Radiation exposure from medical imaging in dialyzed patients undergoing renal pre-transplant evaluation

被引:7
作者
De Mauri, Andreana [1 ]
Matheoud, Roberta [2 ]
Carriero, Alessandro [3 ]
Lizio, Domenico [2 ]
Chiarinotti, Doriana [1 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nephrol, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
Cumulative effective dose; Hemodialysis; Ionizing radiation exposure; Renal pre-transplant evaluation; IONIZING-RADIATION; CANCER; RISK; DIALYSIS;
D O I
10.1007/s40620-016-0275-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and aim Ionizing radiation exposure from medical procedures is rising sharply-the per-capita annual effective dose in the US is 3.0 millisieverts (mSv). Hemodialyzed and kidney transplanted patients receive still higher doses of ionizing radiation due to the presence of multiple comorbidities. The aim of this study was to assess the cumulative effective dose (CED) among dialyzed patients undergoing renal pre-transplant evaluation. Patients and methods We evaluated 70 hemodialysis patients between June 2009 and December 2014, aged 46.4 +/- 12.0 years. The number and type of radiologic procedures were collected through the Radiology Information System. CED was expressed as total mSv/patient and annual CED (mSv/patient/year). Results A total of 744 radiologic procedures were performed, accounting for 3869 mSv of ionizing radiation: conventional radiology, computed tomography and nuclear medicine accounted for 78, 14 and 8 % of the procedures, but they represented, respectively, 8, 83 and 9 % of the total CED. The mean (median) annual CED was 35 (7) mSv/patient/year, while total CED was 72 (32) mSv/patient. Thirty-seven patients were active waitlisted and received 47 (10) mSv during the pre-transplant evaluation and 36 (5) mSv during the waiting phase to maintain active status. Concerning cancer risk, 4 (7 %) patients were classified at low risk (< 3 mSv/year), 19 (35 %) at moderate risk (3 to < 20 mSv/year), 8 (15 %) at high risk (20 to < 50 mSv/year), and 23 (43 %) at very high risk (>= 50 mSv/year). Conclusions Our study demonstrated that during renal pre-transplant evaluation, dialyzed patients receive a high dose of ionizing radiation. Considering that transplanted individuals have a high incidence of cancer due to multifactorial etiology, it is mandatory to reduce the ionizing radiation imaging.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 31 条
[1]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[2]  
[Anonymous], 1998, Ann ICRP, V28, P1
[3]  
[Anonymous], 2005, RELATION DOSE EFFET
[4]  
[Anonymous], 2006, HLTH RISKS EXP LOW L
[5]   Estimated radiation risk of cancer from medical imaging in haemodialysis patients [J].
Brambilla, Marco ;
De Mauri, Andreana ;
Lizio, Domenico ;
Matheoud, Roberta ;
De Leo, Martino ;
Carriero, Alessandro .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 (09) :1680-1686
[6]   Cumulative radiation dose estimates from medical imaging in paediatric patients with non-oncologic chronic illnesses. A systematic review [J].
Brambilla, Marco ;
De Mauri, Andreana ;
Lizio, Domenico ;
Leva, Lucia ;
Carriero, Alessandro ;
Carpeggiani, Clara ;
Picano, Eugenio .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04) :403-412
[7]   Cumulative Radiation Dose from Medical Imaging in Chronic Adult Patients [J].
Brambilla, Marco ;
De Mauri, Andreana ;
Leva, Lucia ;
Carriero, Alessandro ;
Picano, Eugenio .
AMERICAN JOURNAL OF MEDICINE, 2013, 126 (06) :480-486
[8]  
Committee to assess health risks from exposure to low levels of ionizing radiation National Research Council, 2005, HLTH RISK EXP LOW LE
[9]   Cumulative ionizing radiation exposure in patients with end stage kidney disease: a 6-year retrospective analysis [J].
Coyle, Joe ;
Kinsella, Sinead ;
McCarthy, Siobhain ;
MacWilliams, Sebastian ;
McLaughlin, Patrick ;
Eustace, Joseph ;
Maher, Michael M. .
ABDOMINAL IMAGING, 2012, 37 (04) :632-638
[10]   Cumulative radiation dose from medical imaging in kidney transplant patients [J].
De Mauri, Andreana ;
Brambilla, Marco ;
Izzo, Cristina ;
Matheoud, Roberta ;
Chiarinotti, Doriana ;
Carriero, Alessandro ;
Stratta, Piero ;
De Leo, Martino .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (09) :3645-3651