Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes

被引:32
作者
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
Cervino, Alejandro [1 ]
Alfonso, Jose F. [2 ,3 ]
Fernandez-Vega, Luis [2 ,3 ]
机构
[1] Univ Valencia, Fac Phys, Dept Opt, Optometry Res Grp, E-46100 Burjassot, Spain
[2] Univ Oviedo, Fernandez Vega Ophthalmol Inst, Sch Med, Oviedo, Spain
[3] Univ Oviedo, Dept Surg, Sch Med, Oviedo, Spain
关键词
D O I
10.1016/j.jcrs.2008.06.046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate distance and near contrast sensitivity under photopic and mesopic conditions before and after refractive lens exchange (RLE) with implantation of a diffractive multifocal intraocular lens (IOL). SETTING: University of Valencia, Valencia, Spain, METHODS: Monocular contrast sensitivity function was measured with the Functional Acuity Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m(2), 5.0 cd/m(2), and 2.5 cd/m(2)) before and after FILE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (<= 1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter +/- 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistically significant differences between preoperative and postoperative results at any distance or spatial frequency or under any lighting condition (P >.1, t test). CONCLUSIONS: Refractive lens exchange with implantation of a diffractive multifocal IOL gave good distance and near contrast sensitivity under photopic and mesopic conditions. Although mesopic contrast sensitivity was reduced at distance and near compared to that under photopic conditions, the performance was comparable to that with the natural lens preoperatively.
引用
收藏
页码:2043 / 2048
页数:6
相关论文
共 19 条
[1]   Prospective study of the Acri.LISA bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Senaris, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1930-1935
[2]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[3]   Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :430-438
[4]   Retinal straylight in patients with monofocal and multifocal intraocular lenses [J].
Cervino, Alejandro ;
Hosking, Sarah L. ;
Montes-Mico, Robert ;
Alio, Jorge L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :441-446
[5]   Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intralocular lenses [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :280-286
[6]   ReSTOR intraocular lens implantation in cataract surgery: Quality of vision [J].
Chiam, Patrick J. T. ;
Chan, Jin H. ;
Aggarwal, Rajesh K. ;
Kasaby, Sam .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1459-1463
[7]   History and development of the apodized diffractive intraocular lens [J].
Davison, James A. ;
Simpson, Michael J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :849-858
[8]   Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens [J].
Fernandez-Vega, Luis ;
Alfonso, Jose F. ;
Montes-Mico, Robert ;
Amhaz, Hussein .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (02) :199-204
[9]   Clear lens extraction with multifocal apodized diffractive intraocular lens implantation [J].
Fernandez-Vega, Luis ;
Alfonso, Jose F. ;
Rodriguez, Pedro P. ;
Montes-Mico, Robert .
OPHTHALMOLOGY, 2007, 114 (08) :1491-1498
[10]   European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens [J].
Kohnen, T ;
Allen, D ;
Boureau, C ;
Dublineau, P ;
Hartmann, C ;
Mehdorn, E ;
Rozot, P ;
Tassinari, G .
OPHTHALMOLOGY, 2006, 113 (04) :578-584