A Novel Robotic-Assisted Technique to Implant the Responsive Neurostimulation System

被引:9
作者
Tran, Diem Kieu [1 ]
Paff, Michelle [1 ]
Mnatsakanyan, Lilit [2 ]
Sen-Gupta, Indranil [2 ]
Lin, Jack J. [2 ]
Hsu, Frank P. K. [1 ]
Vadera, Sumeet [1 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Neurol Surg, 200 S Manchester,Suite 210, Orange, CA 92668 USA
[2] Univ Calif Irvine, Sch Med, Dept Neurol, Orange, CA 92668 USA
关键词
ECoG; Epilepsy; Refractory; RNS; Robotic; sEEG; Stereotactic; BRAIN-STIMULATION; ACCURACY; PLACEMENT; EPILEPSY; METHODOLOGY; SAFETY; ADULTS;
D O I
10.1093/ons/opz226
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The responsive neurostimulation system (RNS) (NeuroPace Inc, Mountain View, California) was approved as an adjunctive therapy for medically refractory focal epilepsy. RNS detects epileptiform patterns and delivers electrical stimulation to abort seizures. OBJECTIVE: To describe a novel technique of RNS lead implantation using robotic-assisted targeting of ictal-onset zones based on stereoelectroencephalography (sEEG) localization. Secondary objectives are to report the accuracy of robotic-assisted lead implantation using the ROSA robot as well as to report the clinical outcome achieved after RNS implantation by this method. METHODS: A total of 16 patients with medically refractory focal epilepsy underwent sEEG implantation for ictal-onset localization followed by robotic RNS implantation. The electrode most correlative with ictal onset on sEEG was chosen as the target for the RNS electrode. Seizure control wasmeasured at 6-mo and 1-yr follow-up. Ictal-onset electrocorticography (ECoG) data from RNS were compared with ictal onset from sEEG leads based on calculations of lead target to actual lead location from the ROSA robot. RESULTS: At 6-mo follow-up, the average percent seizure reduction was 82% based upon self-reported seizure diaries. At 1-yr follow-up, 8 patients had an average of 90% seizure reduction. The location of seizure onset from ECoG data showsimilar onset fromsEEG leads within 0.165-mm discrepancy. CONCLUSION: The ROSA robot provides an ideal method for targeting subcortical ictalonset zones. This method of RNS lead implantation achieves high accuracy and is associated with favorable clinical outcomes.
引用
收藏
页码:728 / 735
页数:8
相关论文
共 50 条
[41]   Robotic-Assisted Percutaneous Coronary Intervention [J].
Lo N. ;
Gutierrez J.A. ;
Swaminathan R.V. .
Current Treatment Options in Cardiovascular Medicine, 2018, 20 (2)
[42]   Robotic-Assisted Salvage Supraglottic Laryngectomy [J].
Perez-Mitchell, Carlos ;
Acosta, Jaime A. ;
Ferrer-Torres, Luis E. .
PUERTO RICO HEALTH SCIENCES JOURNAL, 2014, 33 (02) :88-90
[43]   Robotic-assisted percutaneous coronary intervention [J].
Mangels, Daniel R. ;
Giri, Jay ;
Hirshfeld, John ;
Wilensky, Robert L. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (06) :948-955
[44]   Safety and Efficacy of Robotic-Assisted PCI [J].
Pancholy, Samir B. ;
Shah, Sanjay C. ;
Patel, Tejas M. .
CURRENT CARDIOLOGY REPORTS, 2022, 24 (07) :817-821
[45]   Results of using robotic-assisted navigational system in pedicle screw placement [J].
Chen, Hsuan-Yu ;
Xiao, Xiu-Yun ;
Chen, Chih-Wei ;
Chou, Hao-Kai ;
Sung, Chen-Yu ;
Lin, Feng-Huei ;
Chen, Po-Quang ;
Wong, Tze-Hong .
PLOS ONE, 2019, 14 (08)
[46]   Impact of Obesity on Robotic-Assisted Sacrocolpopexy [J].
Kissane, Lindsay M. ;
Calixte, Rose ;
Grigorescu, Bogdan ;
Finamore, Peter ;
Vintzileos, Anthony .
JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2017, 24 (01) :36-40
[47]   Robotic-assisted laparoscopic radical cystoprostatectomy [J].
Pruthi, Raj S. ;
Wallen, Eric M. .
EUROPEAN UROLOGY, 2008, 53 (02) :310-322
[48]   Frameless Robotic-Assisted Deep Brain Stimulation With the Mazor Renaissance System [J].
Liang, Allison S. ;
Ginalis, Elizabeth E. ;
Jani, Raja ;
Hargreaves, Eric L. ;
Danish, Shabbar F. .
OPERATIVE NEUROSURGERY, 2022, 22 (03) :158-164
[49]   Robotic-assisted excision of left para-aortic paraganglioma: a novel approach [J].
Tan, Jack Kang ;
Ramsingh, Jason .
JOURNAL OF SURGICAL CASE REPORTS, 2025, 2025 (01)
[50]   Clinical evaluation of autonomous robotic-assisted full-arch implant surgery: A 1-year prospective clinical study [J].
Xie, Rui ;
Liu, Yuchen ;
Wei, Hongbo ;
Zhang, Tingmin ;
Bai, Shizhu ;
Zhao, Yimin .
CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (04) :443-453