On-line chemiluminescence detection for capillary lan analysis

被引:95
作者
Huang, B [1 ]
Li, JJ [1 ]
Zhang, L [1 ]
Cheng, JK [1 ]
机构
[1] WUHAN UNIV,DEPT CHEM,WUHAN 430072,PEOPLES R CHINA
关键词
D O I
10.1021/ac9511253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive chemiluminescence detection for capillary ion analysis has been developed, The new idea lies in using the chemiluminescence reagent luminol as a component of the separation electrolyte, thus preventing loss of the light signal where luminol and H2O2 are mixed in advance in conventional now injection analysis or ion chromatography chemiluminescence detection, Signal enhancement is achieved by sample stacking injection in the electrophoresis process, The detection limit (S/N = 3) of 20 zmol (5 x 10(-13) mol/L) for cobalt(II) is similar to 2 orders of magnitude better than the most sensitive results (1.7 x 10(-11) mol/L) reported so far, Detection limits are 2 amol, 80 amol, 740 amol, and 100 fmol for copper(II), nickel(II), iron(III), and manganese(II), respectively, The sensitivity is significantly better than that in the electrochemical detection and the commonly used UV detection in capillary ion analysis. The capillary electrophoresis-chemiluminescence detector has been used to separate five metal ions, cobalt(II), copper(II), nickel(II), iron(III), and manganese(II), within 8 min with an average theoretical plate number of 4.6 x 10(5).
引用
收藏
页码:2366 / 2369
页数:4
相关论文
共 36 条
  • [1] CHEMI-LUMINESCENCE LIGHTS UP
    BRONSTEIN, I
    MCGRATH, P
    [J]. NATURE, 1989, 338 (6216) : 599 - 600
  • [2] BUCHBERGER W, 1993, J HIGH RES CHROMATOG, V16, P153
  • [3] OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS
    BURGI, DS
    CHIEN, RL
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (18) : 2042 - 2047
  • [4] CHEIN RL, 1992, ANAL CHEM, V64, pA489
  • [5] SEPARATION OF METAL-IONS BY CAPILLARY ELECTROPHORESIS
    CHEN, M
    CASSIDY, RM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2): : 425 - 431
  • [6] END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS
    DADOO, R
    SETO, AG
    COLON, LA
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (02) : 303 - 306
  • [7] Dadoo R., 1992, J HIGH RES CHROMATOG, V15, P133
  • [8] OPTIMIZATION OF A PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION SYSTEM FOR THE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FLUORESCENT COMPOUNDS
    DEJONG, GJ
    LAMMERS, N
    SPRUIT, FJ
    BRINKMAN, UAT
    FREI, RW
    [J]. CHROMATOGRAPHIA, 1984, 18 (03) : 129 - 133
  • [9] DETERMINATION OF SUBSTANCES AT LOW CONCENTRATIONS IN COMPLEX-MIXTURES BY ISOTACHOPHORESIS WITH COLUMN COUPLING
    EVERAERTS, FM
    VERHEGGEN, TPEM
    MIKKERS, FEP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB): : 21 - 38
  • [10] SIMULTANEOUS DETERMINATION OF CHROMIUM(III) AND CHROMIUM(VI) IN AQUEOUS-SOLUTIONS BY ION CHROMATOGRAPHY AND CHEMILUMINESCENCE DETECTION
    GAMMELGAARD, B
    JONS, O
    NIELSEN, B
    [J]. ANALYST, 1992, 117 (03) : 637 - 640