The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails

被引:176
作者
Krettek, C [1 ]
Stephan, C [1 ]
Schandelmaier, P [1 ]
Richter, M [1 ]
Papa, HC [1 ]
Miclau, T [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30623 Hannover, Germany
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 06期
关键词
D O I
10.1302/0301-620X.81B6.10000
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intramedullary nailing of metaphyseal fractures may be associated with deformity as a result of instability after fixation, Our aim was to evaluate the clinical use of Poller screws (blocking screws) as a supplement to stability after fixation with statically locked intramedullary nails of small diameter. We studied, prospectively, 21 tibial fractures, 10 in the proximal third and 11 in the distal third in 20 patients after the insertion of Poller screws over a mean period of 18.5 months (12 to 29). All fractures had united. Healing was evident radiologically at a mean of 5.4 +/- 2.1 months (3 to 12) with a mean varus-valgus alignment of -1.0 degrees (-5 to 3) and mean antecurvatum-recurvatum alignment of 1.6 degrees (-6 to 11), The mean loss of reduction between placement of the initial Poller screw and follow-up was 0.5 degrees in the frontal plane and 0.4 degrees in the sagittal plane, There were no complications related to the Poller screw. The clinical outcome, according to the Karstrom-Olerud score, was not influenced by previous or concomitant injuries in 18 patients and was judged as excellent in three (17%), good in seven (39%), satisfactory in six (33%), fair in one (6%), and poor in one (6%).
引用
收藏
页码:963 / 968
页数:6
相关论文
共 15 条
[1]  
Ahlers J, 1992, Unfallchirurgie, V18, P31, DOI 10.1007/BF02588237
[2]  
BAKER S, 1997, J TRAUMA, V14, P187
[3]  
DONALD G, 1983, CLIN ORTHOP RELAT R, P64
[4]  
FREEDMAN EL, 1995, CLIN ORTHOP RELAT R, P25
[5]   PROBLEMS IN THE MANAGEMENT OF TYPE-III (SEVERE) OPEN FRACTURES - A NEW CLASSIFICATION OF TYPE-III OPEN FRACTURES [J].
GUSTILO, RB ;
MENDOZA, RM ;
WILLIAMS, DN .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1984, 24 (08) :742-746
[6]   INFLUENCES OF SOME DESIGN PARAMETERS ON THE BIOMECHANICS OF THE UNREAMED TIBIAL INTRAMEDULLARY NAIL [J].
HENLEY, MB ;
MEIER, M ;
TENCER, AF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :311-319
[7]  
KARLSTROM G, 1974, CLIN ORTHOP RELAT R, P82
[8]  
KRETTEK C, 1995, CLIN ORTHOP RELAT R, P34
[9]   Unreamed intramedullary nailing of femoral shaft fractures: Operative technique and early clinical experience with the standard locking option [J].
Krettek, C ;
Rudolf, J ;
Schandelmaier, P ;
Guy, P ;
Konemann, B ;
Tscherne, H .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (04) :233-254
[10]  
KRETTEK C, 1994, UNFALLCHIRURG, V97, P575