Membrane bioreactors in industrial wastewater treatment - European experiences, examples and trends

被引:37
作者
Cornel, P [1 ]
Krause, S [1 ]
机构
[1] Tech Univ Darmstadt, Inst WAR, D-64287 Darmstadt, Germany
关键词
mBR; design; pre-treatment; oxygen transfer; industrial applications;
D O I
10.2166/wst.2006.074
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In wastewater treatment, micro- and ultra-filtration membranes are used for the separation of the activated sludge (biomass) from the treated water. This offers the advantages of a complete removal of solids and bacteria, as well as most of the viruses, namely those attached to the suspended solids. Compared to the conventional activated sludge process (CAS) this technology allows a much higher biomass concentration (MLSS) whereby the reactor volume and the footprint decreases. With increasing MLSS, the viscosity of the sludge increases, which leads to reduced oxygen transfer rates. Depending on the type of membrane and membrane module, the pre-treatment has to be more sophisticated to prevent clogging and sludging of the modules. Due to fouling and scaling, the flux through the membranes will decrease with time. The decrease depends on the water quality as well as on the measurements taken to minimize fouling. Mainly, three strategies are available: lowering the flux, increasing the "crossflow" and cleaning of the membranes. Different strategies including backwash and chemical cleaning "in situ", "on air" and "ex situ" can be applied. It has been proven more effective to apply preventive regular cleaning. Besides the energy demand for oxygen supply - which is typically in the range of 0.3 kWh/m(3) for municipal wastewater - the energy for fouling prevention is substantial. Immersed membranes need approximately 0.4 to 1 kWh/m(3) -:or the coarse bubble aeration, whereas tubular modules require 1 to 4 kWh/m3 pump energy. For proper design of industrial wastewater treatment, the verification of applicability and the development of adequate cleaning strategies, it is a precondition to run pilot tests for a sufficient period of time with the wastewater to be treated. More than 100 industrial wastewater treatment membrane bioreactors (MBR) are in operation in Europe. Data of three case studies for a sewage sludge dewatering plant in UK (12,000 m(3)/d), a plant for the treatment of pharmaceutical wastewater in Germany (3,600 m(3)/d), as well for revamping of an chemical WWTP > 2,000 m(3)/d in Italy, are given. MBRs will be used in future wherever high quality effluent is required, because of a sensitive receiving water body or due to the fact of water reuse as process water. MBRs are a perfect pre-treatment in industrial applications when further treatment with nanofiltration or reverse osmosis is considered. The technique is advanced and can be applied both in municipal and industrial wastewater treatment. Higher operational costs must be balanced by superior effluent quality.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 50 条
  • [21] Cake layer formation in anaerobic submerged membrane bioreactors (AnSMBR) for wastewater treatment
    Jeison, D.
    van Lier, J. B.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 284 (1-2) : 227 - 236
  • [22] Optimization of full-scale membrane bioreactors for wastewater treatment through a model-based approach
    Gabarron, S.
    Dalmau, M.
    Porro, J.
    Rodriguez-Roda, I.
    Comas, J.
    CHEMICAL ENGINEERING JOURNAL, 2015, 267 : 34 - 42
  • [23] A practitioner's perspective on the application and research needs of membrane bioreactors for municipal wastewater treatment
    Kraemer, Jeremy T.
    Menniti, Adrienne L.
    Erdal, Zeynep K.
    Constantine, Timothy A.
    Johnson, Bruce R.
    Daigger, Glen T.
    Crawford, George V.
    BIORESOURCE TECHNOLOGY, 2012, 122 : 2 - 10
  • [24] Municipal wastewater treatment with anaerobic membrane Bioreactors for non-potable reuse: A review
    Huang, Yu
    Jeffrey, Paul
    Pidou, Marc
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024, 54 (10) : 817 - 839
  • [25] Modeling of Wastewater Treatment Processes in Membrane Bioreactors Compared to Conventional Activated Sludge Systems
    Bis, Marta
    Montusiewicz, Agnieszka
    Piotrowicz, Adam
    Lagod, Grzegorz
    PROCESSES, 2019, 7 (05)
  • [26] Impact of Na+ on Biological Wastewater Treatment and the Potential of Anaerobic Membrane Bioreactors: A Review
    Yang, Jixiang
    Spanjers, Henri
    Jeison, David
    Van Lier, Jules B.
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013, 43 (24) : 2722 - 2746
  • [27] Scope of aerobic and anaerobic membrane bioreactor in industrial wastewater treatment
    Bhaduri, Soumyadeep
    Mazumder, Debabrata
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2020, 97 (12B) : 2771 - 2776
  • [28] Membrane fouling mitigation by NaClO-assisted backwash in anaerobic ceramic membrane bioreactors for the treatment of domestic wastewater
    Yue, Xiaodi
    Koh, Yoong Keat Kelvin
    Ng, How Yong
    BIORESOURCE TECHNOLOGY, 2018, 268 : 622 - 632
  • [29] Sustaining membrane permeability during unsteady-state operation of anaerobic membrane bioreactors for municipal wastewater treatment following peak-flow
    Wang, K. M.
    Jefferson, B.
    Soares, A.
    McAdam, E. J.
    JOURNAL OF MEMBRANE SCIENCE, 2018, 564 : 289 - 297
  • [30] Comparison between aerobic and anaerobic membrane bioreactors for trace organic contaminant removal in wastewater treatment
    Liu, Wancen
    Song, Xiaoye
    Huda, Nazmul
    Xie, Ming
    Li, Guoxue
    Luo, Wenhai
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2020, 17