Inter- and intraobserver agreement for gastroesophageal reflux detection in infants using multiple intraluminal impedance

被引:28
作者
Peter, CS
Sprodowski, N
Ahlborn, V
Wiechers, C
Schlaud, M
Silny, J
Poets, CF
机构
[1] Univ Tubingen, Dept Neonatol, DE-72076 Tubingen, Germany
[2] Hannover Med Sch, Dept Pediat Pulm & Neonatol, D-3000 Hannover, Germany
[3] Hannover Med Sch, Dept Epidemiol Social Med & Hlth Syst Res, D-3000 Hannover, Germany
[4] Rhein Westfal TH Aachen, Helmholtz Inst, Aachen, Germany
来源
BIOLOGY OF THE NEONATE | 2004年 / 85卷 / 01期
关键词
gastrointestinal motility; validation; observer agreement;
D O I
10.1159/000074951
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The multiple intraluminal impedance (MII) technique is a new method that allows pH-independent gastroesophageal reflux detection via changes in impedance caused by a liquid bolus inside the esophagus. We wanted to know whether this technique yields objective and reproducible results. Twenty 3- to 6-hour recordings of MII from 19 preterm infants ( median gestational age at birth 30 weeks, range 24 - 34 weeks; age at study 26 days, range 13 - 93 days) were divided into 23-second segments and analyzed for reflux episodes by three investigators; one investigator analyzed the data set twice. Observer agreement was assessed using kappa statistics. Each investigator analyzed 16,627 23-second segments, with a median of 854 ( range 486 - 979) segments per recording. Median kappa values for the 20 recordings were 0.79, 0.83, and 0.83 for the three pairs of investigators and 0.84 for the repeated scoring procedure. MII recordings could be analyzed with a high level of inter- and intraobserver agreement. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 12 条
[1]   Agreement among raters in assessment of physiologic waveforms recorded by a cardiorespiratory monitor for home use [J].
Corwin, MJ ;
Lister, G ;
Silvestri, JM ;
Peucker, M ;
Brooks, LJ ;
Ward, SLD ;
Hunt, CE ;
Neuman, MR ;
Crowell, DH ;
Colton, T .
PEDIATRIC RESEARCH, 1998, 44 (05) :682-690
[2]   MEASURING ESOPHAGEAL MOTILITY WITH A NEW INTRALUMINAL IMPEDANCE DEVICE - FIRST CLINICAL-RESULTS IN REFLUX PATIENTS [J].
FASS, J ;
SILNY, J ;
BRAUN, J ;
HEINDRICHS, U ;
DREUW, B ;
SCHUMPELICK, V ;
RAU, G .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1994, 29 (08) :693-702
[3]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[4]   Simultaneous monitoring of gastric and oesophageal pH reveals limitations of conventional oesophageal pH monitoring in milk fed infants [J].
Mitchell, DJ ;
McClure, BG ;
Tubman, TRJ .
ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 84 (03) :273-276
[5]   Dynamics of esophageal bolus transport in healthy subjects studied using multiple intraluminal impedancometry [J].
Nguyen, HN ;
Silny, J ;
Albers, D ;
Roeb, E ;
Gartung, C ;
Rau, G ;
Matern, S .
AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 1997, 273 (04) :G958-G964
[6]   Multiple intraluminal electrical impedancometry for recording of upper gastrointestinal motility: Current results and further implications [J].
Nguyen, HN ;
Silny, J ;
Matern, S .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 1999, 94 (02) :306-317
[7]   Gastroesophageal reflux and apnea of prematurity: No temporal relationship [J].
Peter, CS ;
Sprodowski, N ;
Bohnhorst, B ;
Silny, J ;
Poets, CF .
PEDIATRICS, 2002, 109 (01) :8-11
[8]   Patterns of gas and liquid reflux during transient lower oesophageal sphincter relaxation: a study using intraluminal electrical impedance [J].
Sifrim, D ;
Silny, J ;
Holloway, RH ;
Janssens, JJ .
GUT, 1999, 44 (01) :47-54
[9]   Gastroesophageal reflux in infants: Evaluation of a new intraluminal impedance technique [J].
Skopnik, H ;
Silny, J ;
Heiber, O ;
Schulz, J ;
Rau, G ;
Heimann, G .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1996, 23 (05) :591-598
[10]   Procedure for the semi-automatic detection of gastro-oesophageal reflux patterns in intraluminal impedance measurements in infants [J].
Trachterna, M ;
Wenzl, TG ;
Silny, J ;
Rau, G ;
Heimann, G .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (03) :195-201