Damping Torque Analysis of the PMSG-Based WT with Supplementary Damping Control for Mitigating Interarea Oscillations

被引:0
作者
Yang, Yanan [1 ]
Li, Yujun [1 ]
Yuan, Xiaotian [1 ,2 ]
Li, Jiapeng [1 ]
Du, Zhengchun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710000, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
基金
中国国家自然科学基金;
关键词
LOW-FREQUENCY OSCILLATIONS; DFIG WIND TURBINES; POWER OSCILLATIONS; DESIGN; IMPACT; AREA; PENETRATION; SYSTEMS; HVDC;
D O I
10.1155/2022/2391770
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents a comprehensive analysis of the impact that a supplementary damping controller of the permanent magnet synchronous generator (PMSG)-based wind turbine (WT) has on low-frequency oscillation (LFO) damping. A reduced mathematical model of an interarea system is first established. Then, an auxiliary damping controller is designed using the PMSG active power control loop, enabling the WT to actively support the interarea LFO mitigation. Based on this, the damping torque analysis (DTA) method is applied to explore the contribution of the PMSG-based WT with an auxiliary damping controller to LFO damping enhancement, whose analytical expressions of the damping torque coefficients reveal the impacts of the control parameters and the operation conditions on the system damping characteristics. It is evident that the installation location of the wind power plant (WPP) plays a leading role in determining whether the damping provided by the PMSG controller is positive or negative. Also, the contribution of damping from the PMSG can be improved by tuning the droop coefficient of the PMSG controller properly. The results indicate that the proposed damping control is always helpful in improving the system damping when the wind power penetration increases. Accordingly, analytical conclusions can serve as guidelines for the control design. Case studies of a two-area test system integrated with a PMSG-based wind farm have been conducted to verify the theoretical analysis.
引用
收藏
页数:15
相关论文
共 43 条
[1]   Adaptive LFC Incorporating Modified Virtual Rotor to Regulate Frequency and Tie-Line Power Flow in Multi-Area Microgrids [J].
Abubakr, Hussein ;
Guerrero, Josep M. ;
Vasquez, Juan C. ;
Mohamed, Tarek Hassan ;
Mahmoud, Karar ;
Darwish, Mohamed M. F. ;
Dahab, Yasser Ahmed .
IEEE ACCESS, 2022, 10 :33248-33268
[2]   Comprehensive Review on Renewable Energy Sources in Egypt-Current Status, Grid Codes and Future Vision [J].
Abubakr, Hussein ;
Vasquez, Juan C. ;
Mahmoud, Karar ;
Darwish, Mohamed M. F. ;
Guerrero, Josep M. .
IEEE ACCESS, 2022, 10 :4081-4101
[3]   Maximum penetration level of wind generation considering power system security limits [J].
Ahmadi, H. ;
Ghasemi, H. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (11) :1164-1170
[4]   Resilient Design of Robust Multi-Objectives PID Controllers for Automatic Voltage Regulators: D-Decomposition Approach [J].
Ali, Mahmoud N. ;
Soliman, Mahmoud ;
Mahmoud, Karar ;
Guerrero, Josep M. ;
Lehtonen, Matti ;
Darwish, Mohamed M. F. .
IEEE ACCESS, 2021, 9 :106589-106605
[5]   Impact of Virtual Synchronous Machines on Low-Frequency Oscillations in Power Systems [J].
Baruwa, Muftau ;
Fazeli, Meghdad .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (03) :1934-1946
[6]  
Basu Mayur, 2021, 2021 3rd International Conference on High Voltage Engineering and Power Systems (ICHVEPS), P581, DOI 10.1109/ICHVEPS53178.2021.9601127
[7]  
Chen Zhang, 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM), DOI 10.1109/PESGM.2018.8586438
[8]  
Cuiqi Du, 2021, 2021 China Automation Congress (CAC), P5432, DOI 10.1109/CAC53003.2021.9727428
[9]   CONCEPTS OF SYNCHRONOUS MACHINE STABILITY AS AFFECTED BY EXCITATION CONTROL [J].
DEMELLO, FP ;
CONCORDIA, C .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (04) :316-+
[10]   Damping Torque Analysis of DC Voltage Stability of an MTDC Network for the Wind Power Delivery [J].
Du, Wenjuan ;
Fu, Qiang ;
Wang, Haifeng .
IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (01) :324-338