A Decision-Making Algorithm for Concrete-Filled Steel Tubular Arch Bridge Maintenance Based on Structural Health Monitoring

被引:4
|
作者
Gui, Chengzhong [1 ]
Lin, Weiwei [2 ]
Huang, Zuwei [3 ]
Xin, Guangtao [4 ]
Xiao, Jun [5 ]
Yang, Liuxin [6 ]
机构
[1] Inst Disaster Prevent, Sch Civil Engn, Sanhe 065201, Peoples R China
[2] Aalto Univ, Dept Civil Engn, Espoo 02100, Finland
[3] Minist Transport PRC, Highway Monitoring & Response Ctr, Beijing 100005, Peoples R China
[4] China Highway Engn Consulting Grp Co Ltd, Beijing 100089, Peoples R China
[5] CCCC Second Highway Engn Co Ltd, Xian 710199, Peoples R China
[6] Waseda Univ, Dept Civil & Environm Engn, Tokyo 1698555, Japan
关键词
structural health monitoring; bridge maintenance decision-making; degenerated ultimate loading-capacity state; finite element analysis; performance evaluation; parameter regression; parameter prediction; DAMAGE DETECTION; COLUMNS; IDENTIFICATION; NETWORK;
D O I
10.3390/ma15196920
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study focuses on establishing a novel heuristic algorithm for life-cycle performance evaluation. Special attention is given to decision-making algorithms for concrete-filled steel tubular (CFST) arch bridge maintenance. The main procedure is developed, including the ultimate loading-capacity modeling of CFST members, multi-parameter selection, ultimate thresholds presetting based on the finite element method, data processing, crucial parameters determination among sub-parameters, multi-parameter regression, ultimate state prediction, and system maintenance decision-making suggestions based on the multi-parameter performance evaluation. A degenerated ultimate loading-capacity model of CFST members is adopted in the finite element analysis and multi-parameter performance assessment. The multi-source heterogeneous data processing and temperature-effect elimination are performed for the data processing. The key sub-parameters were determined by the Principal Component Analysis method and the Entropy-weight method. The polynomial mathematical model is used in the multi-parameter regression, and the +/- 95% confidence bounds were verified. The system maintenance decision-making model combines the relative monitoring state, the relative ultimate state by the numerical analysis, and the relative residual life of degenerated members. The optimal system maintenance decision-making suggestions for the bridge maintenance system can be identified, including the most unfavorable maintenance time and parameter index. A case study on a CFST truss-arch bridge is conducted to the proposed algorithms. The obtained results demonstrated that the crack width deserves special attention in concrete bridge maintenance. Additionally, these technologies have enormous potential for the life-cycle performance assessment of the structural health monitoring system for existing concrete bridge structures.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Structural health monitoring system for special-shaped concrete-filled steel tubular arch bridge
    Miao C.
    Li A.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2011, 41 (06): : 1241 - 1246
  • [2] Level 2 safety evaluation of concrete-filled steel tubular arch bridges incorporating structural health monitoring and inspection information based on China bridge standards
    Li, Shunlong
    Ou, Jinping
    Wang, Junbo
    Gao, Xin
    Yang, Chun
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (03):
  • [3] Concrete-Filled Steel Tubular Tied Arch Bridge System: Application to Columbus Viaduct
    Morcous, G.
    Hanna, K.
    Deng, Y.
    Tadros, M. K.
    JOURNAL OF BRIDGE ENGINEERING, 2012, 17 (01) : 107 - 116
  • [4] Structural health monitoring of a concrete-filled tube column
    Younesi, A.
    Rezaifar, O.
    Gholhaki, M.
    Esfandiari, A.
    MAGAZINE OF CIVIL ENGINEERING, 2019, 85 (01): : 136 - 145
  • [5] Bearing capacity of an eccentric tubular concrete-filled steel bridge pier
    Sui, Weining
    Cheng, Haobo
    Wang, Zhanfei
    STEEL AND COMPOSITE STRUCTURES, 2018, 27 (03): : 285 - 295
  • [6] Vehicle-Bridge Coupling Vibration of Long-Span Concrete-Filled Steel Tubular Arch Bridge
    Yu, Peng
    Yu, Cun
    Ren, Zhaoyong
    Wang, Longlin
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2025, 25 (06)
  • [7] Effects of model updating on the estimation of stochastic seismic response of a concrete-filled steel tubular arch bridge
    Li, Xi
    Zhang, De-Yi
    Yan, Wei-Ming
    Xie, Wei-Chau
    Pandey, Mahesh D.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2014, 10 (12) : 1620 - 1637
  • [8] A Study on the Ultimate Span of a Concrete-Filled Steel Tube Arch Bridge
    Wu, Yuexing
    Wang, Xiangchuan
    Fan, Yonghui
    Shi, Jun
    Luo, Chao
    Wang, Xinzhong
    BUILDINGS, 2024, 14 (04)
  • [9] Stochastic seismic analysis of a concrete-filled steel tubular (CFST) arch bridge under tridirectional multiple excitations
    Zhang, De-Yi
    Li, Xi
    Yan, Wei-Ming
    Xie, Wei-Chau
    Pandey, Mahesh D.
    ENGINEERING STRUCTURES, 2013, 52 : 355 - 371
  • [10] Arch-Axis Coefficient Optimization of Long-Span Deck-Type Concrete-Filled Steel Tubular Arch Bridge
    Liu, Q. J.
    Wan, S.
    Liu, H. C.
    2017 4TH INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS, MECHANICS AND STRUCTURAL ENGINEERING (4TH AMMSE 2017), 2017, 269