Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery

被引:8
作者
Kobler, Jan-Philipp [1 ]
Prielozny, Lenka [2 ]
Lexow, G. Jakob [2 ]
Rau, Thomas S. [2 ]
Majdani, Omid [2 ]
Ortmaier, Tobias [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mechatron Syst, D-30167 Hannover, Germany
[2] Hannover Med Sch, D-30625 Hannover, NH, Germany
关键词
Surgical robotics; Bone anchor; Biomechanics; Mechanical characterization; CLINICAL VALIDATION; COCHLEAR; ACCURACY; SYSTEM;
D O I
10.1016/j.medengphy.2015.02.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimally invasive procedures while maintaining patient safety. In this paper, a method is presented to experimentally characterize the mechanical properties of the anchor bone linkage. A custom-built universal testing machine is used to measure the pullout strength as well as the spring constants of bone anchors seated in four different bone substitutes as well as in human cranial bone. Furthermore, the angles at which forces act on the bone anchors are varied to simulate realistic conditions. Based on the experimental results, a substitute material that has mechanical properties similar to those of cranial bone is identified. The results further reveal that the pullout strength of the investigated anchor design is sufficient with respect to the proposed application. However, both the measured load capacity as well as the spring constants vary depending on the load angles. Based on these findings, an alternative bone anchor design is presented and experimentally validated. Furthermore, the results serve as a basis for stiffness simulation and optimization of bone-attached microstereotactic frames. (C) 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:460 / 468
页数:9
相关论文
共 33 条
[1]   Clinical testing of an alternate method of inserting bone-implanted fiducial markers [J].
Balachandran, Ramya ;
Fritz, Mark A. ;
Dietrich, Mary S. ;
Danilchenko, Andrei ;
Mitchell, Jason E. ;
Oldfield, Veronica L. ;
Lipscomb, Wendy W. ;
Fitzpatrick, J. Michael ;
Neimat, Joseph S. ;
Konrad, Peter E. ;
Labadie, Robert F. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (05) :913-920
[2]   Percutaneous cochlear implant drilling via customized frames: An in vitro study [J].
Balachandran, Ramya ;
Mitchell, Jason E. ;
Blachon, Gregoire ;
Noble, Jack H. ;
Dawant, Benoit M. ;
Fitzpatrick, Michael ;
Labadie, Robert F. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2010, 142 (03) :421-426
[3]   Accuracy of Image-Guided Surgical Systems at the Lateral Skull Base as Clinically Assessed Using Bone-Anchored Hearing Aid Posts as Surgical Targets [J].
Balachandran, Ramya ;
Fitzpatrick, J. Michael ;
Labadie, Robert F. .
OTOLOGY & NEUROTOLOGY, 2008, 29 (08) :1050-1055
[4]  
Bickford J.H., 1995, INTRO DESIGN BEHAV B, V3rd
[5]  
Carano Aldo, 2005, Prog Orthod, V6, P82
[6]   Experimental study of the bone behaviour of the human skull bone for the development of a physical head model [J].
Delille, R. ;
Lesueur, D. ;
Potier, P. ;
Drazetic, P. ;
Markiewicz, E. .
INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2007, 12 (02) :101-108
[7]  
FIALA TGS, 1993, PLAST RECONSTR SURG, V92, P1227
[8]  
Kebernik M, 2005, THESIS MEDIZINSCHE F
[9]   An experimental evaluation of loads occurring during guided drilling for cochlear implantation [J].
Kobler, Jan-Philipp ;
Wall, Sergej ;
Lexow, G. Jakob ;
Lang, Carl Philipp ;
Majdani, Omid ;
Kahrs, Lueder A. ;
Ortmaier, Tobias .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (10) :1625-1637
[10]  
Kobler JP, 2014, IEEE INT CONF ROBOT, P2364, DOI 10.1109/ICRA.2014.6907187