Towards an integrated analysis of the indoor environmental factors and its effects on occupants

被引:76
作者
Bluyssen, Philomena M. [1 ]
机构
[1] Delft Univ Technol, Fac Architecture & Built Environm, Chair Indoor Environm, Delft, Netherlands
关键词
Integrated analysis; indoor environment; health and comfort; occupants; interactions; SICK BUILDING SYNDROME; SELF-REPORTED HEALTH; COGNITIVE PERFORMANCE; SCHOOL-CHILDREN; SBS SYMPTOMS; OFFICE NOISE; AIR-QUALITY; COMFORT; HEAT; DISTRACTION;
D O I
10.1080/17508975.2019.1599318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research has shown that staying indoors is not good for our health, even though the conditions seem to comply with current guidelines for indoor environmental quality (IEQ). The growing field of indoor health and comfort studies in schools, offices and homes, shows a discrepancy of current standards with end-users needs. In a previous review it was concluded that a more complex research model than the conventional `dose-response' model is required to explain symptoms and complaints, preferences and needs, in order to prevent negative effects and to stimulate positive experiences. In this position paper, recent research on the further development of the previous introduced approach is presented along the identified needs, i.e. a model that is suitable for determining patterns of stressors and interactions, and takes account of dynamic behaviour over time per scenario; assessment methods that can identify other factors and stressors than the environmental parameters used in guidelines and analysis methods that can determine relations and interactions. The outcome is used to improve and detail the previous introduced approach.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 55 条
[1]  
Adan OCG, 2011, FUNDAMENTALS OF MOLD GROWTH IN INDOOR ENVIRONMENTS AND STRATEGIES FOR HEALTHY LIVING, P1, DOI 10.3921/978-90-8686-722-6
[2]  
[Anonymous], 2002, OLF TAST COGN
[3]  
Aries M, 2009, HERON, V54, P49
[4]  
ASHRAE, 2010, 222010 ASHRAE
[5]   Road traffic noise and cardiovascular risk [J].
Babisch, Wolfgang .
NOISE & HEALTH, 2008, 10 (38) :27-33
[6]   Relationships between occupant personality and the sick building syndrome explored [J].
Berglund, B ;
Gunnarsson, AG .
INDOOR AIR, 2000, 10 (03) :152-169
[7]   Self-reported health and comfort in "modern' office buildings: first results from the European OFFICAIR study [J].
Bluyssen, P. M. ;
Roda, C. ;
Mandin, C. ;
Fossati, S. ;
Carrer, P. ;
de Kluizenaar, Y. ;
Mihucz, V. G. ;
Fernandes, E. de Oliveira ;
Bartzis, J. .
INDOOR AIR, 2016, 26 (02) :298-317
[8]  
Bluyssen P. M., 2014, HLTH INDOOR ENV ASSE
[9]  
Bluyssen P. M., 2019, 1 SENSELAB STUDIES P
[10]  
Bluyssen P. M., 2017, P HLTH BUILD 2017 EU