Tear-film dynamics by combining double-pass images, pupil retro-illumination, and contrast sensitivity

被引:5
作者
Benito, Antonio [1 ]
Bueno, Juan M. [1 ]
Perez, Guillermo M. [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Inst Univ Invest Opt & Nanofis, Campus Espinardo,Ed 34, E-30100 Murcia, Spain
基金
欧洲研究理事会;
关键词
FUNCTIONAL VISUAL-ACUITY; WAVE-FRONT SENSOR; OPTICAL COHERENCE TOMOGRAPHY; POINT-SPREAD FUNCTION; DRY EYE DISEASE; BREAK-UP; MEASUREMENT SYSTEM; OCULAR SURFACE; QUALITY; ABERRATIONS;
D O I
10.1364/JOSAA.36.00B138
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Tear-film dynamics were analyzed by a synchronizing recording of double-pass (DP) and pupil retro-illumination (RI) images with contrast sensitivity (CS) measurements. Simultaneous DP and RI images were acquired in three subjects wearing contact lenses while keeping the eye open. Changes in contrast sensitivity for an 18 c/deg green grating were also estimated. From the DP retinal images, the effect of the tear film is described through the objective scattering index (OSI). This presented a negative correlation with the increase in CS during tear-film deterioration (as observed by RI imaging). These results show a relationship between visual outcome degradation due to tear-film breakup and the increase in intraocular scattering. This work shows a combined methodology for the evaluation of tear-film dynamics. (C) 2019 Optical Society of America
引用
收藏
页码:B138 / B142
页数:5
相关论文
共 46 条
  • [1] Diagnosing dry eye with dynamic-area high-speed videokeratoscopy
    Alonso-Caneiro, David
    Turuwhenua, Jason
    Iskander, D. Robert
    Collins, Michael J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (07)
  • [2] An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts
    Artal, Pablo
    Benito, Antonio
    Perez, Guillermo M.
    Alcon, Encarna
    De Casas, Alvaro
    Pujol, Jaume
    Marin, Jose M.
    [J]. PLOS ONE, 2011, 6 (02):
  • [3] Quantitative Analysis of Tear Film Fluorescence and Discomfort During Tear Film Instability and Thinning
    Begley, Carolyn
    Simpson, Trefford
    Liu, Haixia
    Salvo, Eliza
    Wu, Ziwei
    Bradley, Arthur
    Situ, Ping
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2645 - 2653
  • [4] Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes
    Benito, Antonio
    Perez, Guillermo M.
    Mirabet, Sandra
    Vilaseca, Meritxell
    Pujol, Jaume
    Marin, Jose M.
    Artal, Pablo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) : 1481 - 1487
  • [5] Bron AJ, 2007, OCUL SURF, V5, P108
  • [6] Impact of scatter on double-pass image quality and contrast sensitivity measured with a single instrument
    Bueno, Juan M.
    Perez, Guillermo
    Benito, Antonio
    Artal, Pablo
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12): : 4841 - 4849
  • [7] THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME
    CHO, P
    DOUTHWAITE, W
    [J]. OPTOMETRY AND VISION SCIENCE, 1995, 72 (01) : 17 - 22
  • [8] Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument
    Díaz-Doutón, F
    Benito, A
    Pujol, J
    Arjona, M
    Güell, JL
    Artal, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (04) : 1710 - 1716
  • [9] Strip meniscometry: A new and simple method of tear meniscus evaluation
    Dogru, Murat
    Ishida, Katsushi
    Matsumoto, Yukihiro
    Goto, Eiki
    Ishioka, Misaki
    Kojima, Takashi
    Goto, Tateki
    Saeki, Megumi
    Tsubota, Kazuo
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (05) : 1895 - 1901
  • [10] Double lateral shearing interferometer for the quantitative measurement of tear film topography
    Dubra, A
    Paterson, C
    Dainty, C
    [J]. APPLIED OPTICS, 2005, 44 (07) : 1191 - 1199