An anatomic consideration of C2 vertebrae artery groove variation for individual screw implantation in axis

被引:49
作者
Wang, Janhua [1 ]
Xia, Hong [1 ]
Ying, Qingshui [1 ]
Lu, Yang [2 ]
Wu, Zenghui [1 ]
Ai, Fzhi [1 ]
Ma, Xiangyang [1 ]
机构
[1] Gen Mil Hosp Guangzhou Command, Liu Hua Qiao Hosp, Dept Orthopaed Surg, Guangzhou 510010, Guangdong, Peoples R China
[2] Univ Illinois Hosp & Hlth Sci Syst, Dept Radiol, Chicago, IL 60612 USA
关键词
Safe zone; C2 vertebral artery groove (VAG); C2 pedicle screw; C2 translaminar screw; Individual screw placement; CERVICAL PEDICLE SCREWS; FIXATION TECHNIQUES; POSTERIOR FIXATION; POLYAXIAL SCREW; PLACEMENT; INJURY; PLATE; RISK;
D O I
10.1007/s00586-013-2779-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Retrospective case series. To identify the variation of C2 vertebral artery groove (VAG) based on the thin-slice computed tomography (CT) scan and choose an individual screw placement method to decrease risk of malposition. C2 pedicle screws can be successful anchors for a variety of cervical disorders. However, variations of VAG may cause malposition and breach when C2 transpedicle screw was inserted. Recognizing the variations of vertebrae artery groove (VAG) in C2 and choosing an individual screw placement method (transpedicle or translaminar) may be helpful for avoiding violation and decreasing the operation risk in upper cervical surgery. From January 2009 to December 2010, a total 45 patients with upper cervical disorders underwent 1-mm-thin-slice CT scans along the C2 pedicle direction to obtain the consecutive spectrum of C2 VAG were included in this study. The C2 VAG (types I, II, III, and IV) was subgrouped based on parameter e (the vertical distance from the apex of VAG to the upper facet joint surface) and parameter a (horizontal distance from the entrance of VAG to the vertebrae canal). Subsequently, individual strategy was used to avoid the VAG violation. The variations of C2 VAG in these 45 patients include the following: type I 53 (58.9 %), type II 16 (17.8 %) type III 13 (14.4 %), and type IV 8 (8.9 %). Transpedicle screws of C2 were used in types I, III, and IV VAGs (n = 74); translaminar screws were inserted in type II subgroup (n = 16). Postoperative CT scans showed that there were two pedicle screws violated into the artery groove, and no translaminar screw breached into the vertebrae canal. All the other screws were in right position. None of the 45 patients had severe complications such as spinal cord injury, dura tear, and infection. Thin-slice CT scan along the C2 pedicle direction to analysis the variations of C2 VAG can help choose an individual screw placement method (transpedicle or translaminar) with minimal complication for C2 screw fixation.
引用
收藏
页码:1547 / 1552
页数:6
相关论文
共 15 条
[1]   Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems [J].
Abumi, K ;
Takada, T ;
Shono, Y ;
Kaneda, K ;
Fujiya, M .
SPINE, 1999, 24 (14) :1425-1434
[2]   Preoperative Radiographic Factors and Surgeon Experience Are Associated With Cortical Breach of C2 Pedicle Screws [J].
Alosh, Hassan ;
Parker, Scott L. ;
McGirt, Matthew J. ;
Gokaslan, Ziya L. ;
Witham, Timothy F. ;
Bydon, Ali ;
Wolinsky, Jean-Paul ;
Sciubba, Daniel M. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (01) :9-14
[3]   Posterior Fixation of the Upper Cervical Spine: Contemporary Techniques [J].
Bransford, Richard J. ;
Lee, Michael J. ;
Reis, Abilio .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (02) :63-71
[4]   Atlantoaxial fixation using, plate and screw method: A report of 160 treated patients [J].
Goel, A ;
Desai, KI ;
Muzumdar, DP .
NEUROSURGERY, 2002, 51 (06) :1351-1356
[5]   Posterior C1-C2 fusion with polyaxial screw and rod fixation [J].
Harms, J ;
Melcher, RP .
SPINE, 2001, 26 (22) :2467-2471
[6]   The use of CT in the development and implementation of a preoperative protocol to aid in pedicle screw placement during scoliosis surgery [J].
Jamieson, Douglas ;
Perdios, Angeliki ;
Varghese, Renjit ;
Reilly, Christopher W. .
PEDIATRIC RADIOLOGY, 2008, 38 (04) :452-456
[7]   The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae [J].
Neo, M ;
Sakamoto, T ;
Fujibayashi, S ;
Nakamura, T .
SPINE, 2005, 30 (24) :2800-2805
[8]   Stability analysis of craniovertebral junction fixation techniques [J].
Puttlitz, CM ;
Melcher, RP ;
Kleinstueck, FS ;
Harms, J ;
Bradford, DS ;
Lotz, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03) :561-568
[9]   Anatomic suitability of the C1-C2 complex for pedicle screw fixation [J].
Resnick, DK ;
Lapsiwala, S ;
Trost, GR .
SPINE, 2002, 27 (14) :1494-1498
[10]   Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome [J].
Ringel, Florian ;
Reinke, Andreas ;
Stueer, Carsten ;
Meyer, Bernhard ;
Stoffel, Michael .
ACTA NEUROCHIRURGICA, 2012, 154 (02) :305-312