The detection of carbon monoxide by cavity enhanced absorption spectroscopy with a DFB diode laser

被引:6
作者
Pei, SX [1 ]
Cui, FP
Gao, XM
Zhao, WX
Yang, Y
Huang, T
Huang, W
Zhang, WJ
机构
[1] Nanjing Univ Informat Sci & Technol, Dept Phys, Nanjing 210044, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Lab Environm Spectroscopy, Hefei 230031, Peoples R China
基金
中国国家自然科学基金;
关键词
spectroscopy; CEAS; CRDS; TDL; CO;
D O I
10.1016/j.vibspec.2005.09.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It has been proven that cavity enhanced absorption spectroscopy is a high sensitive spectral technique. The aim of our study was to apply this spectral technique to the detection of carbon monoxide with a narrow line width tunable DFB diode laser and high Q factor optical cavity. Absorption signals were extracted from a measurement recording the average of 20 highest light intensities that leak out of the cavity. The absorption spectrum of CO centered at 6354.18 cm(-1) was recorded; the experiment results indicate that cavity enhanced absorption spectroscopy could produce accurate high resolution spectrum. A detection sensitivity about 5.687 x 10(-7) cm(-1) has been achieved in a 45 cm-long cell. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 14 条
[1]   Broadband cavity ringdown spectroscopy of the NO3 radical [J].
Ball, SM ;
Povey, IM ;
Norton, EG ;
Jones, RL .
CHEMICAL PHYSICS LETTERS, 2001, 342 (1-2) :113-120
[2]   High-resolution cavity enhanced absorption spectroscopy using an optical cavity with ultra-high reflectivity mirrors [J].
Cheung, ASC ;
Ma, TM ;
Chen, HB .
CHEMICAL PHYSICS LETTERS, 2002, 353 (3-4) :275-280
[3]   Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy [J].
Engeln, R ;
Berden, G ;
Peeters, R ;
Meijer, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3763-3769
[4]   Polarization dependent cavity ring down spectroscopy [J].
Engeln, R ;
Berden, G ;
vandenBerg, E ;
Meijer, G .
JOURNAL OF CHEMICAL PHYSICS, 1997, 107 (12) :4458-4467
[5]   TRACE GAS-DETECTION WITH CAVITY RING DOWN SPECTROSCOPY [J].
JONGMA, RT ;
BOOGAARTS, MGH ;
HOLLEMAN, I ;
MEIJER, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (04) :2821-2828
[6]   COHERENT CAVITY RING DOWN SPECTROSCOPY [J].
MEIJER, G ;
BOOGAARTS, MGH ;
JONGMA, RT ;
PARKER, DH ;
WODTKE, AM .
CHEMICAL PHYSICS LETTERS, 1994, 217 (1-2) :112-116
[7]   cw Integrated cavity output spectroscopy [J].
O'Keefe, A ;
Scherer, JJ ;
Paul, JB .
CHEMICAL PHYSICS LETTERS, 1999, 307 (5-6) :343-349
[8]   CAVITY RING-DOWN OPTICAL SPECTROMETER FOR ABSORPTION-MEASUREMENTS USING PULSED LASER SOURCES [J].
OKEEFE, A ;
DEACON, DAG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (12) :2544-2551
[9]  
OKEEFE A, 1990, CHEM PHYS LETT, V172, P215
[10]   CAVITY RING-DOWN OVERTONE SPECTROSCOPY OF HCN, (HCN)-C-13 AND (HCN)-N-15 [J].
ROMANINI, D ;
LEHMANN, KK .
JOURNAL OF CHEMICAL PHYSICS, 1995, 102 (02) :633-642