Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system

被引:10
|
作者
Hu, Jun [1 ]
Kang, Yanming [1 ]
Lu, Yihang [1 ]
Yu, Jia [2 ]
Li, He [3 ]
Zhong, Ke [1 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Shanghai 201620, Peoples R China
[2] Yangzhou Univ, Sch Elect Energy & Power Engn, Yangzhou 225100, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Impinging jet ventilation; Passive chilled beam; Combined system; Ventilation performance; Thermal length scale; ENERGY-CONSUMPTION; DISPLACEMENT VENTILATION; MIXING VENTILATION; OFFICE; PREDICTION; BEHAVIOR; COMFORT; ROOMS; FLOW;
D O I
10.1016/j.buildenv.2022.109726
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Impinging jet ventilation (IJV) systems provide high ventilation efficiency and good indoor air quality (IAQ) in the cooling mode. However, they have a limited cooling capacity. Passive chilled beam (PCB) systems are widely used in indoor environments with high cooling loads and can potentially address the limitation of low cooling capacity of IJV. In this study, the possibility of combining IJV and PCB systems is investigated using computa-tional fluid dynamics (CFD) simulations. The effects of two main factors, namely the percentage of cooling load removed by the PCB system (eta) and supply air parameters (Lm) of the IJV system, on the thermal and ventilation performance of the IJV-PCB system are examined. The results indicate that the PCB system enhances the mixing of indoor air and effectively reduces the vertical temperature gradient in the IJV room. An optimal range of eta that improves the cooling capacity and maintains the high ventilation performance of IJV is determined. This range for an IJV-PCB system is 0.15 < eta < 0.45, considering thermal comfort, IAQ, and energy saving potential. In addition, the IJV-PCB system offers a wide selection range for Lm (0.4-1.2) compared with that of the IJV, and a high ventilation efficiency and good IAQ are maintained in the room in this range.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Numerical investigation of passive ventilation in transonic internal flows
    Schnerr, GH
    Seguin, H
    Adam, S
    Magagnato, F
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1997, 77 : S305 - S306
  • [32] Assessment of Thermal Comfort and Air Quality of Room Conditions by Impinging Jet Ventilation Integrated with Ductless Personalized Ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Jin, Dacheng
    Wang, Faming
    SUSTAINABILITY, 2022, 14 (19)
  • [33] Experimental investigation into the thermal performance of a residential hybrid ventilation system
    Turner, William J. N.
    Awbi, Hazim B.
    APPLIED THERMAL ENGINEERING, 2015, 77 : 142 - 152
  • [34] Numerical comparison of the efficiency of mixing ventilation and impinging jet ventilation for exhaled particle removal in a model intensive care unit
    Wang, Lei
    Dai, Xiahong
    Wei, Jianjian
    Ai, Zhengtao
    Fan, Yifan
    Tang, Lingling
    Jin, Tao
    Ge, Jian
    BUILDING AND ENVIRONMENT, 2021, 200
  • [35] Geometric-parameter influence and orthogonal evaluation on the thermal environment for an impinging jet ventilation system inlet
    Wang, Chen
    Zhang, Xiaoying
    Hu, Ke
    Liu, Yin
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [36] Optimized selection and operation of the combined chilled ceiling system and displacement ventilation
    Ghaddar, N.
    Ghali, K.
    Saadeh, R.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (15) : 1328 - 1340
  • [37] Effect of supply velocity and heat generation density on cooling and ventilation effectiveness in room with impinging jet ventilation system
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Cehlin, Mathias
    Ameen, Arman
    BUILDING AND ENVIRONMENT, 2021, 205
  • [38] A numerical investigation into the effect of Windvent louvre external angle on passive stack ventilation performance
    Hughes, Ben Richard
    Ghani, S. A. A. Abdul
    BUILDING AND ENVIRONMENT, 2010, 45 (04) : 1025 - 1036
  • [39] Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling
    Lipczynska, Aleksandra
    Kaczmarczyk, Jan
    Melikov, Arsen K.
    BUILDING AND ENVIRONMENT, 2015, 92 : 603 - 614
  • [40] Indoor thermal environment in rooms with combined air conditioning system of displacement ventilation and chilled ceiling panel
    School of Muni. and Eviron. Eng., Xi'an Univ. of Arch. and Tech, Xi'an 710055, China
    Xi'an Jianzhu Keji Daxue Xuebao, 2007, 4 (558-562):