuo-Li
    Lin, Yu-Sheng
    EUROPACE, 2016, 18 (06): : 858 - 867
  • [29] Epidemiology of device-associated infections in an intensive care unit of a teaching hospital in Nepal: A prospective surveillance study from a developing country
    Parajuli, Narayan Prasad
    Acharya, Subhash Prasad
    Dahal, Santosh
    Singh, Jaya Prasad
    Mishra, Shyam Kumar
    Kattel, Hari Prasad
    Rijal, Basista Prasad
    Pokhrel, Bharat Mani
    AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (09) : 1024 - 1029
  • [30] ISCCM Position Statement on the Management of Invasive Fungal Infections in the Intensive Care Unit
    Bhattacharya, Pradip Kumar
    Chakrabarti, Arunaloke
    Sinha, Saswati
    Pande, Rajesh
    Gupta, Sachin
    Kumar, A. K. Ajith
    Mishra, Vijay Kumar
    Kumar, Sanjeev
    Bhosale, Shilpushp
    Reddy, Pavan Kumar
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2024, 28 (SUPPL) : S20 - S41