Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT

被引:97
作者
Kurz, Christopher [1 ,2 ]
Kamp, Florian [1 ]
Park, Yang-Kyun [3 ,4 ]
Zoellner, Christoph [2 ]
Rit, Simon [5 ]
Hansen, David [6 ]
Podesta, Mark [7 ]
Sharp, Gregory C. [3 ,4 ]
Li, Minglun [1 ]
Reiner, Michael [1 ]
Hofmaier, Jan [1 ]
Neppl, Sebastian [1 ]
Thieke, Christian [1 ]
Nijhuis, Reinoud [1 ]
Ganswindt, Ute [1 ]
Belka, Claus [1 ]
Winey, Brian A. [3 ,4 ]
Parodi, Katia [2 ]
Landry, Guillaume [2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Radiat Oncol, D-81377 Munich, Germany
[2] Univ Munich, Dept Med Phys, D-85748 Garching, Germany
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Harvard Med Sch, Boston, MA 02114 USA
[5] Univ Lyon 1, INSA Lyon, CNRS Inserm U1044 UMR5220m, CREATIS, F-69373 Lyon, France
[6] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[7] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, NL-6229 ET Maastricht, Netherlands
关键词
proton therapy; cone-beam CT; adaptive radiotherapy; CONE-BEAM CT; INTENSITY-MODULATED RADIOTHERAPY; PROTON THERAPY; COMPUTED-TOMOGRAPHY; PROSTATE-CANCER; RADIATION-THERAPY; NECK-CANCER; HEAD; RECALCULATION; MOTION;
D O I
10.1118/1.4962933
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work aims at investigating intensity corrected cone-beam x-ray computed tomography (CBCT) images for accurate dose calculation in adaptive intensity modulated proton therapy (IMPT) for prostate and head and neck (H&N) cancer. A deformable image registration (DIR)-based method and a scatter correction approach using the image data obtained from DIR as prior are characterized and compared on the basis of the same clinical patient cohort for the first time. Methods: Planning CT (pCT) and daily CBCT data (reconstructed images and measured projections) of four H&N and four prostate cancer patients have been considered in this study. A previously validated Morphons algorithm was used for DIR of the planning CT to the current CBCT image, yielding a so-called virtual CT (vCT). For the first time, this approach was translated from H&N to prostate cancer cases in the scope of proton therapy. The warped pCT images were also used as prior for scatter correction of the CBCT projections for both tumor sites. Single field uniform dose and IMPT (only for H&N cases) treatment plans have been generated with a research version of a commercial planning system. Dose calculations on vCT and scatter corrected CBCT (CBCTcor) were compared by means of the proton range and a gamma-index analysis. For the H&N cases, an additional diagnostic replanning CT (rpCT) acquired within three days of the CBCT served as additional reference. For the prostate patients, a comprehensive contour comparison of CBCT and vCT, using a trained physician's delineation, was performed. Results: A high agreement of vCT and CBCTcor was found in terms of the proton range and gamma-index analysis. For all patients and indications between 95% and 100% of the proton dose profiles in beam's eye view showed a range agreement of better than 3 mm. The pass rate in a (2%, 2 mm) gamma-comparison was between 96% and 100%. For H&N patients, an equivalent agreement of vCT and CBCTcor to the reference rpCT was observed. However, for the prostate cases, an insufficient accuracy of the vCT contours retrieved from DIR was found, while the CBCTcor contours showed very high agreement to the contours delineated on the raw CBCT. Conclusions: For H&N patients, no considerable differences of vCT and CBCTcor were found. For prostate cases, despite the high dosimetric agreement, the DIR yields incorrect contours, probably due to the more pronounced anatomical changes in the abdomen and the reduced soft-tissue contrast in the CBCT. Using the vCT as prior, these inaccuracies can be overcome and images suitable for accurate delineation and dose calculation in CBCT-based adaptive IMPT can be retrieved from scatter correction of the CBCT projections. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:5635 / 5646
页数:12
相关论文
共 37 条
[1]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[2]   Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods [J].
Beltran, Chris. ;
Herman, Michael G. ;
Davis, Brian J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :289-295
[3]   Motion in radiotherapy: particle therapy [J].
Bert, C. ;
Durante, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :R113-R114
[4]   Analysis of interfraction prostate motion using megavoltage cone beam computed tomography [J].
Bylund, Kevin C. ;
Bayouth, John E. ;
Smith, Mark C. ;
Hass, A. Curtis ;
Bhatia, Sudershan K. ;
Buatti, John M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (03) :949-956
[5]   A study on adaptive IMRT treatment planning using kV cone-beam CT [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Deeley, Matthew ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) :116-125
[6]   Charged particles in radiation oncology [J].
Durante, Marco ;
Loeffler, Jay S. .
NATURE REVIEWS CLINICAL ONCOLOGY, 2010, 7 (01) :37-43
[7]   ART for head and neck patients: On the difference between VMAT and IMPT [J].
Gora, Joanna ;
Kuess, Peter ;
Stock, Markus ;
Andrzejewski, Piotr ;
Knaeusl, Barbara ;
Paskeviciute, Brigita ;
Altorjai, Gabriela ;
Georg, Dietmar .
ACTA ONCOLOGICA, 2015, 54 (08) :1166-1174
[8]   Implementation and evaluation of various demons deformable image registration algorithms on a GPU [J].
Gu, Xuejun ;
Pan, Hubert ;
Liang, Yun ;
Castillo, Richard ;
Yang, Deshan ;
Choi, Dongju ;
Castillo, Edward ;
Majumdar, Amitava ;
Guerrero, Thomas ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :207-219
[9]   Prospective longitudinal assessment of parotid gland function using dynamic quantitative pertechnate scintigraphy and estimation of dose-response relationship of parotid-sparing radiotherapy in head-neck cancers [J].
Gupta, Tejpal ;
Hotwani, Chandni ;
Kannan, Sadhana ;
Master, Zubin ;
Rangarajan, Venkatesh ;
Murthy, Vedang ;
Budrukkar, Ashwini ;
Ghosh-Laskar, Sarbani ;
Agarwal, Jai Prakash .
RADIATION ONCOLOGY, 2015, 10
[10]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .