A New Method for On-Line Monitoring of Bushings and Partial Discharges of Power Transformers

被引:0
|
作者
Koch, Maik [1 ]
Krueger, Michael [2 ]
机构
[1] Omicron Energy Solut, Berlin, Germany
[2] Omicron Electron, \ klaus, Austria
来源
PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012) | 2012年
关键词
power transformers; on-line monitoring; bushings; dissipation factor; capacitance; partial discharges; UHF;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. Failure statistics identify HV bushings as one of the major reasons for transformer failure, which motivates operators for continuous on-line monitoring of their insulation systems health. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1% for dissipation factor. For rearching this goal, a relative comparison of the bushing currents of the three phases, measured at the bushing taps, does not provide sufficient accuracy due to imbalances in the network. Additionally, simultaneous ageing, as it can be anticipated for a three phase transformer, will not be detected. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and sissipation factor of HV bushings. Even under field conditions a measurement accuracy similar to accurate off-line power factor tests was reached. Partial discharges are an early breakdown indicator for HV dielectrics. With the measurement on the HV bushing tap, not only failure of the bushings dielectric but also of the transformer insulation system can be detected. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
引用
收藏
页码:1205 / 1208
页数:4
相关论文
共 50 条
  • [21] On-line three-phase differential partial discharge localization in transformer bushings
    Meyer, Hans Kristian Hygen
    Eberg, Espen
    Lundgaard, Lars
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 80 - 83
  • [22] Field practices of UHF technique for on-line PD monitoring and site testing of power transformers
    Tang, ZG
    Li, CR
    Huang, XQ
    Wang, W
    Ding, YS
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 1176 - 1182
  • [23] On-line Monitoring Method for Transformer Bushings with Moisture Based on Air Humidity Perception in Conservator
    Jia L.
    Wang T.
    Xiao W.
    Shu S.
    Li W.
    Zheng Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (09): : 3114 - 3123
  • [24] Priority assessment model of on-line monitoring devices investment for power transformers
    Liang, Yongliang
    Lin, Zhuoran
    Li, Ke-Jun
    Niu, Lin
    Zhao, Jianguo
    Lee, Wei-Jen
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2018, 35 (01) : 589 - 599
  • [25] A correlation method for detection of partial discharges in transformers
    Jayalalitha, S
    Jayashankar, V
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) : 531 - 532
  • [26] On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer
    林渡
    姜磊
    李福祺
    朱德恒
    谈克雄
    吴成琦
    金显贺
    王昌长
    郑振中
    Tsinghua Science and Technology, 2005, (05) : 598 - 604
  • [27] Adapting frequency domain spectroscopy as an on-line monitoring tool for the insulation of power transformers
    Jaya, Michael
    Rink, Yannick
    Leibfried, Thomas
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 501 - 504
  • [28] Robust Measurement, Monitoring and Analysis of Partial Discharges in Transformers and other HV Apparatus
    Kraetge, Alexander
    Hoek, Stefan
    Koch, Maik
    Koltunowicz, Wojciech
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2043 - 2051
  • [29] Noise rejection techniques used for on-line monitoring of partial discharges in large turbine generators
    Jiang, XW
    Zhang, XH
    Jia, ZD
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 157 - 160
  • [30] LOCATION OF PARTIAL DISCHARGE SITES IN ON-LINE TRANSFORMERS.
    Howells, E.
    Norton, E.T.
    Proceedings of the Annual Reliability and Maintainability Symposium, 1980,