Osmolarity of basal and reflex tears of normal dogs

被引:13
作者
Lamkin, Irini D. [1 ]
Zimmerman, Kelli L. [1 ]
Smith Fleming, Kathryn M. [1 ]
Martins, Bianca C. [1 ]
机构
[1] Univ Illinois, Coll Vet Med, Dept Vet Clin Med, Urbana, IL USA
关键词
basal tears; dog; I-PEN(R) VET; osmolarity; reflex tears; tear film; DRY EYE DISEASE; FILM OSMOLARITY; KERATOCONJUNCTIVITIS SICCA; FERNING TEST; AGE; HYPEROSMOLARITY; GENDER; HORSES; FLUID; TIME;
D O I
10.1111/vop.12798
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective: To compare basal and reflex tear osmolarity in healthy dogs and to evaluate for correlation among tear film osmolarity, tear production, and tear fern pattern. Animals studied The population consisted of 22 healthy adult dogs. Procedures: Reflex tear osmolarity was measured in both eyes using the I-PEN(R) VET osmometer 30 minutes following the Schirmer tear test (STT-1) measurement. Subsequently, two minutes following topical anesthetic application, the lacrimal lake and conjunctival fornices were dried, and 3 minutes later, basal tear osmolarity was measured. Tears were extracted from the dye-free STT-1 strip by centrifugation, placed on a glass slide, and the ferning pattern was determined by light microscopy. Comparisons between basal and reflex tears were performed with one-way ANOVA. Correlations between tear osmolarity, STT-1, and tear ferning were verified by Pearson's correlation coefficient. Results: No statistical difference was found between right and left eyes for STT-1, tear fern pattern, and osmolarity of reflex or basal tears (P < .05). There was no statistical difference between osmolarity of basal and reflex tears among individuals (P < .05). No correlation was detected between tear fern pattern and osmolarity of reflex tears. A weak positive correlation was detected between STT-1 values and osmolarity of reflex, but not basal tears. Conclusions: The osmolarity of basal tears did not differ from that of reflex tears. A positive weak correlation exists between tear production and osmolarity of reflex tears. No correlation was detected between tear osmolarity measured by handheld osmometer and tear ferning.
引用
收藏
页码:747 / 753
页数:7
相关论文
共 58 条
[1]   Analysis of basal and reflex human tear osmolarity in normal subjects: assessment of tear osmolarity [J].
Abusharha, Ali A. ;
AlShehri, Tariq M. ;
Hakami, Abdullah Y. ;
Alsaqr, Ali M. ;
Fagehi, Raied A. ;
Alanazi, Saud A. ;
Masmali, Ali M. .
THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2018, 10
[2]  
[Anonymous], 2017, TEARLAB OSM SYST US
[3]  
[Anonymous], 2018, I PEN OSM SYST US MA
[4]  
Basha FYS, 2018, DRUG INVENT TODAY, V10, P1550
[5]   Schirmer tear test results in normal horses and ponies: effect of age, season, environment, sex, time of day and placement of strips [J].
Beech, J ;
Zappala, RA ;
Smith, G ;
Lindborg, S .
VETERINARY OPHTHALMOLOGY, 2003, 6 (03) :251-254
[6]   The fluctuation of tear production in the dog [J].
Berger, SL ;
King, VL .
JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1998, 34 (01) :79-83
[7]   Tear production in normal juvenile dogs [J].
Broadwater, Joshua J. ;
Colitz, Carmen ;
Carastro, Susan ;
Saville, William .
VETERINARY OPHTHALMOLOGY, 2010, 13 (05) :321-325
[8]   TFOS DEWS II pathophysiology report [J].
Bron, Anthony J. ;
de Paiva, Cintia S. ;
Chauhan, Sunil K. ;
Bonini, Stefano ;
Gabison, Eric E. ;
Jain, Sandeep ;
Knop, Erich ;
Markoulli, Maria ;
Ogawa, Yoko ;
Perez, Victor ;
Uchino, Yuichi ;
Yokoi, Norihiko ;
Zoukhri, Driss ;
Sullivan, David A. .
OCULAR SURFACE, 2017, 15 (03) :438-510
[9]   Tear Osmolarity in Sjogren Syndrome [J].
Bunya, Vatinee Y. ;
Langelier, Nicole ;
Chen, Sarah ;
Pistilli, Maxwell ;
Vivino, Frederick B. ;
Massaro-Giordano, Giacomina .
CORNEA, 2013, 32 (07) :922-927
[10]   Tear volume, turnover rate, and flow rate in ophthalmologically normal horses [J].
Chen, Thomas ;
Ward, Daniel A. .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2010, 71 (06) :671-676