The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff

被引:21
作者
De Carli, Angelo [1 ]
Lanzetti, Riccardo Maria [1 ]
Monaco, Edoardo [1 ]
Labianca, Luca [1 ]
Mossa, Luigi [1 ]
Feretti, Andrea [1 ]
机构
[1] Univ Roma La Sapienza, St Andrea Hosp, Orthopaed Unit, I-00189 Rome, Italy
关键词
ARTHROSCOPIC SINGLE-ROW; SUTURE-ANCHOR REPAIR; BIOMECHANICAL EVALUATION; FOOTPRINT; TENDON; TEARS; INTEGRITY; SUPRASPINATUS; ABDUCTION; CONTACT;
D O I
10.1007/s00776-012-0275-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.
引用
收藏
页码:789 / 795
页数:7
相关论文
共 33 条
[1]   Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation - Minimum 2-year follow-up [J].
Anderson, Kyle ;
Boothby, Michael ;
Aschenbrener, Daniel ;
van Holsbeeck, Marnix .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (12) :1899-1905
[2]   Rotator cuff tears:: The effect of the reconstruction method on three-dimensional repair site area [J].
Apreleva, M ;
Özbaydar, M ;
Fitzgibbons, PG ;
Warner, JJP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (05) :519-526
[3]   Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques [J].
Baleani, M ;
Schrader, S ;
Veronesi, CA ;
Rotini, R ;
Giardino, R ;
Toni, A .
CLINICAL BIOMECHANICS, 2003, 18 (08) :721-729
[4]   Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study [J].
Bishop, Julie ;
Klepps, Steven ;
Lo, Ian K. ;
Bird, Justin ;
Gladstone, James N. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) :290-299
[5]   Influence of suture material on the biomechanical behavior of suture-tendon specimens - A controlled study in bovine rotator cuff [J].
Bisson, Leslie J. ;
Manohar, Leslie M. ;
Wilkins, Ryan D. ;
Gurske-Deperio, Jennifer ;
Ehrensberger, Mark T. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (05) :907-912
[6]   Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[7]   THE DEADMAN THEORY OF SUTURE ANCHORS - OBSERVATIONS ALONG A SOUTH TEXAS FENCE LINE [J].
BURKHART, SS .
ARTHROSCOPY, 1995, 11 (01) :119-123
[8]   Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations [J].
Cole, Brian J. ;
ElAttrache, Neal S. ;
Anbari, Ammar .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :662-669
[9]   The Insertional footprint of the rotator cuff: An anatomic study [J].
Curtis, AS ;
Burbank, KM ;
Tierney, JJ ;
Scheller, AD ;
Curran, AR .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (06) :603-609
[10]   Effect of cyclic loading on new polyblend suture coupled with different anchors [J].
De Carli, A ;
Vadalà, A ;
Monaco, E ;
Labianca, L ;
Zanzotto, E ;
Ferretti, A .