A Generic Open-Loop Algorithm for Three-Phase Grid Voltage/Current Synchronization With Particular Reference to Phase, Frequency, and Amplitude Estimation

被引:115
|
作者
Freijedo, Francisco D. [1 ]
Doval-Gandoy, Jesus [1 ]
Lopez, Oscar [1 ]
Acha, Enrique [2 ]
机构
[1] Univ Vigo, Dept Elect Technol, Vigo 36310, Spain
[2] Univ Glasgow, Dept Elect & Elect Engn, Glasgow G12 8QQ, Lanark, Scotland
关键词
Grid-connected converters; phase-locked loop (PLL); predictive control; synchronization; PREDICTIVE CURRENT CONTROL; ACTIVE POWER FILTER; DIGITAL REPETITIVE CONTROL; LOCKED LOOP; VOLTAGE-SOURCE; CURRENT CONTROLLER; PERFORMANCE; CONVERTER; IMPROVEMENT; RECTIFIERS;
D O I
10.1109/TPEL.2008.2005580
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new open-loop architecture for three-phase grid synchronization based on moving average and predictive filters, where accurate measurements of phase, frequency, and amplitude are carried out in real time. Previous works establish that the fundamental positive sequence vector of a set of utility voltage/current vectors can be decoupled using Park's transformation and low-pass filters. However, the filtering process introduces delays that impair the system performance. More specifically, when the input signal frequency is shifted above the nominal, a nonzero average steady-state phase error appears in the measurements. To overcome such limitations, a suitable combination of predictive and moving average finite impulse response (FIR) filters is used by the authors to achieve a robust synchronization system for all input frequencies. Moving average filters are linear phase FIR filters that have a constant time delay at low frequencies, a characteristic that is exploited to good effect to design a predictive filter that compensates such time delays, enabling zero steady-state phase errors for shifted input frequencies. In summary, the main attributes of the new system are its good frequency adaptation, good filtering/transient response tradeoff, and the fact that its dynamics is independent of the input vector amplitude. Comprehensive experimental results validate the theoretical approach and the high performance of the proposed synchronization algorithm.
引用
收藏
页码:94 / 107
页数:14
相关论文
共 50 条
  • [41] Current predictive control of three-phase voltage source PWM rectifiers under unbalanced grid voltage conditions
    Wang, Meng
    Shi, Yanyan
    Qi, Zhen
    Shen, Minghui
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2017, 39 (07) : 976 - 986
  • [42] A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages
    Kim, Kwang-Seob
    Hyun, Dong-Seok
    Kim, Rae-Yong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 1101 - 1107
  • [43] A Novel Low Voltage Ride-Through Technique of Three-Phase Grid-Connected Inverters Based on a Nonlinear Phase-Locked Loop
    Sun, Guangyu
    Li, Yongli
    Jin, Wei
    Li, Song
    Gao, Yan
    IEEE ACCESS, 2019, 7 : 66609 - 66622
  • [44] An Enhanced Single-Phase Self-Tuning Filter based Open-Loop Frequency Estimator for Weak Grid
    Verma, Anant Kumar
    Ahmed, Hafiz
    Roncero-Sanchez, Pedro
    Chaturvedi, Pradyumn
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 1020 - 1025
  • [45] A Synchronous Reference Frame Robust Predictive Current Control for Three-Phase Grid-Connected Inverters
    Espi Huerta, Jose M.
    Castello-Moreno, Jaime
    Roberto Fischer, Jonatan
    Garcia-Gil, Rafael
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (03) : 954 - 962
  • [46] An Open-Circuit Fault Diagnosis for Three-Phase PWM Rectifier Without Grid Voltage Sensor Based on Phase Angle Partition
    Li, Chunjie
    Hu, Jianing
    Zhao, Mingwei
    Zeng, Wei
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2024, 71 (11) : 5318 - 5328
  • [47] Unbalanced three-phase distribution system frequency estimation using least mean squares method and positive voltage sequence
    Marcetic, Darko P.
    Tomic, Josif J.
    Kusljevic, Miodrag D.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2014, 8 (01) : 30 - 38
  • [48] Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-Phase Grid-Interfaced Converters in Distributed Utility Networks
    Guo, Xiaoqiang
    Wu, Weiyang
    Chen, Zhe
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) : 1194 - 1204
  • [49] Control Strategy to Eliminate Impact of Voltage Measurement Errors on Grid Current Performance of Three-Phase Grid-Connected Inverters
    Quoc-Nam Trinh
    Choo, Fook Hoong
    Wang, Peng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) : 7508 - 7519
  • [50] Accurate Estimation of Positive- and Negative-Sequence Components for Three-Phase Grid Voltage Under Disturbances
    Zhao, Peiqi
    Li, Bingqiang
    Zhang, Zhen
    Zhou, Xiangyu
    Dai, Zhiyong
    Meng, Yongqing
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (03) : 2952 - 2962