Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system

被引:10
|
作者
Hu, Jun [1 ]
Kang, Yanming [1 ]
Lu, Yihang [1 ]
Yu, Jia [2 ]
Li, He [3 ]
Zhong, Ke [1 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Shanghai 201620, Peoples R China
[2] Yangzhou Univ, Sch Elect Energy & Power Engn, Yangzhou 225100, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Impinging jet ventilation; Passive chilled beam; Combined system; Ventilation performance; Thermal length scale; ENERGY-CONSUMPTION; DISPLACEMENT VENTILATION; MIXING VENTILATION; OFFICE; PREDICTION; BEHAVIOR; COMFORT; ROOMS; FLOW;
D O I
10.1016/j.buildenv.2022.109726
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Impinging jet ventilation (IJV) systems provide high ventilation efficiency and good indoor air quality (IAQ) in the cooling mode. However, they have a limited cooling capacity. Passive chilled beam (PCB) systems are widely used in indoor environments with high cooling loads and can potentially address the limitation of low cooling capacity of IJV. In this study, the possibility of combining IJV and PCB systems is investigated using computa-tional fluid dynamics (CFD) simulations. The effects of two main factors, namely the percentage of cooling load removed by the PCB system (eta) and supply air parameters (Lm) of the IJV system, on the thermal and ventilation performance of the IJV-PCB system are examined. The results indicate that the PCB system enhances the mixing of indoor air and effectively reduces the vertical temperature gradient in the IJV room. An optimal range of eta that improves the cooling capacity and maintains the high ventilation performance of IJV is determined. This range for an IJV-PCB system is 0.15 < eta < 0.45, considering thermal comfort, IAQ, and energy saving potential. In addition, the IJV-PCB system offers a wide selection range for Lm (0.4-1.2) compared with that of the IJV, and a high ventilation efficiency and good IAQ are maintained in the room in this range.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Numerical Analysis on the Thermal Performance in an Excavating Roadway with Auxiliary Ventilation System
    Li, Zijun
    Liu, Huasen
    Xu, Yu
    Li, Rongrong
    Jia, Mintao
    Zhang, Mengsheng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) : 1 - 17
  • [42] NUMERICAL STUDY ON THERMAL INDOOR ENVIRONMENT OF AN OFFICE WITH HYBRID SYSTEM OF CHILLED CEILING PANEL AND DISPLACEMENT VENTILATION
    Zhao, Lei
    Feng, Yannan
    Yuan, Feng
    Zhang, Peidong
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 547 - 552
  • [43] Influence of the ventilation system on thermal comfort of the chilled panel system in heating mode
    Tian, Zhe
    Ding, Yan
    Wang, Shuo
    Yin, Xinglei
    Wang, Menglei
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2360 - 2364
  • [44] THERMAL PERFORMANCE OF A NATURAL VENTILATION SYSTEM
    Jimenez, M. J.
    Guzman, J. D.
    Heras, M. R.
    Arce, J.
    Xaman, J. P.
    Alvarez, G.
    ES2010: PROCEEDINGS OF ASME 4TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2010, : 329 - 336
  • [45] A numerical investigation of combined solar chimney and water wall for building ventilation and thermal comfort
    Wang, Haoyu
    Lei, Chengwang
    BUILDING AND ENVIRONMENT, 2020, 171
  • [46] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    ENERGY AND BUILDINGS, 2021, 235
  • [47] Investigation of Thermal Comfort in a Space Conditioned by Liquid Desiccant Membrane Chilled Ceiling/Displacement Ventilation System
    Seblany, Racha
    Ghaddar, Nesreen
    Ghali, Kamel
    Ismail, Nagham
    Simonetti, Marco
    Vincenzo, Fracastoro Giovanni
    Virgone, Joseph
    Zoughaib, Assaad
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 85 - 94
  • [48] Evaluation of thermal comfort, IAQ and energy consumption in an impinging jet ventilation (IJV) system with/without ceiling exhaust
    Haghshenaskashani, Samira
    Sajadi, Behrang
    JOURNAL OF BUILDING ENGINEERING, 2018, 18 : 142 - 153
  • [49] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    Energy and Buildings, 2021, 235
  • [50] Effect of active chilled beam layouts on ventilation performance and thermal comfort under variable heat gain conditions
    Ming, Ru
    Mustakallio, Panu
    Kosonen, Risto
    Kaukola, Tuomas
    Kilpelainen, Simo
    Li, Baizhan
    Wu, Yuxin
    Yao, Runming
    BUILDING AND ENVIRONMENT, 2023, 228