Biomechanical Evaluation of Suture-Augmented Locking Plate Fixation for Proximal Third Fractures of the Olecranon

被引:29
作者
Wild, Jason R. [1 ]
Askam, Brad M. [1 ]
Margolis, David S. [1 ]
Geffre, Christopher P. [1 ]
Krupinski, Elizabeth A. [2 ]
Truchan, Lisa M. [1 ]
机构
[1] Univ Arizona, Dept Orthopaed Surg, Tucson, AZ USA
[2] Univ Arizona, Dept Radiol, Tucson, AZ 85724 USA
关键词
olecranon fracture; suture augmentation; open reduction; locked plating; biomechanical; technique; HUMERAL FRACTURES; TENSION; NAIL;
D O I
10.1097/BOT.0b013e318239273c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To describe a method of suture augmentation of locking plate fixation (PF) of proximal olecranon fractures and to evaluate the biomechanical effectiveness of the suture augmentation using a human cadaveric model. Methods: Six matched pairs of cadaveric elbows were used. Proximal one-third fractures of the olecranon were simulated via a transverse osteotomy. Identical locking PF was performed on each elbow using olecranon locking plates. One elbow of each pair was assigned to suture augmentation of the construct. The choice of left/right specimen for augmentation was performed in an alternating fashion. Augmentation was performed using a no. 2 ultra-high-molecular weight polyethylene-braided suture attaching the triceps to the plate via a modified Krackow stitch. The elbows were mounted into a custom jig and linearly loaded to failure using a hydraulic testing machine. Load to and modes of failure were recorded for each sample. The data were analyzed using the Wilcoxon signed-rank test for nonparametric distributions. Results: Suture augmentation improved the single load-to-failure strength in all pairs. One pair was excluded due to failure of the triceps attachment to the test machine. A median 398 N (P = 0.04 range, 197-633 N) or a median 48% (range, 30%-130%) improvement in strength was seen. The most common mode of failure was loss of fixation of the proximal olecranon fragment. Conclusions: Suture augmentation can significantly increase the single load-to-failure strength of locking PF for proximal olecranon fractures.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 20 条
[1]   Clinical Evaluation of Locking Compression Plate Fixation for Comminuted Olecranon Fractures [J].
Buijze, Geert ;
Kloen, Peter .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (10) :2416-2420
[2]   Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating [J].
Buijze, Geert A. ;
Blankevoort, Leendert ;
Tuijthof, Gabrielle J. M. ;
Sierevelt, Inger N. ;
Kloen, Peter .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (04) :459-464
[3]   METHODS OF FIXATION OF OLECRANON FRACTURES - AN EXPERIMENTAL MECHANICAL STUDY [J].
FYFE, IS ;
MOSSAD, MM ;
HOLDSWORTH, BJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03) :367-372
[4]  
Hak D J, 2000, J Am Acad Orthop Surg, V8, P266
[5]  
HUME MC, 1992, CLIN ORTHOP RELAT R, P229
[6]   Cyclic loading of olecranon fracture fixation constructs [J].
Hutchinson, DT ;
Horwitz, DS ;
Ha, G ;
Thomas, CW ;
Bachus, KN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :831-837
[7]   Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate [J].
Konrad, G. ;
Bayer, J. ;
Hepp, P. ;
Voigt, C. ;
Oestern, H. ;
Kaeaeb, N. ;
Luo, C. ;
Plecko, M. ;
Wendt, K. ;
Koestler, W. ;
Suedkamp, N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A :85-95
[8]  
Kozin S H, 1996, J Shoulder Elbow Surg, V5, P442, DOI 10.1016/S1058-2746(96)80016-4
[9]   The treatment of fractures of the olecranon by longitudinal screw or nail fixation [J].
MacAusland, WR .
ANNALS OF SURGERY, 1942, 116 :293-296
[10]   COMPLICATIONS OF TENSION-BAND WIRING OF OLECRANON FRACTURES [J].
MACKO, D ;
SZABO, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (09) :1396-1401