Calculation of retinal image quality for polychromatic light

被引:75
作者
Ravikumar, Sowmya [1 ]
Thibos, Larry N. [1 ]
Bradley, Arthur [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1364/JOSAA.25.002395
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Although the retinal image is typically polychromatic, few studies have examined polychromatic image quality in the human eye. We begin with a conceptual framework including the formulation of a psychophysical linking hypothesis that underlies the utility of image quality metrics based on the polychromatic point-spread function. We then outline strategies for computing polychromatic point-spread functions of the eye when monochromatic aberrations are known for only a single wavelength. Implementation problems and solutions for this strategy are described. Polychromatic image quality is largely unaffected by wavelength-dependent diffraction and higher-order chromatic aberration. However, accuracy is found to depend critically upon spectral sampling. Using typical aberrations from the Indiana Aberration Study, we assessed through-focus image quality for model eyes with and without chromatic aberrations using a polychromatic metric called the visual Strehl ratio. In the presence of typical levels of monochromatic aberrations, the effect of longitudinal chromatic aberration is greatly reduced. The effect of typical levels of transverse chromatic aberration is virtually eliminated in the presence of longitudinal chromatic aberration and monochromatic aberrations. Clinical value and limitations of the method are discussed. (C) 2008 Optical Society of America
引用
收藏
页码:2395 / 2407
页数:13
相关论文
共 58 条
[1]  
[Anonymous], WAVEFRONT CUSTOMIZED
[2]   Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity [J].
Applegate, Raymond A. ;
Marsack, Jason D. ;
Thibos, Larry N. .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (09) :635-640
[3]   Subjective depth-of-focus of the eye [J].
Atchison, DA ;
Charman, WN ;
Woods, RL .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) :511-520
[4]   CALCULATION OF AXIAL POLYCHROMATIC OPTICAL TRANSFER FUNCTION [J].
BARNDEN, R .
OPTICA ACTA, 1974, 21 (12) :981-1003
[5]   EVALUATION OF SUBJECTIVE IMAGE QUALITY WITH THE SQUARE-ROOT INTEGRAL METHOD [J].
BARTEN, PGJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (10) :2024-2031
[6]   Wide-angle chromatic aberration corrector for the human eye [J].
Benny, Yael ;
Manzanera, Silvestre ;
Prieto, Pedro M. ;
Ribak, Erez N. ;
Artal, Pablo .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (06) :1538-1544
[7]  
BRINDLEY GS, 1970, PHYSL RETINA VISUAL, P315
[8]  
Campbell CE, 2004, J REFRACT SURG, V20, pS495
[9]   OPTICAL AND RETINAL FACTORS AFFECTING VISUAL RESOLUTION [J].
CAMPBELL, FW ;
GREEN, DG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (03) :576-+
[10]   EFFECT OF CHROMATIC ABERRATION ON VISUAL ACUITTY [J].
CAMPBELL, FW ;
GUBISCH, RW .
JOURNAL OF PHYSIOLOGY-LONDON, 1967, 192 (02) :345-&