Improved microcalcification visualization using dual-energy digital mammography

被引:2
作者
Tsai, Chia-Jung [1 ]
Chen, Ran-Chou [2 ,3 ]
Peng, Hui-Ling [4 ]
Hsu, Wen-Lin [5 ,6 ]
Lee, Jason J. S. [2 ]
机构
[1] Chung Shan Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[2] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
[3] Taipei City Hosp, Dept Radiol, Taipei, Taiwan
[4] Shin Kong Wu Ho Su Mem Hosp, Dept Diagnost Radiol, Taipei, Taiwan
[5] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Radiat Oncol, Hualien, Taiwan
关键词
Dual-energy digital mammography; microcalcification; radiation dose; FILM MAMMOGRAPHY; SUBTRACTION MAMMOGRAPHY; BREAST TOMOSYNTHESIS; OPTIMIZATION; TISSUE; CT;
D O I
10.1177/0284185113481017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Dual-energy digital mammography (DEDM), involving a combination of high-energy (HE) and low-energy (LE) images, has been investigated as offering a potential improvement in microcalcification detection obscured by overlapping tissue structures. Purpose: To explore the possibility to improve detection of microcalcifications using the DEDM technique. Material and Methods: Three DEDM protocols were performed by adjusting the effective tube current time product (mAs) of LE image at the same (100%), one half (50%), and one-quarter (25%) of that used in HE image acquisition, named DEDM100%, DEDM50%, and DEDM25%, respectively. A single-energy digital mammography (SEDM) method was also used as a control. A total of 525 regions of interest (ROIs) were used to compare the performance of the DEDM to that of SEDM using free-response receiver-operating characteristic (FROC) and areas under the FROC curve (A(z)). Results: All DEDM protocols ranked significantly higher than the SEDM method (P < 0.001). The true-positive fraction was 0.90 for an average of 0.017-0.042 false-positive per image using the DEDM100%, 0.017-0.114 using the DEDM50%, 0.021-0.148 using the DEDM25%, and 0.134-0.422 using the SEDM. The estimated Az values were 0.915-0.940, 0.867-0.935, 0.824-0.930, and 0.567-0.673, respectively. Conclusion: The DEDM50% protocol provided a trade-off benefit between accurate microcalcification detectability and radiation dose for any tissue density. Therefore, the DEDM50% has the potential to minimize excess radiation dose without a negative impact on image quality which could improve earlier diagnosis of breast cancer.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 39 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography [J].
Baldelli, P. ;
Bravin, A. ;
Di Maggio, C. ;
Gennaro, G. ;
Sarnelli, A. ;
Taibi, A. ;
Gambaccini, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17) :4233-4251
[3]   Dual-energy mammography: simulation studies [J].
Bliznakova, K. ;
Kolitsi, Z. ;
Pallikarakis, N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) :4497-4515
[4]   DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[5]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[6]   Single-shot dual-energy subtraction mammography with electronic spectrum splitting: Feasibility [J].
Bornefalk, Hans ;
Lewin, John M. ;
Danielsson, Mats ;
Lundqvist, Mats .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (02) :275-278
[7]   Evaluation of dual-energy subtraction of digital mammography images under conditions found in a commercial unit [J].
Brandan, ME ;
Ramírez, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09) :2307-2320
[8]   A METHOD FOR SELECTIVE TISSUE AND BONE VISUALIZATION USING DUAL ENERGY SCANNED PROJECTION RADIOGRAPHY [J].
BRODY, WR ;
BUTT, G ;
HALL, A ;
MACOVSKI, A .
MEDICAL PHYSICS, 1981, 8 (03) :353-357
[9]   Dual-energy contrast-enhanced digital breast tomosynthesis - a feasibility study [J].
Carton, A-K ;
Gavenonis, S. C. ;
Currivan, J. A. ;
Conant, E. F. ;
Schnall, M. D. ;
Maidment, A. D. A. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (988) :344-350
[10]   Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation [J].
Carton, Ann-Katherine ;
Ullberg, Christer ;
Maidment, Andrew D. A. .
MEDICAL PHYSICS, 2010, 37 (11) :5908-5913