Suture Button Fixation Versus Syndesmotic Screws in Supination-External Rotation Type 4 Injuries: A Cost-Effectiveness Analysis

被引:45
作者
Neary, Kaitlin C. [1 ,2 ]
Mormino, Matthew A. [1 ,2 ]
Wang, Hongmei [1 ,2 ]
机构
[1] Univ Nebraska, Med Ctr, Omaha, NE USA
[2] Univ Nebraska, Med Ctr, Dept Orthopaed Surg & Rehabil, 981080 Nebraska Med Ctr, Omaha, NE 68198 USA
关键词
syndesmotic injury; suture button; cost-effectiveness analysis; economic and decision analysis; UNSTABLE ANKLE FRACTURES; TIBIOFIBULAR SYNDESMOSIS; FUNCTIONAL OUTCOMES; TIGHTROPE FIXATION; HEALTH; REMOVAL; TRIAL; RECOMMENDATIONS; OSTEOARTHRITIS; REDUCTION;
D O I
10.1177/0363546516664713
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. Purpose: This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Study Design: Economic and decision analysis; Level of evidence, 2. Methods: Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Results: Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. Conclusion: This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.
引用
收藏
页码:210 / 217
页数:8
相关论文
共 34 条
[1]   A prospective cost analysis following operative treatment of unstable ankle fractures - 30 patients followed for 1 year [J].
Bhandari, M ;
Sprague, S ;
Ayeni, OR ;
Hanson, BP ;
Moro, JK .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01) :100-105
[2]   Removal of the syndesmotic screw after the surgical treatment of a fracture of the ankle in adult patients does not affect one-year outcomes A RANDOMISED CONTROLLED TRIAL [J].
Boyle, M. J. ;
Gao, R. ;
Frampton, C. M. A. ;
Coleman, B. .
BONE & JOINT JOURNAL, 2014, 96B (12) :1699-1705
[3]   Incidence of hardware-related pain and its effect on functional outcomes after open reduction and internal fixation of ankle fractures [J].
Brown, OL ;
Dirschl, DR ;
Obremskey, WT .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (04) :271-274
[5]   Transosseous Fixation of the Distal Tibiofibular Syndesmosis: Comparison of an Interosseous Suture and Endobutton to Traditional Screw Fixation in 50 Cases [J].
Cottom, James M. ;
Hyer, Christopher F. ;
Philbin, Terrence M. ;
Berlet, Gregory C. .
JOURNAL OF FOOT & ANKLE SURGERY, 2009, 48 (06) :620-630
[6]   Injuries to the tibiofibular syndesmosis [J].
Dattani, R. ;
Patnaik, S. ;
Kantak, A. ;
Srikanth, B. ;
Selvan, T. P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (04) :405-410
[7]   Evidence on the construct validity of the Health Utilities Index Mark 2 and Mark 3 in patients with chronic kidney disease [J].
Davison, Sara N. ;
Jhangri, Gian S. ;
Feeny, David H. .
QUALITY OF LIFE RESEARCH, 2008, 17 (06) :933-942
[8]   Outcomes of Suture Button Repair of the Distal Tibiofibular Syndesmosis [J].
DeGroot, Henry ;
Al-Omari, Ali A. ;
El Ghazaly, Sherif Ahmed .
FOOT & ANKLE INTERNATIONAL, 2011, 32 (03) :250-256
[9]   Flexible stabilization of the distal tibiofibular syndesmosis: clinical and biomechanical considerations: a review of the literature [J].
den Daas, Annick ;
van Zuuren, Wouter J. ;
Pelet, Stephane ;
van Noort, Arthur ;
van den Bekerom, Michel P. J. .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2012, 7 (03) :123-129
[10]   Outcome after Unstable Ankle Fracture: Effect of Syndesmotic Stabilization [J].
Egol, Kenneth A. ;
Pahk, Brian ;
Walsh, Michael ;
Tejwani, Nirmal C. ;
Davidovitch, Roy I. ;
Koval, Kenneth J. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (01) :7-11