Performance assessment of residential mechanical exhaust ventilation systems dimensioned in accordance with Belgian, British, Dutch, French and ASHRAE standards

被引:23
作者
Laverge, J. [1 ]
Pattyn, X. [1 ]
Janssens, A. [1 ]
机构
[1] Univ Ghent, Dept Architecture & Urban Planning, B-9000 Ghent, Belgium
关键词
Exhaust ventilation; Residential ventilation; Pareto; Monte-Carlo; IAQ; INDOOR AIR-QUALITY; CONTAMINANT TRANSPORT; SENSITIVITY-ANALYSIS; HOUSEHOLD PRODUCTS; CROSS-VENTILATION; MODEL EVALUATION; SIMULATION; FLOW; POLLUTION; COOKING;
D O I
10.1016/j.buildenv.2012.08.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sizing rules in residential ventilation standards lack uniformity in both methodology and resulting design flow rates. Additionally, mere comparison of design flow rates is case sensitive and, due to effects of infiltration, adventitious ventilation and occupancy, ill-suited to assess performance of an exhaust ventilation system with regard to the achieved indoor air quality and energy cost in terms of heat loss. This paper presents a multi-zone simulation based performance assessment of residential mechanical exhaust ventilation systems, using five common dwelling typologies and the sizing rules put forward in the Belgian, British, Dutch, French and ASHRAE residential ventilation standards. The performance of the different cases proved to be substantially different, with an occurrence of poor perceived air quality in 5% or less of the occupation time for the Belgian, Dutch and French standard, and about 15% for the British and ASHRAE standard. When the trade-off between indoor air quality and heat loss is considered, the cases with the Dutch and ASHRAE standard did not achieve pareto optimal performance in comparison to the performances achieved by the other standards. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 75 条
[1]   Performance evaluation of natural ventilation strategies for hospital wards - A case study of Great Ormond Street Hospital [J].
Adamu, Z. A. ;
Price, A. D. F. ;
Cook, M. J. .
BUILDING AND ENVIRONMENT, 2012, 56 :211-222
[2]  
[Anonymous], EN BAL OECD COUNTR 2
[3]  
[Anonymous], ASHRAE T
[4]  
[Anonymous], 2007, VENT NONR BUILD PERF
[5]  
ASHRAE, 2010, VENT ACC IND QUAL LO
[6]   American time use survey: Sleep time and its relationship to waking activities [J].
Basner, Mathias ;
Fomberstein, Kenneth M. ;
Razavi, Farid M. ;
Banks, Siobhan ;
William, Jeffrey H. ;
Rosa, Roger R. ;
Dinges, David F. .
SLEEP, 2007, 30 (09) :1085-1095
[7]   Patterns and predictors of personal exposure to indoor air pollution from biomass combustion among women and children in rural China [J].
Baumgartner, J. ;
Schauer, J. J. ;
Ezzati, M. ;
Lu, L. ;
Cheng, C. ;
Patz, J. ;
Bautista, L. E. .
INDOOR AIR, 2011, 21 (06) :479-488
[8]   Improving energy performance of school buildings while ensuring indoor air quality ventilation [J].
Becker, Rachel ;
Goldberger, Itamar ;
Paciuk, Monica .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3261-3276
[9]  
BIN, 1991, VENT WOONG
[10]  
Bosh J, 2007, PANORAMA ENERGY ENER