Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest

被引:74
作者
Monsieurs, Koenraad G. [1 ,2 ]
De Regge, Melissa [3 ]
Vansteelandt, Kristof [4 ]
De Smet, Jeroen [5 ]
Annaert, Emmanuel [5 ]
Lemoyne, Sabine [5 ]
Kalmar, Alain F. [6 ]
Calle, Paul A. [2 ]
机构
[1] Univ Antwerp Hosp, Emergency Dept, B-2650 Edegem, Belgium
[2] Univ Ghent, Fac Med & Hlth Sci, B-9000 Ghent, Belgium
[3] Univ Ghent, Dept Management Innovat & Entrepreneurship, B-9000 Ghent, Belgium
[4] Katholieke Univ Leuven, Univ Psychiat Ctr, B-3070 Kortenberg, Belgium
[5] Ghent Univ Hosp, Emergency Dept, B-9000 Ghent, Belgium
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesia, NL-9700 RB Groningen, Netherlands
关键词
Cardiac arrest; Cardiopulmonary resuscitation (CPR); Chest compressions; Compression depth; Compression rate; Prehospital; BASIC LIFE-SUPPORT; RESUSCITATION-COUNCIL GUIDELINES; CARDIOPULMONARY-RESUSCITATION; SECTION; QUALITY; FEEDBACK; CPR; PERFORMANCE; GUIDANCE;
D O I
10.1016/j.resuscitation.2012.07.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and goal of study: The relationship between chest compression rate and compression depth is unknown. In order to characterise this relationship, we performed an observational study in prehospital cardiac arrest patients. We hypothesised that faster compressions are associated with decreased depth. Materials and methods: In patients undergoing prehospital cardiopulmonary resuscitation by health care professionals, chest compression rate and depth were recorded using an accelerometer (E-series monitor-defibrillator, Zoll, USA). Compression depth was compared for rates < 80/min, 80-120/min and > 120/min. A difference in compression depth >0.5 cm was considered clinically significant. Mixed models with repeated measurements of chest compression depth and rate (level 1) nested within patients (level 2) were used with compression rate as a continuous and as a categorical predictor of depth. Results are reported as means and standard error (SE). Results and discussion: One hundred and thirty-three consecutive patients were analysed (213,409 compressions). Of all compressions 2% were < 80/min, 62% between 80 and 120/min and 36% > 120/min, 36% were < 4 cm deep, 45% between 4 and 5 cm, 19% > 5 cm. In 77 out of 133 (58%) patients a statistically significant lower depth was observed for rates > 120/min compared to rates 80-120/min, in 40 out of 133 (30%) this difference was also clinically significant. The mixed models predicted that the deepest compression (4.5 cm) occurred at a rate of 86/min, with progressively lower compression depths at higher rates. Rates > 145/min would result in a depth < 4 cm. Predicted compression depth for rates 80-120/min was on average 4.5 cm (SE 0.06) compared to 4.1 cm (SE 0.06) for compressions > 120/min (mean difference 0.4 cm, P < 0.001). Age and sex of the patient had no additional effect on depth. Conclusions: This study showed an association between higher compression rates and lower compression depths. Avoiding excessive compression rates may lead to more compressions of sufficient depth. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1319 / 1323
页数:5
相关论文
共 20 条
  • [1] CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system
    Abella, Benjamin S.
    Edelson, Dana P.
    Kim, Salem
    Retzer, Elizabeth
    Myklebust, Helge
    Barry, Anne M.
    O'Hearn, Nicholas
    Hoek, Terry L. Vanden
    Becker, Lance B.
    [J]. RESUSCITATION, 2007, 73 (01) : 54 - 61
  • [2] Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
    Abella, BS
    Alvarado, JP
    Myklebust, H
    Edelson, DP
    Barry, A
    O'Hearn, N
    Vanden Hoek, TL
    Becker, LB
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03): : 305 - 310
  • [3] Brown H, 2015, Applied mixed models in medicine
  • [4] A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation
    Chung, Tae Nyoung
    Kim, Sun Wook
    You, Je Sung
    Cho, Young Soon
    Chung, Sung Phil
    Park, Incheol
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (01) : 226 - 230
  • [5] Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
    Edelson, Dana P.
    Abella, Benjamin S.
    Kramer-Johansen, Jo
    Wik, Lars
    Myklebust, Helge
    Barry, Anne M.
    Merchant, Raina M.
    Vanden Hoek, Terry L.
    Steen, Petter A.
    Becker, Lance B.
    [J]. RESUSCITATION, 2006, 71 (02) : 137 - 145
  • [6] Field RA, 2011, RESUSCITATION
  • [7] Move over ANOVA - Progress in analyzing repeated-measures data and its reflection in papers published in the archives of general psychiatry
    Gueorguieva, R
    Krystal, JH
    [J]. ARCHIVES OF GENERAL PSYCHIATRY, 2004, 61 (03) : 310 - 317
  • [8] European Resuscitation Council Guidelines for Resuscitation 2005 - Section 2. Adult basic life support and use of automated external defibrillators
    Handley, AJ
    Koster, R
    Monsieurs, K
    Perkins, GD
    Davies, S
    Bossaert, L
    [J]. RESUSCITATION, 2005, 67 : S7 - S23
  • [9] Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial
    Hostler, David
    Everson-Stewart, Siobhan
    Rea, Thomas D.
    Stiell, Ian G.
    Callaway, Clifton W.
    Kudenchuk, Peter J.
    Sears, Gena K.
    Emerson, Scott S.
    Nichol, Graham
    [J]. BRITISH MEDICAL JOURNAL, 2011, 342 : 371
  • [10] Influence of chest compression rate guidance on the quality of cardiopulmonary resuscitation performed on manikins
    Jantti, H.
    Silfvast, T.
    Turpeinen, A.
    Kiviniemi, V.
    Uusaro, A.
    [J]. RESUSCITATION, 2009, 80 (04) : 453 - 457