A Novel Robotic-Assisted Technique to Implant the Responsive Neurostimulation System

被引:9
|
作者
Tran, Diem Kieu [1 ]
Paff, Michelle [1 ]
Mnatsakanyan, Lilit [2 ]
Sen-Gupta, Indranil [2 ]
Lin, Jack J. [2 ]
Hsu, Frank P. K. [1 ]
Vadera, Sumeet [1 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Neurol Surg, 200 S Manchester,Suite 210, Orange, CA 92668 USA
[2] Univ Calif Irvine, Sch Med, Dept Neurol, Orange, CA 92668 USA
关键词
ECoG; Epilepsy; Refractory; RNS; Robotic; sEEG; Stereotactic; BRAIN-STIMULATION; ACCURACY; PLACEMENT; EPILEPSY; METHODOLOGY; SAFETY; ADULTS;
D O I
10.1093/ons/opz226
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The responsive neurostimulation system (RNS) (NeuroPace Inc, Mountain View, California) was approved as an adjunctive therapy for medically refractory focal epilepsy. RNS detects epileptiform patterns and delivers electrical stimulation to abort seizures. OBJECTIVE: To describe a novel technique of RNS lead implantation using robotic-assisted targeting of ictal-onset zones based on stereoelectroencephalography (sEEG) localization. Secondary objectives are to report the accuracy of robotic-assisted lead implantation using the ROSA robot as well as to report the clinical outcome achieved after RNS implantation by this method. METHODS: A total of 16 patients with medically refractory focal epilepsy underwent sEEG implantation for ictal-onset localization followed by robotic RNS implantation. The electrode most correlative with ictal onset on sEEG was chosen as the target for the RNS electrode. Seizure control wasmeasured at 6-mo and 1-yr follow-up. Ictal-onset electrocorticography (ECoG) data from RNS were compared with ictal onset from sEEG leads based on calculations of lead target to actual lead location from the ROSA robot. RESULTS: At 6-mo follow-up, the average percent seizure reduction was 82% based upon self-reported seizure diaries. At 1-yr follow-up, 8 patients had an average of 90% seizure reduction. The location of seizure onset from ECoG data showsimilar onset fromsEEG leads within 0.165-mm discrepancy. CONCLUSION: The ROSA robot provides an ideal method for targeting subcortical ictalonset zones. This method of RNS lead implantation achieves high accuracy and is associated with favorable clinical outcomes.
引用
收藏
页码:728 / 735
页数:8
相关论文
共 50 条
  • [1] A novel handheld robotic-assisted system for unicompartmental knee arthroplasty: surgical technique and early survivorship
    Battenberg, Andrew K.
    Netravali, Nathan A.
    Lonner, Jess H.
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (01) : 55 - 60
  • [2] Robotic-assisted revision total knee arthroplasty: a novel surgical technique
    Ngim, Hui-Ling Joanne
    Van Bavel, Dirk
    De Steiger, Richard
    Tang, Andrew W. W.
    ARTHROPLASTY, 2023, 5 (01)
  • [3] Accuracy of a novel semi-autonomous robotic-assisted surgery system for single implant placement: A case series
    Ding, Yude
    Zheng, Yuxin
    Chen, Runzhi
    Cao, Ruijue
    Chen, Jianping
    Wang, Linhong
    Yang, Fan
    JOURNAL OF DENTISTRY, 2023, 139
  • [4] Robotic-assisted pulley technique for the ventral hernia
    James J. Butz
    Seth L. Newman
    Journal of Robotic Surgery, 2021, 15 : 717 - 721
  • [5] Robotic-assisted pulley technique for the ventral hernia
    Butz, James J.
    Newman, Seth L.
    JOURNAL OF ROBOTIC SURGERY, 2021, 15 (05) : 717 - 721
  • [6] Robotic-Assisted Endorectal Advancement Flap: A Novel Technique for Supralevator Fistula Repair
    Rojas, Maria A.
    Kamal, Tareq Q.
    Khan, Asfandyar
    Estrada, Joaquin J.
    Kaminski, Jan P.
    DISEASES OF THE COLON & RECTUM, 2021, 64 (04) : E65 - E66
  • [7] Implant Site Infection and Bone Flap Osteomyelitis Associated with the NeuroPace Responsive Neurostimulation System
    Wei, Zhikui
    Gordon, Chad R.
    Bergey, Gregory K.
    Sacks, Justin M.
    Anderson, William S.
    WORLD NEUROSURGERY, 2016, 88 : 687.e1 - 687.e6
  • [8] Brain-responsive neurostimulation for epilepsy (RNS® System)
    Skarpaas, Tara L.
    Jarosiewicz, Beata
    Morrell, Martha J.
    EPILEPSY RESEARCH, 2019, 153 : 68 - 70
  • [9] First-in-Human Evaluation of a Novel Robotic-Assisted Coronary Angioplasty System
    Granada, Juan F.
    Delgado, Juan A.
    Uribe, Maria Paola
    Fernandez, Andres
    Blanco, Guillermo
    Leon, Martin B.
    Weisz, Giora
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) : 460 - 465
  • [10] Robotic-Assisted Thymectomy
    Castle, Shannon L.
    Kernstine, Kemp H.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2008, 20 (04) : 326 - 331