In-Vivo Microsystems: A Review

被引:6
作者
French, Paddy [1 ]
机构
[1] Delft Univ Technol, Lab Bioelect, Fac Elect Engn Math & Comp Sci, Mekelweg 4, NL-2628 CD Delft, Netherlands
关键词
medical sensors; implants; in-vivo devices; microsystems; GLUCOSE SENSOR; IMPLANT; SYSTEM; PACEMAKER;
D O I
10.3390/s20174953
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In-vivosensors yield valuable medical information by measuring directly on the living tissue of a patient. These devices can be surface or implant devices. Electrical activity in the body, from organs or muscles can be measured using surface electrodes. For short term internal devices, catheters are used. These include cardiac catheter (in blood vessels) and bladder catheters. Due to the size and shape of the catheters, silicon devices provided an excellent solution for sensors. Since many cardiac catheters are disposable, the high volume has led to lower prices of the silicon sensors. Many catheters use a single sensor, but silicon offers the opportunity to have multi sensors in a single catheter, while maintaining small size. The cardiac catheter is usually inserted for a maximum of 72 h. Some devices may be used for a short-to-medium period to monitor parameters after an operation or injury (1-4 weeks). Increasingly, sensing, and actuating, devices are being applied to longer term implants for monitoring a range of parameters for chronic conditions. Devices for longer term implantation presented additional challenges due to the harshness of the environment and the stricter regulations for biocompatibility and safety. This paper will examine the three main areas of application for in-vivo devices: surface devices and short/medium-term and long-term implants. The issues of biocompatibility and safety will be discussed.
引用
收藏
页码:1 / 22
页数:24
相关论文
共 50 条
  • [31] In-Vitro and In-Vivo Study of Indomethacin Loaded Gelatin Nanoparticles
    Kumar, Rakesh
    Nagarwal, Ramesh C.
    Dhanawat, Meenakshi
    Pandit, Jayanta Kumar
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2011, 7 (03) : 325 - 333
  • [32] A sub-cm3 energy harvester for in-vivo biosensors
    Baelhadj, Hacene C.
    Adhikari, Shyam S.
    Davoodi, Hossein
    Badilita, Vlad
    Beyaz, Mustafa Ilker
    MICROELECTRONIC ENGINEERING, 2020, 226
  • [33] Formulation and Characterization of Carvedilol Leciplex for Glaucoma Treatment: In-Vitro, Ex-Vivo and In-Vivo Study
    Hassan, Doaa H.
    Abdelmonem, Rehab
    Abdellatif, Menna M.
    PHARMACEUTICS, 2018, 10 (04):
  • [34] Barrier Properties of Polymer Encapsulation Materials for Implantable Microsystems
    Kirsten, Sabine
    Wetterling, Jakob
    Uhlemann, Juergen
    Wolter, Klaus-Juergen
    Zigler, Sergej
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 269 - 272
  • [35] Design of MEMS and microsystems
    Nagel, DJ
    DESIGN, TEST, AND MICROFABRICATION OF MEMS AND MOEMS, PTS 1 AND 2, 1999, 3680 : 20 - 29
  • [36] Integrated sensors and microsystems
    Ramirez-Fernandez, F. J.
    Salcedo, W. J.
    Peixoto, N.
    REVISTA MEXICANA DE FISICA, 2006, 52 (02) : 104 - 107
  • [37] Future of actuators and microsystems
    Fujita, H
    SENSORS AND ACTUATORS A-PHYSICAL, 1996, 56 (1-2) : 105 - 111
  • [38] Microfabrication technologies for microsystems
    deRooij, NF
    MICROMACHINING AND MICROFABRICATION PROCESS TECHNOLOGY III, 1997, 3223 : 2 - 9
  • [39] Materials and processes for microsystems
    Nagel, DJ
    SURFACE & COATINGS TECHNOLOGY, 1998, 104 : 138 - 145
  • [40] Ferroelectrics, microsystems and nanotechnology
    Whatmore, RW
    FERROELECTRICS, 1999, 225 (1-4) : 985 - 998