Prolonged stability of stored vancomycin, gentamicin, and heparin for use in the antibiotic-lock technique

被引:8
作者
Bastani, B [1 ]
Amin, K [1 ]
Herr, A [1 ]
机构
[1] St Louis Univ, Sch Med, Dept Internal Med, Div Nephrol, St Louis, MO 63110 USA
关键词
D O I
10.1097/01.mat.0000183656.75618.09
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The antibiotic-lock technique has been effective in salvaging tunneled catheters in hemodialysis patients with bacteremia. However, a practical concern exists with respect to the stability of the antibiotics and heparin in normal saline, when stored for a prolonged period. Vancomycin, gentamicin, and heparin were diluted in normal saline to a final concentration of 100 mu g/ml of each antibiotic and 5000 units/ml heparin. Fresh samples, and samples refrigerated at VC for 48 hours, 1 week, 2 weeks, 3 weeks, and 4 weeks, were assayed (in triplicate) for gentamicin and vancomycin concentration and bactericidal activity (Schlichter test) using methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa. An anti-Xa activity assay was used for monitoring heparin anticoagulant activity of the fresh samples and samples refrigerated for 2 and 4 weeks. Mean (SD) anti-Xa activity for heparin/vancomycin solution was 7900 +/- 173 u/ml, and for heparin/gentamicin solution was 7467 +/- 751 u/ml; both were stable over a 4-week storage period. Mean bactericidal titer for vancomycin was 1:121 +/- 11, and for gentamicin was 1:242 +/- 22; both were stable over a 4-week storage period. Mean vancomycin concentration was 97 +/- 4 mu g/ml, and gentamicin concentration was 86 +/- 3 mu g/ml; both were stable over a 4-week storage period. Vancomycin and gentamicin in a heparin/saline solution can be stored at VC for up to 4 weeks without adversely affecting antibiotic concentration, bactericidal activity, or heparin anticoagulant activity.
引用
收藏
页码:761 / 763
页数:3
相关论文
共 21 条
[1]   Elimination of intraluminal colonization by antibiotic lock in silicone vascular catheters [J].
Andris, DA ;
Krzywda, EA ;
Edmiston, CE ;
Krepel, CJ ;
Gohr, CM .
NUTRITION, 1998, 14 (05) :427-432
[2]   Stability of antibiotics used for antibiotic-lock treatment of infections of implantable venous devices (Ports) [J].
Anthony, TU ;
Rubin, LG .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1999, 43 (08) :2074-2076
[3]   Insufficient penetration of systemic vancomycin into the PermCath lumen [J].
Bastani, B ;
Minton, J ;
Islam, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (07) :1035-1037
[4]   Adjunctive antibiotic/anticoagulant lock therapy in the treatment of bacteremia associated with the use of a subcutaneously implanted hemodialysis access device [J].
Boorgu, R ;
Dubrow, AJ ;
Levin, NW ;
My, H ;
Canaud, BJ ;
Lentino, JR ;
Wentworth, DW ;
Hatch, DA ;
Megerman, J ;
Prosl, FR ;
Gandhi, VC ;
Ing, TS .
ASAIO JOURNAL, 2000, 46 (06) :767-770
[5]  
CAPDEVILA JA, 1993, NEPHROL DIAL TRANSPL, V8, P231
[6]   Bacterial biofilms: A common cause of persistent infections [J].
Costerton, JW ;
Stewart, PS ;
Greenberg, EP .
SCIENCE, 1999, 284 (5418) :1318-1322
[7]  
Kovalik EC, 1996, J AM SOC NEPHROL, V7, P2264
[8]   Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution [J].
Krishnasami, Z ;
Carlton, D ;
Bimbo, L ;
Taylor, ME ;
Balkovetz, DF ;
Barker, J ;
Allon, M .
KIDNEY INTERNATIONAL, 2002, 61 (03) :1136-1142
[9]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+
[10]   Locking of tunneled hemodialysis catheters with gentamicin and heparin [J].
McIntyre, CW ;
Hulme, LJ ;
Taal, M ;
Fluck, RJ .
KIDNEY INTERNATIONAL, 2004, 66 (02) :801-805