Obstacles delaying the prompt deployment of piston-type mechanical cardiopulmonary resuscitation devices during emergency department resuscitation: A video-recording and time-motion study

被引:15
作者
Huang, Edward Pei-Chuan [1 ,2 ]
Wang, Hui-Chih [1 ]
Koa, Patrick Chow-In [1 ,3 ]
Chang, Anna Marie [4 ]
Fu, Chia-Ming [1 ]
Chen, Jiun-Wei [1 ]
Liao, Yen-Chen [1 ]
Liu, Hung-Chieh [1 ]
Fang, Yao-De [1 ]
Yang, Chih-Wei [1 ,3 ,5 ]
Chiang, Wen-Chu [1 ,3 ]
Ma, Matthew Huei-Ming [1 ,3 ]
Chen, Shyr-Chyr [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Emergency Med, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Inst Hlth Policy & Management, Coll Publ Hlth, Taipei 10764, Taiwan
[3] Natl Taiwan Univ, Inst Epidemiol & Prevent Med, Coll Publ Hlth, Taipei 10764, Taiwan
[4] Oregon Hlth & Sci Univ, Dept Emergency Med, Portland, OR 97239 USA
[5] Natl Taiwan Univ Hosp, Dept Med Educ, Taipei 100, Taiwan
关键词
Mechanical devices; Cardiopulmonary resuscitation (CPR); Video-recording; Time-motion analysis; No-flow time; Quality; HOSPITAL CARDIAC-ARREST; CHEST-COMPRESSION DEVICES; RESCUER FATIGUE; BLOOD-FLOW; QUALITY; PERFORMANCE; GUIDELINES;
D O I
10.1016/j.resuscitation.2013.03.028
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The quality of cardiopulmonary resuscitation (CPR) is important to survival after cardiac arrest. Mechanical devices (MD) provide constant CPR, but their effectiveness may be affected by deployment timeliness. Objectives: To identify the timeliness of the overall and of each essential step in the deployment of a piston-type MD during emergency department (ED) resuscitation, and to identify factors associated with delayed MD deployment by video recordings. Methods: Between December 2005 and December 2008, video clips from resuscitations with CPR sessions using a MD in the ED were reviewed using time-motion analyses. The overall deployment timeliness and the time spent on each essential step of deployment were measured. Results: There were 37 CPR recordings that used a MD. Deployment of MD took an average 122.6 +/- 57.8 s. The 3 most time-consuming steps were: (1) setting the device (57.8 +/- 38.3 s), (2) positioning the patient (33.4 +/- 38.0 s), and (3) positioning the device (14.7 +/- 9.5 s). Total no flow time was 89.1 +/- 41.2 s (72.7% of total time) and associated with the 3 most time-consuming steps. There was no difference in the total timeliness, no-flow time, and no-flow ratio between different rescuer numbers, time of day of the resuscitation, or body size of patients. Conclusions: Rescuers spent a significant amount of time on MD deployment, leading to long no-flow times. Lack of familiarity with the device and positioning strategy were associated with poor performance. Additional training in device deployment strategies are required to improve the benefits of mechanical CPR. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1208 / 1213
页数:6
相关论文
共 27 条
[1]   CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system [J].
Abella, Benjamin S. ;
Edelson, Dana P. ;
Kim, Salem ;
Retzer, Elizabeth ;
Myklebust, Helge ;
Barry, Anne M. ;
O'Hearn, Nicholas ;
Hoek, Terry L. Vanden ;
Becker, Lance B. .
RESUSCITATION, 2007, 73 (01) :54-61
[2]   Chest compression rates during cardiopulmonary resuscitation are suboptimal - A prospective study during in-hospital cardiac arrest [J].
Abella, BS ;
Sandbo, N ;
Vassilatos, P ;
Alvarado, JP ;
O'Hearn, N ;
Wigder, HN ;
Hoffman, P ;
Tynus, K ;
Vanden Hoek, TL ;
Becker, LB .
CIRCULATION, 2005, 111 (04) :428-434
[3]  
[Anonymous], CIRCULATION
[4]   Effect of rescuer fatigue on performance of continuous external chest compressions over 3 min [J].
Ashton, A ;
McCluskey, A ;
Gwinnutt, CL ;
Keenan, AM .
RESUSCITATION, 2002, 55 (02) :151-155
[5]   Poor chest compression quality with mechanical compressions in simulated cardiopulmonary resuscitation: A randomized, cross-over manikin study [J].
Blomberg, Hans ;
Gedeborg, Rolf ;
Berglund, Lars ;
Karlsten, Rolf ;
Johansson, Jakob .
RESUSCITATION, 2011, 82 (10) :1332-1337
[6]   Better adherence to the guidelines during cardiopulmonary resuscitation through the provision of audio-prompts [J].
Chiang, WC ;
Chen, WJ ;
Chen, SY ;
Ko, PCI ;
Lin, CH ;
Tsai, MS ;
Chang, WT ;
Chen, SC ;
Tsan, CY ;
Ma, MHM .
RESUSCITATION, 2005, 64 (03) :297-301
[7]   A comparison of manikin CPR performance by lay persons trained in three variations of basic life support guidelines [J].
Donnelly, P ;
Assar, D ;
Lester, C .
RESUSCITATION, 2000, 45 (03) :195-199
[8]   Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest - A randomized trial [J].
Hallstrom, Al ;
Rea, Thomas D. ;
Sayre, Michael R. ;
Christenson, James ;
Anton, Andy R. ;
Mosesso, Vince N., Jr. ;
Van Ottingham, Lois ;
Olsufka, Michele ;
Pennington, Sarah ;
White, Lynn J. ;
Yahn, Stephen ;
Husar, James ;
Morris, Mary F. ;
Cobb, Leonard A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22) :2620-2628
[9]   DECAY IN QUALITY OF CLOSED-CHEST COMPRESSIONS OVER TIME [J].
HIGHTOWER, D ;
THOMAS, SH ;
STONE, CK ;
DUNN, K ;
MARCH, JA .
ANNALS OF EMERGENCY MEDICINE, 1995, 26 (03) :300-303
[10]   Skeletal chest injuries secondary to cardiopulmonary resuscitation [J].
Hoke, RS ;
Chamberlain, D .
RESUSCITATION, 2004, 63 (03) :327-338