Validation of automated Alberta Stroke Program Early CT Score (ASPECTS) software for detection of early ischemic changes on non-contrast brain CT scans

被引:13
作者
Wolff, Lennard [1 ]
Berkhemer, Olvert A. [1 ,2 ,3 ]
van Es, Adriaan C. G. M. [1 ]
van Zwam, Wim H. [4 ]
Dippel, Diederik W. J. [1 ,3 ]
Majoie, Charles B. L. M. [2 ]
van Walsum, Theo [1 ,5 ]
van der Lugt, Aad [1 ]
机构
[1] Erasmus MC, Dept Radiol & Nucl Med, P van Andel & L Wolff,Room Ne 515,Postbus 2040, NL-3000 CA Rotterdam, Netherlands
[2] Amsterdam Univ Med Ctr, Dept Radiol & Nucl Med, Locat AMC, Amsterdam, Netherlands
[3] Erasmus MC, Dept Neurol, Rotterdam, Netherlands
[4] Maastricht UMC, Dept Radiol, Maastricht, Netherlands
[5] Erasmus MC, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
关键词
Stroke; Tomography; X-Ray Computed; Brain ischemia; Image Processing; Computer-Assisted; Software validation; INTRAARTERIAL TREATMENT; COMPUTED-TOMOGRAPHY; RELIABILITY; PERFORMANCE; EFFICACY; SAFETY; TRIAL;
D O I
10.1007/s00234-020-02533-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose In ASPECTS, 10 brain regions are scored visually for presence of acute ischemic stroke damage. We evaluated automated ASPECTS in comparison to expert readers. Methods Consecutive, baseline non-contrast CT-scans (5-mm slice thickness) from the prospective MR CLEAN trial (n= 459, MR CLEAN Netherlands Trial Registry number: NTR1804) were evaluated. A two-observer consensus for ASPECTS regions (normal/abnormal) was used as reference standard for training and testing (0.2/0.8 division). Two other observers provided individual ASPECTS-region scores. The Automated ASPECTS software was applied. A region score specificity of >= 90% was used to determine the software threshold for detection of an affected region based on relative density difference between affected and contralateral region. Sensitivity, specificity, and receiver-operating characteristic curves were calculated. Additionally, we assessed intraclass correlation coefficients (ICCs) for automated ASPECTS and observers in comparison to the reference standard in the test set. Results In the training set (n= 104), with software thresholds for a specificity of >= 90%, we found a sensitivity of 33-49% and an area under the curve (AUC) of 0.741-0.785 for detection of an affected ASPECTS region. In the test set (n= 355), the results for the found software thresholds were 89-89% (specificity), 41-57% (sensitivity), and 0.750-0.795 (AUC). Comparison of automated ASPECTS with the reference standard resulted in an ICC of 0.526. Comparison of observers with the reference standard resulted in an ICC of 0.383-0.464. Conclusion The performance of automated ASPECTS is comparable to expert readers and could support readers in the detection of early ischemic changes.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 25 条
[1]   Automated Calculation of Alberta Stroke Program Early CT Score Validation in Patients With Large Hemispheric Infarct [J].
Albers, Gregory W. ;
Wald, Michael J. ;
Mlynash, Michael ;
Endres, Juergen ;
Bammer, Roland ;
Straka, Matus ;
Maier, Andreas ;
Hinson, Holly E. ;
Sheth, Kevin N. ;
Kimberly, W. Taylor ;
Molyneaux, Bradley J. .
STROKE, 2019, 50 (11) :3277-3279
[2]   Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapy [J].
Barber, PA ;
Demchuk, AM ;
Zhang, JJ ;
Buchan, AM .
LANCET, 2000, 355 (9216) :1670-1674
[3]   A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke [J].
Berkhemer, O. A. ;
Fransen, P. S. S. ;
Beumer, D. ;
van den Berg, L. A. ;
Lingsma, H. F. ;
Yoo, A. J. ;
Schonewille, W. J. ;
Vos, J. A. ;
Nederkoorn, P. J. ;
Wermer, M. J. H. ;
van Walderveen, M. A. A. ;
Staals, J. ;
Hofmeijer, J. ;
van Oostayen, J. A. ;
Nijeholt, G. J. Lycklama A. ;
Boiten, J. ;
Brouwer, P. A. ;
Emmer, B. J. ;
de Bruijn, S. F. ;
van Dijk, L. C. ;
Kappelle, L. J. ;
Lo, R. H. ;
Van Dijk, E. J. ;
de Vries, J. ;
de Kort, P. L. M. ;
van Rooij, W. J. J. ;
van den Berg, J. S. P. ;
van Hasselt, B. A. A. M. ;
Aerden, L. A. M. ;
Dallinga, R. J. ;
Visser, M. C. ;
Bot, J. C. J. ;
Vroomen, P. C. ;
Eshghi, O. ;
Schreuder, T. H. C. M. L. ;
Heijboer, R. J. J. ;
Keizer, K. ;
Tielbeek, A. V. ;
den Hertog, H. M. ;
Gerrits, D. G. ;
van den Berg-Vos, R. M. ;
Karas, G. B. ;
Steyerberg, E. W. ;
Flach, H. Z. ;
Marquering, H. A. ;
Sprengers, M. E. S. ;
Jenniskens, S. F. M. ;
Beenen, L. F. M. ;
van den Berg, R. ;
Koudstaal, P. J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (01) :11-20
[4]   Early CT changes in patients admitted for thrombectomy Intrarater and interrater agreement [J].
Farzin, Behzad ;
Fahed, Robert ;
Guilbert, Francois ;
Poppe, Alexandre Y. ;
Daneault, Nicole ;
Durocher, Andre P. ;
Lanthier, Sylvain ;
Boudjani, Hayet ;
Khoury, Naim N. ;
Roy, Daniel ;
Weill, Alain ;
Gentric, Jean-Christophe ;
Batista, Andre L. ;
Letourneau-Guillon, Laurent ;
Bergeron, Francois ;
Henry, Marc-Antoine ;
Darsaut, Tim E. ;
Raymond, Jean .
NEUROLOGY, 2016, 87 (03) :249-256
[5]   MR CLEAN, a multicenter randomized clinical trial of endovascular treatment for acute ischemic stroke in the Netherlands: study protocol for a randomized controlled trial [J].
Fransen, Puck S. S. ;
Beumer, Debbie ;
Berkhemer, Olvert A. ;
van den Berg, Lucie A. ;
Lingsma, Hester ;
van der Lugt, Aad ;
van Zwam, Wim H. ;
van Oostenbrugge, Robert J. ;
Roos, Yvo B. W. E. M. ;
Majoie, Charles B. ;
Dippel, Diederik W. J. .
TRIALS, 2014, 15
[6]   Automated ASPECT rating: comparison between the Frontier ASPECT Score software and the Brainomix software [J].
Goebel, Juliane ;
Stenzel, Elena ;
Guberina, Nika ;
Wanke, Isabel ;
Koehrmann, Martin ;
Kleinschnitz, Christoph ;
Umutlu, Lale ;
Forsting, Michael ;
Moenninghoff, Christoph ;
Radbruch, Alexander .
NEURORADIOLOGY, 2018, 60 (12) :1267-1272
[7]   Detection of early infarction signs with machine learning-based diagnosis by means of the Alberta Stroke Program Early CT score (ASPECTS) in the clinical routine [J].
Guberina, Nika ;
Dietrich, U. ;
Radbruch, A. ;
Goebel, J. ;
Deuschl, C. ;
Ringelstein, A. ;
Koehrmann, M. ;
Kleinschnitz, C. ;
Forsting, M. ;
Moenninghoff, C. .
NEURORADIOLOGY, 2018, 60 (09) :889-901
[8]   Interobserver Reliability of Baseline Noncontrast CT Alberta Stroke Program Early CT Score for Intra-Arterial Stroke Treatment Selection [J].
Gupta, A. C. ;
Schaefer, P. W. ;
Chaudhry, Z. A. ;
Leslie-Mazwi, T. M. ;
Chandra, R. V. ;
Gonzalez, R. G. ;
Hirsch, J. A. ;
Yoo, A. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1046-1049
[9]  
Hampton-Till J, 2015, EUR MED J
[10]   Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients [J].
Herweh, Christian ;
Ringleb, Peter A. ;
Rauch, Geraldine ;
Gerry, Steven ;
Behrens, Lars ;
Moehlenbruch, Markus ;
Gottorf, Rebecca ;
Richter, Daniel ;
Schieber, Simon ;
Nagel, Simon .