Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system

被引:10
|
作者
Hu, Jun [1 ]
Kang, Yanming [1 ]
Lu, Yihang [1 ]
Yu, Jia [2 ]
Li, He [3 ]
Zhong, Ke [1 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Shanghai 201620, Peoples R China
[2] Yangzhou Univ, Sch Elect Energy & Power Engn, Yangzhou 225100, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Impinging jet ventilation; Passive chilled beam; Combined system; Ventilation performance; Thermal length scale; ENERGY-CONSUMPTION; DISPLACEMENT VENTILATION; MIXING VENTILATION; OFFICE; PREDICTION; BEHAVIOR; COMFORT; ROOMS; FLOW;
D O I
10.1016/j.buildenv.2022.109726
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Impinging jet ventilation (IJV) systems provide high ventilation efficiency and good indoor air quality (IAQ) in the cooling mode. However, they have a limited cooling capacity. Passive chilled beam (PCB) systems are widely used in indoor environments with high cooling loads and can potentially address the limitation of low cooling capacity of IJV. In this study, the possibility of combining IJV and PCB systems is investigated using computa-tional fluid dynamics (CFD) simulations. The effects of two main factors, namely the percentage of cooling load removed by the PCB system (eta) and supply air parameters (Lm) of the IJV system, on the thermal and ventilation performance of the IJV-PCB system are examined. The results indicate that the PCB system enhances the mixing of indoor air and effectively reduces the vertical temperature gradient in the IJV room. An optimal range of eta that improves the cooling capacity and maintains the high ventilation performance of IJV is determined. This range for an IJV-PCB system is 0.15 < eta < 0.45, considering thermal comfort, IAQ, and energy saving potential. In addition, the IJV-PCB system offers a wide selection range for Lm (0.4-1.2) compared with that of the IJV, and a high ventilation efficiency and good IAQ are maintained in the room in this range.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental investigation of difference in indoor environment using impinging jet ventilation and displacement ventilation systems
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Matsuzaki, Mako
    INTERNATIONAL JOURNAL OF VENTILATION, 2022, 21 (03) : 229 - 246
  • [22] Prediction of thermal and contaminant environment in a room with impinging jet ventilation system by zonal model
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Cehlin, Mathias
    Ameen, Arman
    BUILDING AND ENVIRONMENT, 2022, 221
  • [23] Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads
    Chen, H. J.
    Moshfegh, B.
    Cehlin, M.
    BUILDING AND ENVIRONMENT, 2013, 59 : 127 - 144
  • [24] Numerical investigation of passive ventilation for cavitation control
    Wursthorn, S
    Schnerr, GH
    FOURTH INTERNATIONAL SYMPOSIUM ON EXPERIMENTAL AND COMPUTATIONAL AEROTHERMODYNAMICS OF INTERNAL FLOWS, VOL II, PROCEEDINGS, 1999, : 291 - 304
  • [25] Impact of impinging jet ventilation on thermal comfort and aerosol transmission: A numerical investigation in a densely-occupied classroom with solar effect
    Li, Xueren
    Chen, Ziqi
    Tu, Jiyuan
    Yu, Hang
    Tang, Yin
    Qin, Chao
    JOURNAL OF BUILDING ENGINEERING, 2024, 94
  • [26] Numerical investigation of transient buoyant flow in a room with a displacement ventilation and chilled ceiling system
    Rees, SJ
    McGuirk, JJ
    Haves, P
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (16) : 3067 - 3080
  • [27] A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification
    Hao, Xiaoli
    Zhang, Guoqiang
    Chen, Youming
    Zou, Shenghua
    Moschandreas, Demetrios. J.
    BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3298 - 3308
  • [28] Design Charts for Combined Chilled Ceiling Displacement Ventilation System
    Ghaddar, Nesreen
    Ghali, Kamel
    Saadeh, Ralph
    Keblawi, Amer
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 2, 2008, 114 : 574 - +
  • [29] Thermal and draught perception in fluctuating stratified thermal environments with intermittent impinging jet ventilation
    Zhou, Bin
    Li, Zhe
    Yang, Bin
    Li, Xiaojing
    Wang, Faming
    Wei, Shen
    BUILDING AND ENVIRONMENT, 2023, 229
  • [30] Simplified thermal model of spaces cooled with combined positive displacement ventilation and chilled ceiling system
    Ayoub, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    HVAC&R RESEARCH, 2006, 12 (04): : 1005 - 1030