Online Coupling of Capillary Electrophoresis with Direct Analysis in Real Time Mass Spectrometry

被引:43
作者
Chang, Cuilan [1 ]
Xu, Gege [1 ]
Bai, Yu [1 ]
Zhang, Chengsen [1 ]
Li, Xianjiang [1 ]
Li, Min [1 ]
Liu, Yi [1 ]
Liu, Huwei [1 ]
机构
[1] Peking Univ, Coll Chem & Mol Engn, Beijing Natl Lab Mol Sci,Inst Analyt Chem, Key Lab Bioorgan Chem & Mol Engn,Minist Educ, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; DESORPTION ELECTROSPRAY-IONIZATION; ZONE-ELECTROPHORESIS; AMBIENT CONDITIONS; COATED CAPILLARY; JASMONIC ACID; CE-MS; INTERFACE; OPTIMIZATION;
D O I
10.1021/ac303450v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The online coupling of capillary electrophoresis with ambient direct analysis in real time mass spectrometry (DART-MS) was realized by a coaxial tip interface. The analytes eluted from capillary electrophoresis (CE) were directly ionized by the metastable helium flux produced by DART and transferred into MS for the detection, with which the online separation and simultaneous detection were achieved. The CE-DART-MS can tolerate higher concentrations of detergents and salts than traditional CE-electrospray ionization (ESI)-MS and avoided the difficulties of collecting CE effluent and cleaning the interface, which simplified the experimental procedures and shortened the analysis time. The performance of the technique was successfully verified by capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) using a mixture of 4-aminoantipyrine, zolmitriptan, and quinine. This online technique showed good repeatability with the relative standard deviations (RSDs; n = 5) of 0.56-1.23% for the retention times and 2.01-7.41% for the peak areas. The quantitative analysis of 4-aminoantipyrine was accomplished in the range of 0.01-0.50 mg/mL with the linear correlation coefficient of 0.9995 and limit of detection of 14.7 fmol. Compared with CE-ESI-MS, the ion suppression effects of nonvolatile salts and detergents were efficiently minimized. The signal intensity remained constant when the concentrations reached 100 mM for sodium borate and 30 mM for SDS (in 30 mM sodium borate buffer). In addition, the proposed method was successfully applied to the detection of the endogenous caffeine in Chinese white tea.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 45 条
[1]   An investigation of peak-broadening effects arising when combining CE with MS [J].
Axen, Jakob ;
Axelsson, Bengt-Olof ;
Jornten-Karlsson, Magnus ;
Petersson, Patrik ;
Sjoberg, Per J. R. .
ELECTROPHORESIS, 2007, 28 (18) :3207-3213
[2]   Interfacing Capillary-Based Separations to Mass Spectrometry Using Desorption Electrospray Ionization [J].
Barbula, Griffin K. ;
Safi, Samir ;
Chingin, Konstantin ;
Perry, Richard H. ;
Zare, Richard N. .
ANALYTICAL CHEMISTRY, 2011, 83 (06) :1955-1959
[3]   High-performance liquid chromatography coupled to direct analysis in real time mass spectrometry: Investigations on gradient elution and influence of complex matrices on signal intensities [J].
Beissmann, Susanne ;
Buchberger, Wolfgang ;
Hertsens, Robert ;
Klampfl, Christian W. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) :5180-5186
[4]   Normal phase LC coupled with direct analysis in real time MS for the chiral analysis of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol and jasmonic acid [J].
Chang, Cuilan ;
Zhou, Zhigui ;
Yang, Youyou ;
Han, Yehua ;
Bai, Yu ;
Zhao, Meiping ;
Liu, Huwei .
ELECTROPHORESIS, 2012, 33 (22) :3387-3393
[5]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[6]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[7]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[8]   Investigations on the Coupling of High-Performance Liquid Chromatography to Direct Analysis in Real Time Mass Spectrometry [J].
Eberherr, Walter ;
Buchberger, Wolfgang ;
Hertsens, Robert ;
Klampfl, Christian W. .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5792-5796
[9]   Analysis of aristolochic acids by CE-MS with carboxymethyl chitosan-coated capillary [J].
Fu, Xiaofang ;
Liu, Yi ;
Li, Wei ;
Pang, Nannan ;
Nie, Honggang ;
Liu, Huwei ;
Cai, Zongwei .
ELECTROPHORESIS, 2009, 30 (10) :1783-1789
[10]   Analysis of phospholipids by NACE with on-line ESI-MS [J].
Gao, Fei ;
Zhang, Zhengxiang ;
Fu, Xiaofang ;
Li, Wei ;
Wang, Tao ;
Liu, Huwei .
ELECTROPHORESIS, 2007, 28 (09) :1418-1425