Validation of high-performance liquid chromatographic-mass spectrometric method for the analysis of lidocaine in human plasma

被引:16
作者
Chik, Z.
Lee, T. D.
Holt, D. W.
Johnston, A.
Tucker, A. T.
机构
[1] Barts & London Queen Marys Sch Med & Dent, William Harvey Res Inst, London EC1M 6BQ, England
[2] St George Hosp, Sch Med, Analyt Unit, London SW17 0RE, England
关键词
D O I
10.1093/chromsci/44.5.262
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and simple liquid chromatography-tandem mass spectrometry method is developed and validated for the determination of lidocaine in human plasma. Bupivacaine is used as an internal standard, and the plasma extraction is performed by a simple liquid-liquid extraction. The limit of quantitation (LOQ) is 0.5 ng/mL with a signal-to-noise ratio greater than 5. The calibration curve is linear from 0.5 to 250 ng/mL with an r2 greater than 0.99. The coefficients of variation for within- and between-assay imprecision, including LOQ, are ≤ 13% and ≤ 8%, respectively. The percentage of inaccuracy for within- and between-assay, including LOQ, are ≤ 9% and ≤ 5%, respectively. The absolute recovery of lidocaine and bupivacaine are greater than 84% and 82%, respectively. The higher sensitivity and accuracy of this method allow the measurement of low concentrations of lidocaine in plasma from a clinical study of topically applied lidocaine in healthy subjects.
引用
收藏
页码:262 / 265
页数:4
相关论文
共 8 条
  • [1] High-performance liquid chromatography-tandem electrospray mass spectrometry for the determination of lidocaine and its metabolites in human plasma and urine
    Abdel-Rehim, M
    Bielenstein, M
    Askemark, Y
    Tyrefors, N
    Arvidsson, T
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 175 - 188
  • [2] ADAMS H A, 1989, Regional-Anaesthesie, V12, P53
  • [3] [Anonymous], 2013, Guidance for Industry: Bioanalytical Method Validation
  • [4] A QUICK, SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ASSAY FOR MONOETHYLGLYCINEXYLIDIDE AND LIGNOCAINE IN SERUM PLASMA USING SOLID-PHASE EXTRACTION
    CHEN, Y
    POTTER, JM
    RAVENSCROFT, PJ
    [J]. THERAPEUTIC DRUG MONITORING, 1992, 14 (04) : 317 - 321
  • [5] Highly sensitive bioassay of lidocaine in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Dal Bo, L
    Mazzucchelli, P
    Marzo, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 3 - 11
  • [6] THE HEPATIC 1ST-PASS METABOLISM OF PROBLEMATIC DRUGS
    LALKA, D
    GRIFFITH, RK
    CRONENBERGER, CL
    [J]. JOURNAL OF CLINICAL PHARMACOLOGY, 1993, 33 (07) : 657 - 669
  • [7] PREDICTION OF BIOAVAILABILITY FOR DRUGS WITH A HIGH 1ST-PASS EFFECT USING ORAL CLEARANCE DATA
    SOMOGYI, A
    EICHELBAUM, M
    GUGLER, R
    [J]. EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 22 (01) : 85 - 90
  • [8] Simple analysis of local anaesthetics in human blood using headspace solid-phase microextraction and gas chromatography mass spectrometry electron impact ionization selected ion monitoring
    Watanabe, T
    Namera, A
    Yashiki, M
    Iwasaki, Y
    Kojima, T
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02): : 225 - 232