Adsorption of Doxorubicin on Poly(methyl methacrylate)-Chitosan-Heparin-Coated Activated Carbon Beads

被引:29
作者
Miao, Jianjun [1 ,5 ,6 ]
Zhang, Fuming [2 ,5 ]
Takieddin, Majde [7 ]
Mousa, Shaker [7 ]
Linhardt, Robert J. [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Rensselaer Polytech Inst, Dept Chem & Biol Engn, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Chem & Chem Biol, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Biol, Troy, NY 12180 USA
[4] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[5] Rensselaer Polytech Inst, Ctr Biotechnol & Interdisciplinary Studies, Troy, NY 12180 USA
[6] Rensselaer Polytech Inst, Rensselaer Nanotechnol Ctr, Troy, NY 12180 USA
[7] Albany Coll Pharm, Pharmaceut Res Inst, Albany, NY 12208 USA
基金
美国国家卫生研究院;
关键词
IN-VITRO; CHARCOAL HEMOPERFUSION; DRUG DETOXIFICATION; VENOUS ISOLATION; IONIC LIQUIDS; HEPARIN; BIOCOMPATIBILITY; PERFUSION; CHEMOTHERAPY; COMPOSITES;
D O I
10.1021/la3000137
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Extracorporeal filter cartridges, filled with an activated carbon bead (ACB) adsorbent, have been used for removal of overdosed cancer drugs from the blood. Coatings on adsorbent matrices, poly(methyl methacrylate) (PMMA)/activated carbon bead and PMMA/chitosan/heparin/ACB composites, were tested to improve their biocompatibility and blood compatibility. PMMA coating on ACBs was accomplished in a straightforward manner using a PMMA solution in ethyl acetate. A one-step hybrid coating of ACBs with PMMA-anticoagulant heparin required the use of acetone and water co-solvents. Multilayer coatings with three components, PMMA, chitosan, and heparin, involved three steps: PMMA was first coated on ACBs; chitosan was then coated on the PMMA-coated surface; and finally, heparin was covalently attached to the chitosan coating. Surface morphologies were studied by scanning electron microscopy. X-ray photoelectron spectroscopy confirmed the -SO3- group. Adsorption, of a chemotherapy drug (doxorubicin) from both water and phosphate-buffered saline, by the coated ACBs was examined. The adsorption isotherm curves were fitted using the Freundlich model. The current adsorption system might find potential applications in the removal of high-dose regional chemotherapy drugs while maintaining high efficiency, biocompatibility, and blood compatibility.
引用
收藏
页码:4396 / 4403
页数:8
相关论文
共 19 条
  • [1] Doxorubicin: The Good, the Bad and the Ugly Effect
    Carvalho, Cristina
    Santos, Renato X.
    Cardoso, Susana
    Correia, Sonia
    Oliveira, Paulo J.
    Santos, Maria S.
    Moreira, Paula I.
    [J]. CURRENT MEDICINAL CHEMISTRY, 2009, 16 (25) : 3267 - 3285
  • [2] Adsorption behavior of epirubicin hydrochloride on carboxylated carbon nanotubes
    Chen, Zhe
    Pierre, Dramou
    He, Hua
    Tan, Shuhua
    Chuong Pham-Huy
    Hong, Hao
    Huang, Jilong
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 405 (1-2) : 153 - 161
  • [3] CRITICAL EVALUATION OF PRINCIPLES GOVERNING ADVANTAGES OF INTRA-ARTERIAL INFUSIONS
    ECKMAN, WW
    PATLAK, CS
    FENSTERMACHER, JD
    [J]. JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1974, 2 (03): : 257 - 285
  • [4] Changes in cultured endothelial cell glycosaminoglycans under hyperglycemic conditions and the effect of insulin and heparin
    Han, Juying
    Zhang, Fuming
    Xie, Jin
    Linhardt, Robert J.
    Hiebert, Linda M.
    [J]. CARDIOVASCULAR DIABETOLOGY, 2009, 8 : 46
  • [5] Comprehensive biocompatibility testing of a new PMMA-HA bone cement versus conventional PMMA cement in vitro
    Jäger, M
    Wilke, A
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2003, 14 (11) : 1283 - 1298
  • [6] Development of isolated hepatic perfusion for patients who have unresectable hepatic malignancies
    Jones, Adriana
    Alexander, H. Richard, Jr.
    [J]. SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2008, 17 (04) : 857 - +
  • [7] A validated assay for measuring doxorubicin in biological fluids and tissues in an isolated lung perfusion model:: matrix effect and heparin interference strongly influence doxorubicin measurements
    Kümmerle, A
    Krueger, T
    Dusmet, M
    Vallet, C
    Pan, Y
    Ris, HB
    Decosterd, LA
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (03) : 475 - 494
  • [8] Effect of sodium thiosulfate on cisplatin removal with complete hepatic venous isolation and extracorporeal charcoal hemoperfusion: A pharmacokinetic evaluation
    Kusunoki, N
    Ku, Y
    Tominaga, M
    Iwasaki, T
    Fukumoto, T
    Muramatsu, S
    Sugimoto, T
    Tsuchida, S
    Takamatsu, M
    Suzuki, Y
    Kuroda, Y
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2001, 8 (05) : 449 - 457
  • [9] In vitro biocompatibility of chitosan porous skin regenerating templates (PSRTs) using primary human skin keratinocytes
    Lim, C. K.
    Yaacob, N. S.
    Ismail, Z.
    Halim, A. S.
    [J]. TOXICOLOGY IN VITRO, 2010, 24 (03) : 721 - 727
  • [10] Percutaneous pelvic perfusion with extracorporeal chemofiltration for advanced uterine cervical carcinoma
    Maruo, Takeshi
    Motoyama, Satoru
    Hamana, Shinya
    Yoshida, Shigeki
    Ohara, Noriyuki
    Yamasaki, Mineo
    Ku, Yonson
    [J]. SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2008, 17 (04) : 843 - +