Diagnostic Workup and Costs of a Single Supplemental Molecular Breast Imaging Screen of Mammographically Dense Breasts

被引:37
作者
Hruska, Carrie B. [1 ]
Conners, Amy Lynn [1 ]
Jones, Katie N. [1 ]
O'Connor, Michael K. [1 ]
Moriarty, James P. [2 ]
Boughey, Judy C. [3 ]
Rhodes, Deborah J. [4 ]
机构
[1] Mayo Clin Rochester, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin Rochester, Ctr Sci Hlth Care Delivery, Rochester, MN 55905 USA
[3] Mayo Clin Rochester, Dept Surg, Rochester, MN 55905 USA
[4] Mayo Clin Rochester, Dept Med, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
benign biopsy rate; breast density; costs; molecular breast imaging; supplemental screening; POSITRON EMISSION MAMMOGRAPHY; PROBABLY BENIGN; GAMMA-CAMERA; MUTATION CARRIERS; CANCER-DETECTION; WOMEN; ULTRASOUND; LESIONS; RISK; MRI;
D O I
10.2214/AJR.14.13306
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to examine additional diagnostic workup and costs generated by addition of a single molecular breast imaging (MBI) examination to screening mammography for women with dense breasts. SUBJECTS AND METHODS. Women with mammographically dense breasts presenting for screening mammography underwent adjunct MBI performed with 300 MBq Tc-99m-sestamibi and a direct-conversion cadmium-zinc-telluride dual-head gamma camera. All subsequent imaging tests and biopsies were tracked for a minimum of 1 year. The positive predictive value of biopsies performed (PPV3), benign biopsy rate, cost per patient screened, and cost per cancer detected were determined. RESULTS. A total of 1651 women enrolled in the study. Among the 1585 participants with complete reference standard, screening mammography alone prompted diagnostic workup of 175 (11.0%) patients and biopsy of 20 (1.3%) and yielded five malignancies (PPV3, 25%). Results of combined screening mammography plus MBI prompted diagnostic workup of 279 patients (17.6%) and biopsy of 67 (4.2%) and yielded 19 malignancies (PPV3, 28.4%). The benign biopsy rates were 0.9% (15 of 1585) for screening mammography alone and 3.0% (48 of 1585) for the combination (p < 0.001). The addition of MBI increased the cost per patient screened from $176 for mammography alone to $571 for the combination. However, cost per cancer detected was lower for the combination ($47,597) than for mammography alone ($55,851). CONCLUSION. The addition of MBI to screening mammography of women with dense breasts increased the overall costs and benign biopsy rate but also increased the cancer detection rate, which resulted in a lower cost per cancer detected than with screening mammography alone.
引用
收藏
页码:1345 / 1353
页数:9
相关论文
共 34 条
  • [1] Probably Benign Lesions at Screening Breast US in a Population with Elevated Risk: Prevalence and Rate of Malignancy in the ACRIN 6666 Trial
    Barr, Richard G.
    Zhang, Zheng
    Cormack, Jean B.
    Mendelson, Ellen B.
    Berg, Wendie A.
    [J]. RADIOLOGY, 2013, 269 (03) : 701 - 712
  • [2] High-resolution fluorodeoxyglucose positron emission tomography with compression ("positron emission mammography") is highly accurate in depicting primary breast cancer
    Berg, Wendie A.
    Weinberg, Irving N.
    Narayanan, Deepa
    Lobrano, Mary E.
    Ross, Eric
    Amodei, Laura
    Tafra, Lorraine
    Adler, Lee P.
    Uddo, Joseph
    Stein, William, III
    Levine, Edward A.
    [J]. BREAST JOURNAL, 2006, 12 (04) : 309 - 323
  • [3] Technologist-performed Handheld Screening Breast US Imaging: How Is It Performed and What Are the Outcomes to Date?
    Berg, Wendie A.
    Mendelson, Ellen B.
    [J]. RADIOLOGY, 2014, 272 (01) : 12 - 27
  • [4] Detection of Breast Cancer With Addition of Annual Screening Ultrasound or a Single Screening MRI to Mammography in Women With Elevated Breast Cancer Risk
    Berg, Wendie A.
    Zhang, Zheng
    Lehrer, Daniel
    Jong, Roberta A.
    Pisano, Etta D.
    Barr, Richard G.
    Boehm-Velez, Marcela
    Mahoney, Mary C.
    Evans, W. Phil, III
    Larsen, Linda H.
    Morton, Marilyn J.
    Mendelson, Ellen B.
    Farria, Dione M.
    Cormack, Jean B.
    Marques, Helga S.
    Adams, Amanda
    Yeh, Nolin M.
    Gabrielli, Glenna
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (13): : 1394 - 1404
  • [5] Comparative Effectiveness of Positron Emission Mammography and MRI in the Contralateral Breast of Women With Newly Diagnosed Breast Cancer
    Berg, Wendie A.
    Madsen, Kathleen S.
    Schilling, Kathy
    Tartar, Marie
    Pisano, Etta D.
    Larsen, Linda Hovanessian
    Narayanan, Deepa
    Kalinyak, Judith E.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 219 - 232
  • [6] Breast Cancer: Comparative Effectiveness of Positron Emission Mammography and MR Imaging in Presurgical Planning for the Ipsilateral Breast
    Berg, Wendie A.
    Madsen, Kathleen S.
    Schilling, Kathy
    Tartar, Marie
    Pisano, Etta D.
    Larsen, Linda Hovanessian
    Narayanan, Deepa
    Ozonoff, Al
    Miller, Joel P.
    Kalinyak, Judith E.
    [J]. RADIOLOGY, 2011, 258 (01) : 59 - 72
  • [7] Tailored Supplemental Screening for Breast Cancer: What Now and What Next?
    Berg, Wendie A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : 390 - 399
  • [8] Detection of Occult Foci of Breast Cancer Using Breast-Specific Gamma Imaging in Women with One Mammographic or Clinically Suspicious Breast Lesion
    Brem, Rachel F.
    Shahan, Cimmie
    Rapleyea, Jocelyn A.
    Donnelly, Colleen A.
    Rechtman, Lauren R.
    Kidwell, Alison B.
    Teal, Christine B.
    McSwain, Anita
    Torrente, Jessica
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (06) : 735 - 743
  • [9] Occult breast cancer: Scintimammography with high-resolution breast-specific gamma camera in women at high risk for breast cancer
    Brem, RF
    Rapelyea, JA
    Zisman, G
    Mohtashemi, K
    Raub, J
    Teal, CB
    Majewski, S
    Welch, BL
    [J]. RADIOLOGY, 2005, 237 (01) : 274 - 280
  • [10] Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study
    Ciatto, Stefano
    Houssami, Nehmat
    Bernardi, Daniela
    Caumo, Francesca
    Pellegrini, Marco
    Brunelli, Silvia
    Tuttobene, Paola
    Bricolo, Paola
    Fanto, Carmine
    Valentini, Marvi
    Montemezzi, Stefania
    Macaskill, Petra
    [J]. LANCET ONCOLOGY, 2013, 14 (07) : 583 - 589