In-Vivo Microsystems: A Review

被引:6
作者
French, Paddy [1 ]
机构
[1] Delft Univ Technol, Lab Bioelect, Fac Elect Engn Math & Comp Sci, Mekelweg 4, NL-2628 CD Delft, Netherlands
关键词
medical sensors; implants; in-vivo devices; microsystems; GLUCOSE SENSOR; IMPLANT; SYSTEM; PACEMAKER;
D O I
10.3390/s20174953
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In-vivosensors yield valuable medical information by measuring directly on the living tissue of a patient. These devices can be surface or implant devices. Electrical activity in the body, from organs or muscles can be measured using surface electrodes. For short term internal devices, catheters are used. These include cardiac catheter (in blood vessels) and bladder catheters. Due to the size and shape of the catheters, silicon devices provided an excellent solution for sensors. Since many cardiac catheters are disposable, the high volume has led to lower prices of the silicon sensors. Many catheters use a single sensor, but silicon offers the opportunity to have multi sensors in a single catheter, while maintaining small size. The cardiac catheter is usually inserted for a maximum of 72 h. Some devices may be used for a short-to-medium period to monitor parameters after an operation or injury (1-4 weeks). Increasingly, sensing, and actuating, devices are being applied to longer term implants for monitoring a range of parameters for chronic conditions. Devices for longer term implantation presented additional challenges due to the harshness of the environment and the stricter regulations for biocompatibility and safety. This paper will examine the three main areas of application for in-vivo devices: surface devices and short/medium-term and long-term implants. The issues of biocompatibility and safety will be discussed.
引用
收藏
页码:1 / 22
页数:24
相关论文
共 50 条
  • [21] Microsystems in medicine
    Wallrabe, U
    Ruther, P
    Schaller, T
    Schomburg, WK
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03) : 137 - 146
  • [22] Microsystems and mechanics
    Corigliano, Alberto
    Ardito, Raffaele
    Comi, Claudia
    Frangi, Attilio
    Ghisi, Aldo
    Mariani, Stefano
    MECHANICS FOR THE WORLD: PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF THEORETICAL AND APPLIED MECHANICS, ICTAM2012, 2014, 10 : 138 - 160
  • [23] Electrochemistry and microsystems
    Ehrfeld, W
    ELECTROCHIMICA ACTA, 2003, 48 (20-22) : 2857 - 2868
  • [24] Micromachining of alumina ceramic for microsystems applications: a systematic review, challenges and future opportunities
    Shanu, Anurag
    Sharma, Priyaranjan
    Dixit, Pradeep
    MATERIALS AND MANUFACTURING PROCESSES, 2024, 39 (07) : 892 - 924
  • [25] Developing robust vision modules for microsystems applications
    Bilen, Hakan
    Hocaoglu, Muhammet A.
    Unel, Mustafa
    Sabanovic, Asif
    MACHINE VISION AND APPLICATIONS, 2012, 23 (01) : 25 - 42
  • [26] Review of the potential of a wireless MEMS and TFT microsystems for the measurement of pressure in the GI tract
    Arshak, A
    Arshak, K
    Waldron, D
    Morris, D
    Korostynska, O
    Jafer, E
    Lyons, G
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) : 347 - 356
  • [27] THE IN-VIVO HISTOLOGY OF AN ABSORBABLE SUTURE ANCHOR - A PRELIMINARY-REPORT
    BARBER, FA
    DECK, MA
    ARTHROSCOPY, 1995, 11 (01): : 77 - 81
  • [28] ELECTROCATALYTIC GLUCOSE SENSOR FOR LONG-TERM IN-VIVO USE
    LAGER, W
    VONLUCADOU, I
    NISCHIK, H
    NOWAK, T
    PREIDEL, W
    RUPRECHT, L
    STANZEL, MJ
    TEGEDER, V
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (03) : 183 - 188
  • [29] An in-vivo method for biomechanical characterization of bone-anchored implants
    Brånemark, R
    Skalak, R
    MEDICAL ENGINEERING & PHYSICS, 1998, 20 (03) : 216 - 219
  • [30] In-vivo bioavailability and lymphatic uptake evaluation of lipid nanoparticulates of darunavir
    Bhalekar, Mangesh R.
    Upadhaya, Prashant G.
    Madgulkar, Ashwini R.
    Kshirsagar, Sanjay J.
    Dube, Akanksha
    Bartakke, Utkarsh S.
    DRUG DELIVERY, 2016, 23 (07) : 2581 - 2586