Bioelectrical impedance analysis before versus after a hemodialysis session in evaluation of nutritional status

被引:12
作者
Jankowska, M [1 ]
Debska-Slizien, A [1 ]
Rutkowski, B [1 ]
机构
[1] Med Univ Gdansk, Dept Nephrol Transplantol & Internal Med, Gdansk, Poland
关键词
D O I
10.1053/j.jrn.2006.01.005
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: The objective of our study was to evaluate whether bioelectrical impedance analysis (BIA) performed 15 minutes after a hemodialysis (HID) session is clinically useful in nutrition status assessment in comparison with BIA performed before HID. Because of better reliability, it is postulated in the literature that BIA measurements should be performed 1 to 5 hours after HID sessions. However, the measurements 1 to 5 hours after HID sessions are inconvenient in clinical practice. Furthermore, the currently published BIA reference values for the HID population are based on the measurements taken before HID sessions. Methods: The study group consisted of 29 HID patients who were in a stable clinical condition. BIA measurements were performed by means of BIA 101 System (Akern RJL Systems, Florence, Italy). The correlation coefficients were surveyed between traditional indices of nutritional status, such as body mass index (BMI) and plasma concentrations of protein, albumin, and nonprotein nitrogen blood urea nitrogen (BUN) (measured before HID) on one hand, and BIA parameters (taken before and 15 minutes after HID) on the other hand. Results: Statistically significant correlations occurred between such BIA parameters as (1) phase angle and BMI or albumin, or total protein or BUN and (2) body cell mass and BMI or BUN. The differences between correlation coefficients achieved either before or after HID were statistically nonsignificant. Conclusions: BIA measurements in the studied group of patients did correlate with traditional indices of nutritional status. The correlation coefficients were not significantly influenced by the time of performing BIA measurements. The obtained correlations confirm that BIA performed 15 minutes after an HID session may be a useful tool in evaluation of nutritional status of stable HID patients in clinical practice. (c) 2006 by the National Kidney Foundation, Inc.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 50 条
[21]   USE OF BIOELECTRICAL IMPEDANCE FOR THE NUTRITIONAL ASSESSMENT OF CHRONIC-HEMODIALYSIS PATIENTS [J].
DUMLER, F ;
SCHMIDT, R ;
KILATES, C ;
FABER, M ;
LUBKOWSKI, T ;
FRINAK, S .
MINERAL AND ELECTROLYTE METABOLISM, 1992, 18 (2-5) :284-287
[22]   Detection of hydration status by total body bioelectrical impedance analysis (BIA) in patients on hemodialysis [J].
Oe, B ;
DeFijter, WM ;
DeFijter, CWH ;
Straver, B ;
Oe, PL ;
Stevens, F ;
DeVries, PMJM .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (07) :371-374
[23]   Application of bioelectrical impedance vector analysis to evaluate volume status of hemodialysis patients with hypertension [J].
陈海燕 .
China Medical Abstracts(Internal Medicine), 2020, 37 (03) :184-184
[24]   Measurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy [J].
Bartok, C ;
Atkinson, RL ;
Schoeller, DA .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (01) :225-232
[25]   NUTRITIONAL STATUS ASSESSMENT BY BIOELECTRICAL IMPEDANCE ANALYSIS: COMPARISON IN PATIENTS WITH CHRONIC PANCREATITIS AND CIRRHOSIS [J].
Singh, Namrata ;
Grover, Indu ;
Gunjan, Deepak ;
Upadhyay, Ashish Datt ;
Saraya, Anoop .
GASTROENTEROLOGY, 2018, 154 (06) :S718-S719
[26]   The use of bioelectrical impedance vector analysis for a nutritional evaluation of older adults in the community [J].
Goes, Andrea Costa ;
Santos, Mylena Alves ;
Oliveira, Rafaela de Siqueira ;
Oliveira, Juliana de Souza ;
Roriz, Anna Karla Carneiro ;
de Oliveira, Carolina Cunha .
EXPERIMENTAL GERONTOLOGY, 2021, 147
[27]   Anthropometrical and Bioelectrical Impedance Analysis Parameters in Anorexia Nervosa Patients' Nutritional Status Assessment [J].
Popiolek, Joanna ;
Teter, Mariusz ;
Kozak, Gustaw ;
Powrozek, Tomasz ;
Mlak, Radoslaw ;
Karakula-Juchnowicz, Hanna ;
Malecka-Massalska, Teresa .
MEDICINA-LITHUANIA, 2019, 55 (10)
[28]   Control of Hemodialysis Therapy Based on the Bioelectrical Impedance Analysis [J].
Krutko D.M. ;
Mazurenko S.O. ;
Staroselsky K.G. ;
Ermolaeva L.G. ;
Ivanov I.G. .
Biomedical Engineering, 2016, 50 (03) :189-191
[29]   Bioelectrical impedance analysis predicts survival in hemodialysis patients [J].
Chertow, GM ;
Lowrie, EG ;
Lew, NL ;
Lazarus, JM .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09) :A0969-A0969
[30]   Diagnostic Accuracy of Bioelectrical Impedance Analysis Parameters for the Evaluation of Malnutrition in Patients Receiving Hemodialysis [J].
da Silva, Angela Teodosio ;
Hauschild, Daniela Barbieri ;
Franco Moreno, Yara Maria ;
Dornelles Bastos, Joao Luiz ;
Wazlawik, Elisabeth .
NUTRITION IN CLINICAL PRACTICE, 2018, 33 (06) :831-842